ATB Mining Cable with Abrasion Resistant Rubber Sheath and Copper Conductor for 1.8/3kV Applications

Basis eigenschappen
Plaats van herkomst: Hebei, China
Merknaam: Minfeng
Certificering: ISO,CE,IEC,TUV,KEMA
Modelnummer: Rubberen Kabel
Handelsgoederen
Minimale bestelhoeveelheid: 100
Prijs: 0.1-5
Betalingsvoorwaarden: L/C, T/T
Leveringscapaciteit: 100 km/week
Specificaties
Outer Sheath: Slijtvaste rubbersamenstelling Conductor Type: Koper
Insulation: Rubbercompound Type 3GI3 Temperature Rating: -40 ℃ -80 ℃
Voltage Rating: Nominale spanning 1,8/3 kV | 3,6/6 kV | 6/10 kV Transport Package: Houten stalen trommel
Standards: VDE 0250 deel 813, VDE 0295, EN 60228
Productomschrijving
(N)TSCGECEWOU ATB Mining Cable with Check Ground Conductor 1.8/3kV 3.6/6kV 6/10kV
ATB Mining Cable product photo showing industrial cable construction
Product Overview

Flexible cable designed for energy supply to heavy mobile equipment such as drag lines, shovels, dredges and drills. Engineered to withstand extreme mechanical stresses and abrasion during trailing operation in opencast mines. Features special construction with additional ground check conductor and is suitable for both indoor and outdoor applications.

Rated Voltage 1.8/3kV | 3.6/6kV | 6/10kV
Size Range 25-185mm²
Conductor Material Copper
Insulation Material Rubber compound Type 3GI3
Working Temperature -40℃ to +80℃
Jacket Material Abrasion resistant rubber compound
Application Industrial
Type Medium Voltage
Technical Characteristics
Voltage Rating Uo/U 1.8/3kV | 3.6/6kV | 6/10kV
Test Voltage 1.8/3kV: 6kV | 3.6/6kV: 11kV | 6/10kV: 17kV
Ambient Temperature Fixed: -40ºC to +80°C
Flexed: -25°C to +80°C
Max Short Circuit Temperature +250°C
Minimum Bending Radius Fixed: 6 x overall diameter
Flexed: 10 x overall diameter
Cable Construction
  • Phase Conductor: Class 5 tinned copper conductor
  • Insulation: Rubber compound Type 3GI3
  • Semi-Conductive Layers: Semi-conductive tape over the conductor and inner/outer semi-conductive rubber layer on the insulation from 3.6/6kV
  • Earth Conductor: Individual copper braid, 2 x copper earth conductors, 1 x copper checking earth wiring conductor
  • Central Filler: Rubber compound on a textile polyester support
  • Inner Sheath: Abrasion resistant rubber compound
  • Anti-Torsion Braid: Polyester braid between the inner and outer sheath
  • Outer Sheath: Abrasion resistant rubber compound
Standards Compliance

VDE 0250 Part 813, VDE 0295, EN 60228

Flame Retardant according to IEC/EN 60332-1-2

Technical Specifications
Voltage (kV) No. of Cores Nominal Cross Section (mm²) Conductor Diameter (mm) Min Overall Diameter (mm) Max Overall Diameter (mm) Max Tensile Load (N) Nominal Weight (kg/km)
1.8/3 3+2+1 25 6.8 38.2 42.3 1125 2530
1.8/3 3+2+1 35 7.8 39.7 44 1575 2930
1.8/3 3+2+1 50 9.4 42.7 47.2 2250 3540
1.8/3 3+2+1 70 11.2 48.1 53 3150 4730
1.8/3 3+2+1 95 12.7 53 58.3 4257 5930
1.8/3 3+2+1 120 14.4 57.4 63.1 5400 7270
1.8/3 3+2+1 150 16.3 63.8 70 6750 8920
1.8/3 3+2+1 185 17.6 65.6 71.9 8325 10220
3.6/6 3+2+1 25 6.8 45.4 50.1 1125 3300
3.6/6 3+2+1 35 7.8 46.7 51.5 1575 3710
3.6/6 3+2+1 50 9.4 51.5 56.7 2250 4600
3.6/6 3+2+1 70 11.2 55.2 60.7 3150 5710
3.6/6 3+2+1 95 12.7 58.9 64.8 4257 6820
3.6/6 3+2+1 120 14.4 65.1 71.4 5400 8540
3.6/6 3+2+1 150 16.3 69.9 76.3 6750 9890
6/10 3+2+1 25 6.8 48.1 53 1125 3640
6/10 3+2+1 35 7.8 49.5 54.6 1575 4070
6/10 3+2+1 50 9.4 54.2 59.7 2250 4980
6/10 3+2+1 70 11.2 57.9 63.6 3150 6070
6/10 3+2+1 95 12.7 61.6 67.7 4257 7280
6/10 3+2+1 120 14.4 67.9 74.4 5400 9070
Algemene rating
5.0
★★★★★
★★★★★
Gebaseerd op 50 recente beoordelingen
vijfsterren
100%
4 sterren
0
3 sterren
0
2 sterren
0
1 ster
0
All Reviews
  • G
    Grev lithium
    India Apr 26.2024
    ★★★★★
    ★★★★★
    The LSZH (Low Smoke Zero Halogen) properties of these cables are exactly as advertised. They performed exceptionally well during our fire safety compliance audit.
  • I
    IBRAHIM CALVA
    Equatorial Guinea Mar 8.2020
    ★★★★★
    ★★★★★
    Our field technicians have specifically requested this brand because the cable is easy to strip and pull through conduits, saving us significant man-hours on-site.