Power Cable YAXV Multi-core With Insulated Ground Conductor NA2XY 3x150 SM
| Cable Length: | 100m-5000m | Sheath material: | PVC |
| Trademark: | Minfeng Cable Group | Voltage: | 0.6/1kV |
| Manufacturer: | Minfeng Factory | Insulation: | XLPE |
| Standard Compliance: | IEC 60502 | ||
| High Light: | XLPE insulated power cable with ground conductor,NA2XY multi-core power cable,YAXV power cable 3x150 SM |
||
XLPE insulated, single core underground cable with aluminium conductor designed for industrial applications with high performance specifications.
This cable, featuring very low dielectric loss, is used indoor, in cable ducts and in industrial plants or switching stations where mechanical damage is not anticipated. Suitable for comparatively high ambient temperature due to high maximum permissible conductor temperature.
| Rated Cross-section | Overall Diameter of Cable | Net Weight (Approx.) | Conductor DC Resistance at 20°C | Current Carrying Capacity |
|---|---|---|---|---|
| mm² | mm | kg | ohm/km | ampere 1 | ampere 2 |
| 1 Core | ||||
| 1 x 16 | 9.7 | 105 | 1.91 | - | - |
| 1 x 25 | 10.9 | 154 | 1.20 | - | - |
| 1 x 35 | 12.1 | 195 | 0.868 | 137 | 131 |
| 1 x 50 | 13.8 | 250 | 0.641 | 163 | 161 |
| 1 x 70 | 15.5 | 325 | 0.443 | 201 | 205 |
| 1 x 95 | 17.7 | 434 | 0.320 | 240 | 253 |
| 1 x 120 | 19.6 | 521 | 0.253 | 274 | 296 |
| 1 x 150 | 21.7 | 640 | 0.206 | 308 | 341 |
| 1 x 185 | 24.1 | 785 | 0.164 | 350 | 395 |
| 1 x 240 | 27.2 | 1018 | 0.125 | 408 | 475 |
| 2 Cores | ||||
| 2x10 | 14.4 | 292 | 3.080 | - | - |
| 2x16 | 16.6 | 392 | 1.91 | - | - |
| 2x25 | 21.0 | 608 | 1.20 | 111 | 100 |
| 2x35 | 23.4 | 168 | 0.868 | 132 | 122 |
| 2x50 | 27.0 | 1016 | 0.641 | 157 | 147 |
| 3 Cores | ||||
| 3x10 | 15.4 | 338 | 3.080 | - | - |
| 3x16 | 17.6 | 446 | 1.91 | - | - |
| 3x25 | 22.3 | 678 | 1.20 | 111 | 100 |
| 3x35 | 24.9 | 864 | 0.868 | 132 | 122 |
| 3x50 | 28.8 | 1147 | 0.641 | 157 | 147 |
| 3x70 | 32.7 | 1507 | 0.443 | 195 | 180 |
| 3x95 | 37.3 | 1992 | 0.32 | 233 | 232 |
| 3x120 | 41.2 | 2398 | 0.253 | 266 | 270 |
| 3x150 | 46.0 | 2991 | 0.206 | 299 | 308 |
| 3x185 | 51.2 | 3688 | 0.164 | 340 | 357 |
| 3x240 | 58.0 | 4786 | 0.125 | 401 | 435 |
| 4 Cores | ||||
| 4 x 25 | 24.7 | 834 | 1.20 | 111 | 100 |
| 4 x 35 | 27.6 | 1065 | 0.868 | 132 | 122 |
| 4 x 50 | 31.9 | 1406 | 0.641 | 157 | 147 |
| 4 x 70 | 36.4 | 1868 | 0.443 | 195 | 180 |
| 4 x 95 | 41.4 | 2457 | 0.320 | 233 | 232 |
| 4 x 120 | 45.7 | 2950 | 0.253 | 266 | 270 |
| 4 x 150 | 52 | 3810 | 0.206 | 299 | 308 |
| 4 x 185 | 57.7 | 4668 | 0.164 | 340 | 357 |
| 4 x 240 | 65.6 | 6109 | 0.125 | 401 | 435 |
| 5 Cores | ||||
| 5 x 16 | 23.1 | 738 | 1.91 | - | - |
| 5 x 25 | 26.9 | 992 | 1.20 | 111 | 100 |
| 5 x 35 | 30.4 | 1294 | 0.868 | 132 | 122 |
| 5 x 50 | 35.4 | 1734 | 0.641 | 157 | 147 |
| 5 x 70 | 40.3 | 2289 | 0.443 | 195 | 180 |
| 5 x 95 | 46.5 | 3097 | 0.320 | 233 | 232 |
- Min. Bending radius: 15xD
- Max operating temperature: 90°C
- Max short circuit temperature: 250°C
- Rated voltage Uo/U: 0.6/1 KV
- AC test voltage: 3.5 KV
- Flame propagation test on single cable EN 60332-1