150 Sq Mm Single Core Armoured Cable XLPE Insulated Steel Power Cable For Power Distribution
| Productname: | Armoured Cable | Standard: | AISI, ASTM, BS, DIN, GB, JIS |
| Cabletype: | Armoured | Sheathmaterial: | PVC Or PE |
| Cablesize: | Varies From 1.5mm² To 1000mm² | Conductormaterial: | Copper Or Aluminum |
| Flameretardant: | Yes/No | Insulationmaterial: | PVC, XLPE, Or Rubber |
| High Light: | 150 Sq Mm Armoured Cable,Single Core Armoured Cable,Armoured XLPE Insulated Power Cable |
||
| Product Name | Copper core or aluminum core XLPE insulated PVC sheathed power cable Copper core or aluminum core XLPE insulated steel tape armoured PVC sheathed power cable Copper core or aluminum core XLPE insulated steel wire armoured PVC sheathed power cable |
|---|---|
| Rated Voltage | 0.6/1kv, 1.8/3kv, 3.6/6kv, 6/10kv, 8.7/15kv, 12/20kv, 21/35kv, 26/35kv |
| Standard | B/T12706-2008, GB/T12703-200, IEC60502-1-1997 |
| Model | YJV, YJLV, YJV22, YJLV22, YJV32, YJLV32, YJV42, YJLV42 |
| Armoured | Steel tape armored, steel wire armored, Double of galvanized steel tape or galvanized steel wire for three core power cable, Double of aluminium tape or aluminium wire for single power cable |
| Number of cores | Single core, 2 cores, 3 cores, 4 cores, 5 cores, 3+1 cores, 3+2 cores, 4+1 cores, etc. |
| Common size | 1mm², 1.5mm², 2.5mm², 4mm², 6mm², 10mm², 16mm², 25mm², 35mm², 50mm², 70mm², 95mm², 120mm², 150mm², 185mm², 240mm², 300mm², 400mm², 500mm², 630mm², 800mm², 1000mm², etc. |
| Types | Ordinary type, flame-retardant type, fire-resistant type, low-smoke halogen-free type |
| Application | Power distribution engineering, power transmission engineering, electromechanical and hydropower installation engineering, power transmission, power supply installation system, control system, etc. |
Power cables are cables used to transmit and distribute electrical energy. Power cables are often used in urban underground power grids, power station outgoing lines, internal power supply in industrial and mining enterprises, and underwater transmission lines across rivers.
YJV cables are the backbone cables in power transmission. They are typically found in urban underground passages (underground manhole covers) or buried underground. Construction teams often cut off power cables during construction, which can cause large-scale power outages.
- The minimum bending radius when laying the cable should not be less than 10 times the outer diameter of the cable.
- YJV/YJLV cables are laid indoors, in channels and pipes, and can also be buried in loose soil that cannot bear external forces.
- YJV22/YJLV22 cables are laid underground and can withstand external mechanical forces, but cannot withstand large tensile forces.
- Special tools should be used for cable laying, such as pay-off racks, guide rollers, etc., to prevent mechanical damage during the laying process and keep away from heat sources.
- When laying the cable through pipes, the inner diameter of the pipe should not be less than 1.5 times the outer diameter of the cable. It is forbidden to squeeze the cable when passing through the pipe. The total area of the cable should not exceed 40% of the total area of the pipe.
-
AInternational shipping can be rough, but the reinforced wooden drumming used by this supplier ensured the cable arrived in pristine condition without any kinks.
-
MIn an industry plagued by shortages, this manufacturer’s ability to maintain a steady lead time is a massive asset to our supply chain.
-
GThe LSZH (Low Smoke Zero Halogen) properties of these cables are exactly as advertised. They performed exceptionally well during our fire safety compliance audit.