33kv 11kv 3 Core XLPE Insulated Submarine Power Cable 95mm2 Medium Voltage
Basic Properties
Place of Origin:
Hebei, China
Brand Name:
Minfeng
Certification:
ISO,CE,IEC,TUV,KEMA
Model Number:
Submarine Cable
Trading Properties
Minimum Order Quantity:
100
Price:
0.1-5
Payment Terms:
L/C,T/T
Supply Ability:
100KM/Week
Specifications
| Core Mark: | Number Or Color Strip | Halogen Free: | Available |
| Type: | YJV YJV22 YJV32 | Cores No: | 1-5 |
| Flame Retardant: | Available | Conductor Material: | Copper Or Al-alloy |
| Outer Sheath Color: | Black Or As Per Required | Insulation: | XLPE |
| High Light: | 33kv XLPE Submarine Cable,11kv 3 Core XLPE Cable,Submarine Power Cable |
||
Product Description
Submarine Power Cable 95 Mm² 150mm 400mm Medium Voltage 11kv 33kv Electrical Cables 3 Core XLPE
Product Overview
High-quality medium voltage power cables designed for submarine applications, power distribution engineering, and industrial power transmission systems.
Conductor Material
Aluminium or Copper
Insulation Material
XLPE/PVC
Jacket
PVC
Application
Power Station
Type
Medium Voltage
Place of Origin
Hebei, China
Model Number
YJV22 YJV YJLV
Brand Name
Minfeng
Armour
SWA STA AWA DBT
Standard
BS IEC ASTM DIN
Certificate
ISO9001, ISO14001, OHSAS18001, CCC
Rated Voltage
1-35KV
Sheath
PVC (Polyvinyl Chloride), flame retardant PVC, PE, LSOH, HFFR
Cross Section
1.5mm²-800mm²
Core
1-5 Core
Product Images
Technical Specifications
| Product Name | Copper core or aluminum core XLPE insulated PVC sheathed power cable Copper core or aluminum core XLPE insulated steel tape armoured PVC sheathed power cable Copper core or aluminum core XLPE insulated steel wire armoured PVC sheathed power cable |
|---|---|
| Rated Voltage | 0.6/1kv 1.8/3kv 3.6/6kv 6/10kv 8.7/15kv 12/20kv 21/35kv 26/35kv |
| Standard | B/T12706-2008, GB/T12703-200, IEC60502-1-1997 |
| Model | YJV YJLV YJV22 YJLV22 YJV32 YJLV32 YJV42 YJLV42 |
| Armoured | Steel tape armored, steel wire armored, Double of galvanized steel tape or galvanized steel wire for three core power cable, Double of aluminium tape or aluminium wire for single power cable |
| Number of Cores | Single core, 2 cores, 3 cores, 4 cores, 5 cores, 3+1 cores, 3+2 cores, 4+1 cores, etc. |
| Common Size | 1mm², 1.5mm², 2.5mm², 4mm², 6mm², 10mm², 16mm², 25mm², 35mm², 50mm², 70mm², 95mm², 120mm², 150mm², 185mm², 240mm², 300mm², 400mm², 500mm², 630mm², 800mm², 1000mm², etc. |
| Types | Ordinary type, flame-retardant type, fire-resistant type, low-smoke halogen-free type |
| Application | Power distribution engineering, power transmission engineering, electromechanical and hydropower installation engineering, power transmission, power supply installation system, control system, etc. |
XLPE Insulated Power Cable
Power cables are cables used to transmit and distribute electrical energy. Power cables are often used in urban underground power grids, power station outgoing lines, internal power supply in industrial and mining enterprises, and underwater transmission lines across rivers.
YJV cables are the backbone cables in power transmission. They are usually found in urban underground passages (underground manhole covers) or buried underground. Construction teams often cut off the power cables during construction and cause large-scale power outages.
Installation Precautions
- The minimum bending radius when laying the cable is not less than 10 times the outer diameter of the cable.
- YJV / YJLV cables are laid indoors, in channels and pipes, and can also be buried in loose soil, which cannot bear external forces.
- The YJV22 / YJLV22 cables are laid underground and can withstand external mechanical forces, but cannot withstand large tensile forces.
- Special tools should be used for cable laying, such as pay-off racks, guide rollers, etc., to prevent mechanical damage during the laying process and keep away from heat sources.
- When laying the cable through the pipe, the inner diameter of the pipe should not be less than 1.5 times the outer diameter of the cable. It is forbidden to squeeze the cable when passing through the pipe. The total area of the cable should not exceed 40% of the total area of the pipe.
Additional Documentation
Overall Rating
5 star
100%
4 star
0
3 star
0
2 star
0
1 star
0
All Reviews
-
AThe export team provided real-time tracking and handled all the customs documentation flawlessly. A very smooth procurement experience.
-
MIn an industry plagued by shortages, this manufacturer’s ability to maintain a steady lead time is a massive asset to our supply chain.
-
SWe’ve been ordering from this factory for three years. The consistency between batches is incredible; the quality of the first shipment matches the hundredth