logo

Aluminum Cable for Underground Distribution (DRS) Low Voltage XLPE 600V 90C 2+1 1+1 6 AWG

Basic Properties
Place of Origin: Hebei, China
Brand Name: Minfeng
Certification: ISO,CE,IEC,TUV,KEMA
Model Number: ABC Cable
Trading Properties
Minimum Order Quantity: 100m
Price: 0.1-5
Payment Terms: L/C,T/T
Supply Ability: 100KM/Week
Specifications
Standard: IEC EN Manufacturer: Minfeng Cable Group
Package Length: 1000m Length: Customized Meters
Usage: Power Distribution Production Time: 10days
Conductor Material: Aluminum
High Light:

Low Voltage XLPE Aluminum Cable

,

Underground Distribution Aluminum Cable

,

600V 90C 6 AWG ABC Cable

Product Description
Key Specifications
  • Rated Voltage0.6 kV / 600 V
  • Available Sizes6 AWG, 8 AWG, 4 AWG, 2 AWG, 1/0 AWG
  • Conductor MaterialAluminum
  • Insulation MaterialXLPE
  • Working Temperature90 °C
  • ApplicationUnderground
  • TypeLow Voltage
  • Number of Cores1+1, 2+1
  • Model Number1+1 / 2+1
  • ColorBlack (phase) / White (neutral)
  • CertificationISO9001 / CCC
  • Brand NameOEM
  • Place of OriginHebei, China
General Description

This cable consists of one, two, or three conductors of hard aluminum 1350, each individually insulated with black cross-linked polyethylene (XLPE). The conductors are joined together with a neutral conductor of hard aluminum 1350 insulated with white cross-linked polyethylene (XLPE).

Specifications
  • CFE E1000-02 — Underground cables for 600 V with cross-linked polyethylene insulation.
Main Applications
  • Low-voltage underground electrical power distribution systems.
  • Installation in conduits or direct burial.
  • Permanent or temporary electrical installations for general lighting.
Aluminum DRS low voltage XLPE underground distribution cable with black phase conductors and white neutral conductor
Features
  • Maximum operating voltage: 600 V.
  • Maximum conductor operating temperature: 90 °C.
  • Hard aluminum 1350 conductors in concentric stranding, with cross-sections from 13.30 to 253.0 mm² (6 AWG to 500 kcmil).
  • Cross-linked polyethylene (XLPE) conductor insulation; phase conductors are black and the neutral conductor is white.
Technical Parameters
Number of ConductorsPhase ConductorNeutral ConductorApprox. Total Weight (kg/100m)Current-Carrying Capacity* (A) at 75 °C
Size (AWG/kcmil)Nominal Area (mm²)Number of StrandsNominal Insulation Thickness (mm)Size (AWG/kcmil)Nominal Area (mm²)Number of StrandsNominal Insulation Thickness (mm)
1613.371.14————760
1613.371.141322032648
1421.271.52————1178
1421.271.522123134162
1233.671.52————15103
2233.671.5244358—82—
2421.271.5239354—82—
11/053.5192.03————23136
2233.671.5261384—108—
12/067.4192.03————28156
13/085.0192.03————34178
21/053.5192.03923125—142—
1300152.0372.41————57252
1350177.0372.41————65276
34/0107192.03240—220———
1500253372.41————89338

Note: Dimensions and weights are subject to manufacturing tolerances. *Current-carrying capacity is based on Table B.310.15(B)(2)(7) for an electrical conduit in NOM-001-SEDE, for an ambient soil temperature of 20 °C, relative humidity of 90%, load factor of 100%, and affected by the number of conductors.

Cross-sectional view of DRS aluminum XLPE insulated low voltage underground distribution cable showing phase and neutral conductors
Overall Rating
5.0
★★★★★
★★★★★
Based on 50 reviews recently
5 star
100%
4 star
0
3 star
0
2 star
0
1 star
0
All Reviews
  • S
    Savvon Maksymchuk
    Ukraine Nov 10.2023
    ★★★★★
    ★★★★★
    We’ve been ordering from this factory for three years. The consistency between batches is incredible; the quality of the first shipment matches the hundredth