logo

N2XS(F)2Y N2XS(FL)2Y 1x240RM/25 1x300 RM/25 6/10KV 12/20KV 18/30KV AC Cable for

Basic Properties
Place of Origin: Hebei, China
Brand Name: Minfeng
Certification: ISO,CE,IEC,TUV,KEMA
Model Number: N2XS(F)2Y N2XS(FL)2Y
Trading Properties
Minimum Order Quantity: 100m
Price: 0.1-5
Payment Terms: L/C,T/T
Supply Ability: 100KM/Week
Specifications
Conductor Material: Copper Or Aluminum Sample: Free
Cable Application: Industrial Corporation: Minfeng Group
Cable Type: XLPE Insulated Power Cable No Of Core: 1
Drum Length: 500m Or As Per Request Maximum operating temperature: 90°C
Transport Package: Wooden Steel Drum
High Light:

XLPE insulated power cable 6/10KV

,

N2XS(F)2Y AC cable 12/20KV

,

N2XS(FL)2Y power cable 18/30KV

Product Description
N2XS(F)2Y N2XS(FL)2Y 1x240RM/25 1x300 RM/25 6/10KV 12/20KV 18/30KV AC Cable
Product Overview

Medium voltage single core 12/20 kV 1x240/50mm² NA2XS(FL)2Y cable designed for reliable power distribution in various industrial applications.

Key Specifications
Type Insulated
Rated Voltage 12/20 kV
Conductor Material Aluminium
Insulation Material XLPE
Conductor Type Stranded
Application Underground
Model Number NA2XS(FL)2Y cable
Brand Name Minfeng
Application

Medium voltage power cable for static application in ground, within and outside facilities, outdoor, in cable canals, in dry areas or in water. PE sheath secures increased mechanical resistance during and after laying. Due to its very low factor of dielectric loss, which remains constant over its entire operating lifetime, and owing to excellent insulation property of XLPE-material, firmly longitudinally spliced with inner and external screen of semi-conductive material (extruded in one process), the cable has a high operating reliability.

Used in transformer stations, switching blocks, in electric power plants and industrial plants. To avoid the effects of external impact, the adhering semi-conductive layer extruded between conductor and insulation, along with concentric copper conductor, secures restriction of electric field and resistance to partial discharges.

N2XS(F)2Y N2XS(FL)2Y medium voltage power cable construction and design
Standards Compliance
  • HRN HD 620 S1
  • IEC 60502-2
  • DIN VDE 0276 part 620
Cable Construction
Conductor Al round conductor, multi wire stranded compacted (RM), class 2
Inner Screen Extruded semi-conductive skin on conductor
Insulation XLPE (cross-linked polyethylene) compound DIX 8
External Screen Extruded semi-conductive skin on insulation
Concentric Conductor Copper wires and copper tape
Separating Tape
Sheath Rigid PE (polyethylene) compound DMP 2
Sheath Color Black
Technical Specifications
Installation Temperature -20°C to +70°C
Max Operating Temperature +90°C
Short Circuit Temperature Up to 250°C (max 5s)
Minimal Bending Radius 15D
Fire Behavior Halogen-free, not self-extinguishing
Technical Data Table
Dimensions - cores x cross-section Construction External Diameter Min (mm) External Diameter Max (mm) Conductor Diameter Max (mm) Insulation Thickness Nom (mm) Conductor Resistance at 20°C (Ω/km) Short Circuit Current 1s (A) Cu Weight (kg/km) Cable Weight (kg/km) Packing
1 x 50/16RM28338.65.50.6414.7182806CUT
1 x 70/16RM303510.25.50.4436.58182903CUT
1 x 95/16RM313612.05.50.328.931821029CUT
1 x 120/16RM333813.55.50.25311.31821135CUT
1 x 150/16RM343915.05.50.20614.11821251CUT
1 x 150/25RM343915.05.50.20614.12831320CUT
1 x 185/16RM364116.85.50.16417.41821450CUT
1 x 185/25RM364116.85.50.16417.42831474CUT
1 x 240/16RM394419.25.50.12522.61821693CUT
1 x 240/25RM394419.25.50.12522.62831750CUT
1 x 300/25RM414621.65.50.128.22831911CUT
1 x 400/35RM444924.65.50.077837.63942330CUT
1 x 500/35RM475227.65.50.0605473942708CUT
1 x 630/35RM505529.35.50.046959.23943177CUT