logo

N2XS(FL)2Y / N2XS F 2Y NA2XSE(F)2Y Cable 1x185/25 1x240/25 1X300/25 12/20kV MV Cable Black/Red/Blue Sheath

Basic Properties
Place of Origin: Hebei, China
Brand Name: Minfeng
Certification: ISO,CE,IEC,TUV,KEMA
Model Number: N2XS(FL)2Y / N2XS F 2Y cable
Trading Properties
Minimum Order Quantity: 100m
Price: 0.1-5
Payment Terms: L/C,T/T
Supply Ability: 100KM/Week
Specifications
Origin: Hebei, China Insulation: XLPE
Product name: N2XS(FL)2Y / N2XS F 2Y Cable Cable Sample: Available
Cable Standard: IEC 60502-2, IEC 60228 Cable Jacket: PVC
Conductor Type: Copper Voltage rating: Up To 33kV
High Light:

XLPE insulated power cable 12/20kV

,

N2XS(FL)2Y MV cable 1x185/25

,

NA2XSE(F)2Y cable black sheath

Product Description
N2XS(FL)2Y / N2XS F 2Y NA2XSE(F)2Y Cable 1x185/25 1x240/25 1X300/25 12/20kV MV Cable Black/Red/Blue Sheath
High-performance medium voltage power cable designed for underground power transmission applications, available in black, red, or blue sheath colors.
N2XS(FL)2Y / N2XS F 2Y NA2XSE(F)2Y Medium Voltage Cable
Product Specifications
Type Insulated
Rated Voltage 12/20 kV
Conductor Material Copper or Aluminum
Insulation Material XLPE
Conductor Type Stranded
Application Underground
Core 1 Core
Size Range 35-630 mm²
Jacket PE/PVC
Brand Minfeng
Place of Origin Hebei, China
Construction Details
Conductor: Copper or aluminum, Class 2 stranded conductor
Conductor screen: Non-metallic, semi-conducting compound
Insulation: Cross-linked polyethylene (XLPE)
Insulation screen: Non-metallic, semi-conducting compound
Metallic screen: Copper wire with Copper tape
Swelling powder on tape, or + Aluminium tape tightly bonded to the PE Sheath
Outer sheath: PE
Compliance Standards: IEC 60228 Conductors, IEC 60502-2 Power cables with extruded insulation and their accessories for rated voltages from 1kV(Um=1.2kV) up to 35kV(Um=40.5kV)
Technical Parameters
Maximum Permissible D.C. Resistance of Conductor at 20°C (Class 2)
Nominal Section Area (mm²) Copper Conductor (Ω/km) Aluminum Conductor (Ω/km)
1.512.1-
2.57.4112.1
44.617.41
63.084.61
101.833.08
161.151.91
250.7271.20
350.5240.868
500.3870.641
700.2680.443
950.1930.320
1200.1530.253
1500.1240.206
1850.09910.164
2400.07540.125
3000.06010.100
4000.04700.0778
5000.03660.0605
6300.02830.0469
Maximum Permissible Short-Circuit Current for Conductor (1s Duration)
Nominal Section Area (mm²) Copper Conductor (kA) Aluminum Conductor (kA)
1.50.120.13
2.50.320.22
40.500.34
60.760.51
101.510.99
162.391.56
253.692.42
355.153.37
507.314.79
7010.26.68
9513.89.03
12017.411.4
15021.714.2
18526.717.5
24034.622.6
30043.128.2
40057.437.65
50071.747.0
63088.858.0