CABLE HFG DE U1000 RVFV/HFG Copper Conductor XLPE Insulated Galvanized Double Steel Tape Armored PVC Jacket 1000V

Basic Properties
Place of Origin: Hebei, China
Brand Name: Minfeng
Certification: ISO,CE,IEC,TUV,KEMA
Model Number: CABLE HFG DE
Trading Properties
Minimum Order Quantity: 100m
Price: 0.1-5
Payment Terms: L/C,T/T
Supply Ability: 100KM/Week
Specifications
Voltage Rating: 1kV Keywords: CABLE HFG DE
Temperature: +90°C Insulation: XLPE
Sample: Available Cable Jacket: PVC
Product Description

Key attributes


Rated Voltage
1000V
Size
1.5-300sqmm
Conductor Material
Copper
Insulation Material
XLPE
Working Temperature
70°C
Jacket
PVC
Type
Low Voltage
Place of Origin
China
Usage
power transmission
Core
single or multi CORES
Size
1.5-300sqmm
Standard
IEC 60502-1
Jacket
Flame retardant PVC
Package
Wooden drum
Delivery time
15days
Rated Temperature
+90°C
Product name
cable HFG CABLE
Armour type
double steel tape armored

CABLE HFG DE  U1000 RVFV/HFG Copper Conductor XLPE Insulated Galvanized TWO Steel Tape Insulated for Power Stations

Cable HFG DE Application

Steel tape cable is suitable for AC 50Hz power and distribution lines with rated voltage of 0.6/1kV, which can be used in fixed industrial power applications, underground tunnels, etc. Using steel wire armour offers great mechanical protection, making it rigid with a large radius.

Cable HFG DE

Standards:


IEC 60228 Conductors
IEC 60502-1 Power cables with extruded insulation and their accessories for rated voltages from 1kV(Um=1.2kV) up to 30kV(Um=36kV) - Part 1: Cables for rated voltages of 1 kV(Um=1.2kV) and 3 kV(Um=3.6kV)

CABLE HFG DE U1000 RVFV/HFG Copper Conductor XLPE Insulated Galvanized Double Steel Tape Armored PVC Jacket 1000V for Power


 CABLE HFG DE U1000 RVFV/HFG Copper Conductor XLPE Insulated Galvanized Double Steel Tape Armored PVC Jacket 1000V for PowerCABLE HFG DE U1000 RVFV/HFG Copper Conductor XLPE Insulated Galvanized Double Steel Tape Armored PVC Jacket 1000VCABLE HFG DE U1000 RVFV/HFG Copper Conductor XLPE Insulated Galvanized Double Steel Tape Armored PVC Jacket 1000V for PowerCABLE HFG DE U1000 RVFV/HFG Copper Conductor XLPE Insulated Galvanized Double Steel Tape Armored PVC Jacket 1000V for PowerCABLE HFG DE U1000 RVFV/HFG Copper Conductor XLPE Insulated Galvanized Double Steel Tape Armored PVC Jacket 1000V for PowerCABLE HFG DE U1000 RVFV/HFG Copper Conductor XLPE Insulated Galvanized Double Steel Tape Armored PVC Jacket 1000V for Power

CONSTRUCTION :

DTA Cable Construction

 CABLE HFG DE U1000 RVFV/HFG Copper Conductor XLPE Insulated Galvanized Double Steel Tape Armored PVC Jacket 1000V for Power
TECHNICAL DATA :

Voltage Rating Uo/U (Um) 0.6/1 (1.2)kV
Nominal Voltage DC (core-earth/core-core) :1.8/1.8kV
Test Voltage:4kV
Temperature Rating:
Flexed: 5°C to +90°C
Fixed: -35°C to +90°C
Maximum Short Circuit Temperature:
+250°C (max 5 seconds)
Minimum Bend Radius:
Single core: 15 x overall diameter
Multi core: 12 x overall diameter 

PARAMETER :
0.6/1kV-1 core copper conductor XLPE insulated steel tape armored PVC sheathed power cable
Nominal cross sectional area Insulation thickness Non-magnetic steel tape thickness  Sheath thickness Approximate outer diameter Approx.
weight
Max.D.C resistance of conductor(20℃) Current carrying capacity 
mm2 mm mm mm mm kg/km OHM/km In Air(A) In Ground(A)
1X10 0.7 0.2 1.8 11.8 244.0 1.83 75 47
1X16 0.7 0.2 1.8 12.9 318.0 1.15 97 62
1X25 0.9 0.2 1.8 14.6 430.0 0.727 125 78
1X35 0.9 0.2 1.8 15.2 533.0 0.524 155 94
1X50 1.0 0.2 1.8 16.7 668.0 0.387 190 110
1X70 1.1 0.2 1.8 18.5 893.0 0.268 245 135
1X95 1.1 0.2 1.8 20.1 1157.0 0.193 300 160
1X120 1.2 0.2 1.8 21.7 1410.0 0.153 350 185
1X150 1.4 0.2 1.8 23.7 1705.0 0.124 400 205
1X185 1.6 0.2 1.8 25.7 2082.0 0.0991 460 235
1X240 1.7 0.2 1.8 28.0 2652.0 0.0754 - -
1X300 1.8 0.2 1.9 31.0 3259.0 0.0601 - -
1X400 2.0 0.2 2.0 35.0 4135.0 0.047 - -









0.6/1kV-2 core copper conductor XLPE insulated steel tape armored PVC sheathed power cable
Nominal cross sectional area Insulation thickness Non-magnetic steel tape thickness  Sheath thickness Approximate outer diameter Approx.
weight
Max.D.C resistance of conductor(20℃) Current carrying capacity 
mm2 mm mm mm mm kg/km ohm/km In Air(A) In Ground(A)
2X2.5 0.7 0.2 1.8 13.4 230 7.41 - 45
2X4 0.7 0.2 1.8 14.3 277 4.61 - 59
2X6 0.7 0.2 1.8 15.3 336 3.08 - 74
2X10 0.7 0.2 1.8 17.8 452 1.83 64 100
2X16 0.7 0.2 1.8 20.0 609 1.15 83 135
2X25 0.9 0.2 1.8 23.3 845 0.727 110 165
2X35 0.9 0.2 1.8 24.6 1065 0.524 135 200
2X50 1.0 0.2 1.8 27.2 1297 0.387 165 240
2X70 1.1 0.2 1.9 31.4 1775 0.268 210 295
2X95 1.1 0.2 2.0 35.5 2340 0.193 260 355
2X120 1.2 0.5 2.2 40.2 3238 0.153 305 405
2X150 1.4 0.5 2.3 44.2 3971 0.124 345 455
2X185 1.6 0.5 2.5 48.9 4845 0.0991 396 515









0.6/1kV-3 core copper conductor XLPE insulated steel tape armored PVC sheathed power cable
Nominal cross sectional area Insulation thickness Non-magnetic steel tape thickness  Sheath thickness Approximate outer diameter Approx.
weight
Max.D.C resistance of conductor(20℃) Current carrying capacity 
mm2 mm mm mm mm kg/km ohm/km In Air(A) In Ground(A)
3X2.5 0.7 0.2 1.8 13.9 265 7.41 - 35
3X4 0.7 0.2 1.8 14.8 328 4.61 - 50
3X6 0.7 0.2 1.8 16.0 410 3.08 - 60
3X10 0.7 0.2 1.8 18.6 560 1.83 64 85
3X16 0.9 0.2 1.8 21.0 775 1.15 83 110
3X25 0.9 0.2 1.8 24.6 1098 0.727 110 140
3X35 0.9 0.2 1.8 26.0 1410 0.524 135 170
3X50 1.0 0.2 1.9 28.9 1780 0.387 165 200
3X70 1.1 0.2 2.0 33.9 2475 0.268 210 245
3X95 1.1 0.5 2.2 39.0 3260 0.193 260 300
3X120 1.2 0.5 2.3 42.7 4477 0.153 305 335
3X150 1.4 0.5 2.4 47.5 5440 0.124 345 380
3X185 1.6 0.5 2.6 52.1 6707 0.0991 395 430
3X240 1.7 0.5 2.8 58.3 8533 0.0754 465 500
3X300 1.8 0.5 2.9 63.6 10455 0.0601 535 565









0.6/1kV-4 core copper conductor XLPE insulated steel tape armored PVC sheathed power cable
Nominal cross sectional area Insulation thickness Non-magnetic steel tape thickness  Sheath thickness Approximate outer diameter Approx.
weight
Max.D.C resistance of conductor(20℃) Current carrying capacity 
mm2 mm mm mm mm kg/km ohm/km In Air(A) In Ground(A)
4X2.5 0.7 0.2 1.8 14.7 308 7.41 - 35
4X4 0.7 0.2 1.8 15.8 388 4.61 - 50
4X6 0.7 0.2 1.8 17.0 488 3.08 - 60
4X10 0.7 0.2 1.8 20.0 681 1.83 64 85
4X16 0.9 0.2 1.8 22.7 960 1.15 83 110
4X25 0.9 0.2 1.8 26.7 1375 0.727 110 140
4X35 0.9 0.2 1.8 28.3 1779 0.524 135 170
4X50 1.0 0.2 2.1 32.0 2296 0.387 165 200
4X70 1.1 0.5 2.1 38.5 3175 0.268 210 245
4X95 1.1 0.5 2.3 42.9 4665 0.193 260 300
4X120 1.2 0.5 2.4 47.4 5728 0.153 305 335
4X150 1.4 0.5 2.6 52.3 6999 0.124 345 380
4X185 1.6 0.5 2.7 57.5 8657 0.0991 395 430
4X240 1.7 0.5 3.0 64.3 11000 0.0754 465 500
4X300 1.8 0.5 3.1 70.3 13587 0.0601 535 565









0.6/1kV-5 core copper conductor XLPE insulated steel tape armored PVC sheathed power cable
Nominal cross sectional area Insulation thickness Non-magnetic steel tape thickness  Sheath thickness Approximate outer diameter Approx.
weight
Max.D.C resistance of conductor(20℃) Current carrying capacity 
mm2 mm mm mm mm kg/km ohm/km In Air(A) In Ground(A)
5X2.5 0.7 0.2 1.8 15.6 350 7.41 - 35
5X4 0.7 0.2 1.8 16.8 447 4.61 - 50
5X6 0.7 0.2 1.8 18.2 569 3.08 - 60
5X10 0.7 0.2 1.8 21.6 805 1.83 64 85
5X16 0.7 0.2 1.8 24.6 1150 1.15 83 110
5X25 0.9 0.2 1.8 29.0 1655 0.727 110 140
5X35 0.9 0.2 1.9 31.0 2166 0.524 135 170
5X50 1.0 0.2 2.1 35.7 2945 0.387 165 200
5X70 1.1 0.5 2.3 42.4 4453 0.268 210 245
5X95 1.1 0.5 2.4 47.2 5862 0.193 260 300
5X120 1.2 0.5 2.6 51.8 7176 0.153 305 335
5X150 1.4 0.5 2.7 57.6 8770 0.124 345 380
5X185 1.6 0.5 2.9 63.8 10827 0.0991 395 430
5X240 1.7 0.5 3.2 70.7 13770 0.0754 465 500
5X300 1.8 0.5 3.4 78.0 16960 0.0601 535 565









0.6/1kV-3+1 core copper conductor XLPE insulated steel tape armored PVC sheathed power cable
Nominal cross sectional area Insulation thickness Non-magnetic steel tape thickness  Sheath thickness Approximate outer diameter Approx.
weight
Max.D.C resistance of conductor(20℃) Current carrying capacity 
mm2 mm mm mm mm kg/km ohm/km In Air(A) In Ground(A)
3X4+1X2.5 0.7/0.7 0.2 1.8 15.5 368 4.61/7.41 - 50
3X6+1X4 0.7/0.7 0.2 1.8 16.8 465 3.08/4.61 - 60
3X10+1X6 0.7/0.7 0.2 1.8 19.3 633 1.83/3.08 64 85
3X16+1X10 0.7/0.7 0.2 1.8 22.1 890 1.15/1.83 83 110
3X25+1X16 0.9/0.7 0.2 1.8 25.1 1272 0.727/1.15 110 140
3X35+1X16 0.9/0.7 0.2 1.8 26.8 1583 0.524/1.15 135 170
3X50+1X25 1/0.9 0.2 1.9 30.2 2030 0.387/0.727 165 200
3X70+1X35 1.1/0.9 0.2 2.0 35.1 2810 0.268/0.524 210 245
3X95+1X50 1.1/1.0 0.5 2.2 40.4 4135 0.193/0.387 260 300
3X120+1X70 1.2/1.1 0.5 2.3 45 5135 0.153/0.268 305 335
3X150+1X70 1.4/1.1 0.5 2.5 49.1 6120 0.124/0.268 345 380
3X185+1X95 1.6/1.1 0.5 2.8 54.3 7616 0.0991/0.193 395 430
3X240+1X120 1.7/1.2 0.5 2.8 59.1 9679 0.0754/0.153 465 500
3X300+1X150 1.8/1.4 0.5 3.0 66 11889 0.0601/0.124 535 565









0.6/1kV-4+1 core copper conductor XLPE insulated steel tape armored PVC sheathed power cable
Nominal cross sectional area Insulation thickness Non-magnetic steel tape thickness  Sheath thickness Approximate outer diameter Approx.
weight
Max.D.C resistance of conductor(20℃) Current carrying capacity 
mm2 mm mm mm mm kg/km ohm/km In Air(A) In Ground(A)
4X4+1X2.5 0.7/0.7 0.2 1.8 16.3 434 4.61/7.41 - 50
4X6+1X4 0.7/0.7 0.2 1.8 17.7 549 3.08/4.61 - 60
4X10+1X6 0.7/0.7 0.2 1.8 20.3 759 1.83/3.08 64 85
4X16+1X10 0.7/0.7 0.2 1.8 24 1079 1.15/1.83 83 110
4X25+1X16 0.9/0.7 0.2 1.8 28.1 1557 0.727/1.15 110 140
4X35+1X16 0.9/0.7 0.2 1.9 29.6 1962 0.524/1.15 135 170
4X50+1X25 1/0.9 0.2 2.0 34 2601 0.387/0.727 165 200
4X70+1X35 1.1/0.9 0.5 2.2 40.3 3916 0.268/0.524 210 245
4X95+1X50 1.1/1.0 0.5 2.3 44.8 5260 0.193/0.387 260 300
4X120+1X70 1.2/1.1 0.5 2.6 50.2 6545 0.153/0.268 305 335
4X150+1X70 1.4/1.1 0.5 2.8 54.6 7780 0.124/0.268 345 380
4X185+1X95 1.6/1.1 0.5 2.9 60.5 9688 0.0991/0.193 395 430
4X240+1X120 1.7/1.2 0.5 3.0 67.1 12253 0.0754/0.153 465 500
4X300+1X150 1.8/1.4 0.5 3.2 73.7 15078 0.0601/0.124 535 565









0.6/1kV-3+2 core copper conductor XLPE insulated steel tape armored PVC sheathed power cable
Nominal cross sectional area Insulation thickness Non-magnetic steel tape thickness  Sheath thickness Approximate outer diameter Approx.
weight
Max.D.C resistance of conductor(20℃) Current carrying capacity 
mm2 mm mm mm mm kg/km ohm/km In Air(A) In Ground(A)
3X4+2X2.5 0.7/0.7 0.2 1.8 16.6 412 4.61/7.41 - 50
3X6+2X4 0.7/0.7 0.2 1.8 18 525 3.08/4.61 - 60
3X10+2X6 0.7/0.7 0.2 1.8 20.9 714 1.83/3.08 64 85
3X16+2X10 0.7/0.7 0.2 1.8 24 1016 1.15/1.83 83 110
3X25+2X16 0.9/0.7 0.2 1.8 28.1 1465 0.727/1.15 110 140
3X35+2X16 0.9/0.7 0.2 1.9 29.6 1769 0.524/1.15 135 170
3X50+2X25 1/0.9 0.2 2.0 34 2316 0.387/0.727 165 200
3X70+2X35 1.1/0.9 0.5 2.2 40.3 3230 0.268/0.524 210 245
3X95+2X50 1.1/1.0 0.5 2.3 44.8 4766 0.193/0.387 260 300
3X120+2X70 1.2/1.1 0.5 2.5 50.2 6080 0.153/0.268 305 335
3X150+2X70 1.4/1.1 0.5 2.6 54.6 7005 0.124/0.268 345 380
3X185+2X95 1.6/1.1 0.5 2.8 60.5 8767 0.0991/0.193 395 430
3X240+2X120 1.7/1.2 0.5 3.0 67.1 11105 0.0754/0.153 465 500
3X300+2X150 1.8/1.4 0.5 3.2 73.7 13645 0.0601/0.124 535 565