6.6kV 95mm 4 Core Armoured Cable XLPE Insulated For Industrial Power Distribution
Basic Properties
Place of Origin:
Hebei, China
Brand Name:
Minfeng
Certification:
ISO,CE,IEC,TUV,KEMA
Model Number:
armored cable
Trading Properties
Minimum Order Quantity:
100
Price:
0.1-5
Payment Terms:
L/C,T/T
Supply Ability:
100KM/Week
Specifications
| Productname: | Armoured Cable | Standard: | AISI, ASTM, BS, DIN, GB, JIS |
| Cabletype: | Armoured | Sheathmaterial: | PVC Or PE |
| Cablesize: | Varies From 1.5mm² To 1000mm² | Conductormaterial: | Copper Or Aluminum |
| Flameretardant: | Yes/No | Insulationmaterial: | PVC, XLPE, Or Rubber |
| High Light: | 95mm 4 Core Armoured Cable,6.6kV Armoured Cable |
||
Product Description
6.6kV 95mm 50mm 4-5 Core XLPE Insulated Armoured Power Cable
High-quality medium voltage power cables manufactured to international standards for reliable power distribution and transmission applications.
Product Specifications
| Conductor Material | Aluminum |
|---|---|
| Insulation Material | PVC XLPE |
| Jacket | PVC |
| Application | Construction |
| Type | Medium Voltage |
| Place of Origin | Hebei, China |
| Model Number | YJLV |
| Brand Name | Minfeng |
| Product Name | 50mm 4 Core Armoured Cable |
| Conductor | Stranded Aluminum Conductor |
| Certificate | ISO9001/ISO14001/OHSAS18001/CCC |
| Standard | BS IEC ASTM DIN |
| Core | Multicore |
| Insulation | XLPE PE PVC |
| Rated Voltage | 1-35KV |
| Armour | Steel Tape |
Product Range & Technical Details
| Product Name | Copper core or aluminum core XLPE insulated PVC sheathed power cable Copper core or aluminum core XLPE insulated steel tape armoured PVC sheathed power cable Copper core or aluminum core XLPE insulated steel wire armoured PVC sheathed power cable |
|---|---|
| Rated Voltage | 0.6/1kV, 1.8/3kV, 3.6/6kV, 6/10kV, 8.7/15kV, 12/20kV, 21/35kV, 26/35kV |
| Standard | B/T12706-2008, GB/T12703-200, IEC60502-1-1997 |
| Model | YJV, YJLV, YJV22, YJLV22, YJV32, YJLV32, YJV42, YJLV42 |
| Armoured | Steel tape armored, steel wire armored, Double of galvanized steel tape or galvanized steel wire for three core power cable, Double of aluminium tape or aluminium wire for single power cable |
| Number of Cores | Single core, 2 cores, 3 cores, 4 cores, 5 cores, 3+1 cores, 3+2 cores, 4+1 cores, etc. |
| Common Size | 1mm², 1.5mm², 2.5mm², 4mm², 6mm², 10mm², 16mm², 25mm², 35mm², 50mm², 70mm², 95mm², 120mm², 150mm², 185mm², 240mm², 300mm², 400mm², 500mm², 630mm², 800mm², 1000mm², etc. |
| Types | Ordinary type, flame-retardant type, fire-resistant type, low-smoke halogen-free type |
| Application | Power distribution engineering, power transmission engineering, electromechanical and hydropower installation engineering, power transmission, power supply installation system, control system, etc. |
Product Description
XLPE Insulated Power Cables are designed for transmitting and distributing electrical energy. These cables are extensively used in urban underground power grids, power station outgoing lines, industrial and mining enterprise internal power supply, and underwater transmission lines across rivers. YJV cables serve as backbone cables in power transmission systems, typically installed in urban underground passages or buried underground.
Installation Precautions
- The minimum bending radius when laying the cable should not be less than 10 times the outer diameter of the cable
- YJV/YJLV cables are suitable for indoor installation, in channels and pipes, and can be buried in loose soil where they cannot bear external forces
- YJV22/YJLV22 cables are designed for underground laying and can withstand external mechanical forces, but cannot承受 large tensile forces
- Special tools should be used for cable laying, such as pay-off racks, guide rollers, etc., to prevent mechanical damage during installation and keep away from heat sources
- When laying cables through pipes, the inner diameter of the pipe should not be less than 1.5 times the outer diameter of the cable. Do not挤压 the cable when passing through the pipe. The total area of the cable should not exceed 40% of the total area of the pipe
Product Images
Overall Rating
5 star
100%
4 star
0
3 star
0
2 star
0
1 star
0
All Reviews
-
GThe LSZH (Low Smoke Zero Halogen) properties of these cables are exactly as advertised. They performed exceptionally well during our fire safety compliance audit.
-
IOur field technicians have specifically requested this brand because the cable is easy to strip and pull through conduits, saving us significant man-hours on-site.
-
FFully impressed with the rigorous adherence to CE standards. It’s rare to find a manufacturer so meticulous about certification documentation.