300V/500V Rated Voltage Fireproof Instrument Cable with LSZH/PVC Jacket and Flexible Copper Conductor
| Marking: | Laser Printing | Corporation: | Minfeng Cable Group |
| Cable Jacket: | LSZH/PVC | Insulation: | XLPE /PVC |
| Rated Voltage: | 300V/500V | Transport Package: | Wooden Steel Drum |
| Temperature Range: | -40°C To +80°C |
Mica tape fireproof instrument cable designed for electrical instrument circuits and communication services in process plants where circuit integrity is required during fire situations.
These cables are designed to connect electrical instrument circuits and provide communication services in and around process plants (e.g., petrochemical industry). Not suitable for direct burial applications. Used in areas where circuit integrity is required in the event of a fire situation. For installations where fire, smoke emissions, and toxic fumes create a potential risk to life and equipment.
- Voltage Rating: 300V
- Operating Temperature: Fixed: -40°C to +80°C, Flexed: 0°C to +50°C
- Minimum Bending Radius: 10 x overall diameter
Construction: Conductor 0.5mm² - 0.75mm²: Class 5 flexible Copper; 1mm² and above: Class 2 stranded Copper. Insulation: XLPE (Cross-Linked Polyethylene). Collective Screen: Al/PET (Aluminium/Polyester Tape). Drain Wire: Tinned Copper. Inner Sheath: LSZH (Low Smoke Zero Halogen). Armour: SWA (Galvanised steel wires). Outer Sheath: LSZH (Low Smoke Zero Halogen) - UV Resistant.
- Voltage Rating: 300V
- Operating Temperature: Fixed: -40°C to +80°C, Flexed: 0°C to +50°C
- Minimum Bending Radius: 6 x overall diameter
Construction: Conductor 0.5mm² - 0.75mm²: Class 5 flexible copper conductor; 1mm² and above: Class 2 stranded copper conductor. Insulation: XLPE (Cross-Linked Polyethylene). Collective Screen: Al/PET (Aluminium/Polyester Tape). Drain Wire: Tinned copper. Sheath: PVC (Polyvinyl Chloride) - UV Resistant.
- Voltage Rating: 300V
- Operating Temperature: Fixed: -40°C to +80°C, Flexed: 0°C to +50°C
- Minimum Bending Radius: 10 x overall diameter
Construction: Conductor 0.5mm² - 0.75mm²: Class 5 flexible copper conductor; 1mm² and above: Class 2 stranded copper conductor. Insulation: PE (Polyethylene). Collective Screen: Al/PET (Aluminium/Polyester Tape). Drain Wire: Tinned Copper. Inner Sheath: PVC (Polyvinyl Chloride). Armour: SWA (Galvanised steel wires). Outer Sheath: PVC (Polyvinyl Chloride) - UV Resistant.
- Voltage Rating (Uo/U): 300/500V
- Operating Temperature: Fixed: -30°C to +90°C
- Minimum Bending Radius: 7.5 x overall diameter
Construction: Conductor: Class 2 stranded copper conductor. Insulation: Mica Tape / XLPE (Cross-Linked Polyethylene). Individual And Collective Screen Or Collective Screen: PET (Polyester Tape), AL/PET (Aluminium/Polyester Tape) with tinned drain wire. Multi-Core, Multi-Pair, PiMF and TiMF Type. Sheath: LSZH (Low Smoke Zero Halogen).
| No. of Cores | Nominal Cross Sectional Area (mm²) | Nominal Overall Diameter (mm) | Nominal Weight (kg/km) |
|---|---|---|---|
| 7 | 1.5 | 9.7 | 179 |
| 7 | 2.5 | 11.7 | 265 |
| 10 | 0.5 | 9.4 | 115 |
| 10 | 0.75 | 10.1 | 152 |
| 10 | 1 | 11.1 | 192 |
| 10 | 1.5 | 12.4 | 253 |
| 10 | 2.5 | 15 | 374 |
| 12 | 0.5 | 9.6 | 135 |
| 12 | 0.75 | 10.4 | 173 |
| 12 | 1 | 11.5 | 220 |
| 12 | 1.5 | 12.8 | 292 |
| 12 | 2.5 | 15.4 | 433 |
| 19 | 0.5 | 11.5 | 201 |
| 19 | 0.75 | 12.3 | 260 |
| 19 | 1 | 13.4 | 322 |
| 19 | 1.5 | 15.1 | 445 |
| 19 | 2.5 | 18.3 | 665 |
-