0.6/1 KV 4 Core Copper Conductor PVC Insulated Cables Electric Power Transmission Cables
| Conductor Type: | Copper Conductor | Free Sample: | Avaliable |
| Sheath Color: | Normally Black Or Customization | Number Of Cores: | 1-63 |
| Performance: | High Tension | Flame Retardant: | Yes/No (depending On Type) |
| Insulation Material: | PVC (Polyvinyl Chloride) | Sheath Material: | PVC |
| High Light: | 4 Core PVC Insulated Cables,1 KV PVC Insulated Cables,Electric Power Transmission Cables |
||
High-quality 0.6/1 kV power cable designed for reliable power transmission and distribution applications, manufactured to IEC 60502 standards.
Type: Insulated
Conductor Material: Copper or Aluminum
Insulation Material: PVC
Conductor Type: Plain annealed copper conductor class 2
Application: Power transmission & distribution
Standard: IEC 60502
Voltage: 0.6/1 kV
Cross Section: 1.5mm²-800mm²
Core Configuration: 1, 2, 3, 4, 5, 3+1, 3+2, 4+1
Conductor: Plain annealed stranded circular copper conductor, as per Class 2 of IEC 60228. Stranded circular aluminium conductor, as per Class 2 of IEC 60228.
Insulation: An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70°C at normal operation to IEC 60502-1.
Outer Sheath: An extruded layer of Polyvinyl chloride (PVC) sheathing compound type ST1 to IEC 60502-1.
For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants and switchgears if mechanical protection is not required, or in applications where the cable is not exposed to mechanical damage.
- Nominal voltage Uo/U = 0.6/1 kV
- Power frequency test voltage 3.5 kV for 5 minutes
- Max. admissible temperature of conductor at normal operation 70°C
- Max. admissible temperature of conductor at short circuit for 5 seconds: 160°C for sizes ≤ 300 mm², 140°C for sizes > 300 mm²
| Type | No. of cores | Nom. Cross-section of conductor (mm²) |
|---|---|---|
| Copper conductor | Aluminum conductor | |
| YJV YJY | - | 1 |
| - | YJLV YJLY | 2.5-800 |
| YJV22 YJV23 | YJLV22 YJLY23 | 10-800 |
| YJV YJY | - | 2 |
| - | YJLV YJLY | 2.5-300 |
| YJV22 YJV23 | YJLV22 YJLY23 | 4.0-300 |
| YJV32 YJV33 | YJLV32 YJLY33 | 10-300 |
| YJV YJY | - | 3 |
| - | YJLV YJLY | 2.5-400 |
| YJV22 YJV23 | YJLV22 YJLY23 | 4.0-400 |
| YJV32 YJV33 | YJLV32 YJLY33 | 10-400 |
| YJV YJY | - | 4 |
| - | YJLV YJLY | 2.5-400 |
| YJV22 YJV23 | YJLV22 YJLY23 | 4.0-400 |
| YJV32 YJV33 | YJLV32 YJLY33 | 10-400 |
The armoured single core cables are used for D.C. system only. As for A.C. system, non-magnetic armour material should be used, or a magnetic isolation should be applied.
-
MIn an industry plagued by shortages, this manufacturer’s ability to maintain a steady lead time is a massive asset to our supply chain.
-
SWe’ve been ordering from this factory for three years. The consistency between batches is incredible; the quality of the first shipment matches the hundredth
-
EWe appreciate the precision in the meter marking. Every spool delivered was exactly to specification, which significantly reduced our waste during installation.