Underground Steel Wire Armoured Cable With XLPE Insulation Aluminum Conductor
| Productname: | Armoured Cable | Standard: | AISI, ASTM, BS, DIN, GB, JIS |
| Cabletype: | Armoured | Sheathmaterial: | PVC Or PE |
| Cablesize: | Varies From 1.5mm² To 1000mm² | Conductormaterial: | Copper Or Aluminum |
| Flameretardant: | Yes/No | Insulationmaterial: | PVC, XLPE, Or Rubber |
| High Light: | Underground Armoured Cable,Steel Wire Armoured Cable |
||
- Conductor: Solid or stranded copper/aluminum
- Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)
- Filler: Polypropylene filament with lapped binding tape
- Binder: Binding tape
- Inner sheath: Polyvinyl chloride (PVC)
- Armouring: Single Core: AWA (Aluminium Wire Armour)
Multi Core: SWA (Steel Wire Armour) STA (Steel Tape Armour)
Copper aluminum conductor, XLPE insulated, tape armoured and PVC sheathed. Suitable for installations:
- Indoors: Mostly in power supply stations
- Outdoors: In cable ducts, underground, and on cable trays for industries, switch-boards and power stations
Due to excellent laying and mechanical characteristics, this cable is ideal when mechanical protection is required or in applications where mechanical damages are expected to occur.
- High Temperature Resistance: XLPE insulation uses chemical or physical methods to create a three-dimensional network structure, allowing long-term operation at 90°C with lifespan up to 40 years
- Excellent Insulation Performance: Retains polyethylene insulation properties with improved insulation resistance
- High Mechanical Properties: Enhanced hardness, stiffness, wear resistance and impact resistance
- Chemical Resistance: Strong resistance to acids, alkalis and oils
- Environmental Safety: Combustion products are water and carbon dioxide, meeting fire safety requirements
- Temperature Ratings: Maximum conductor temperature 90°C during normal operation, 250°C during short circuit (max 5 seconds duration)
Insulated PVC/XLPE sheathed power cable used for power transmission and distribution systems with rated voltages of 0.6/1, 1.8/3, 3.6/6, 6/10, 8.7/10, 8.7/15, 12/20, 21/35, 26/35KV.
- YJV, YJLV: XLPE insulated, PVC sheathed - suitable for indoors, tunnels, pipes, and buried in soil (not subject to mechanical force)
- YJV22, YJLV22: XLPE insulated, steel tape armored PVC sheathed - suitable for indoor, tunnel, pipe penetration, and buried in soil
- YJV32, 42, YJLV32, 42: XLPE insulated, steel wire armored PVC sheathed - suitable for shafts, water, places with drop, and can withstand external forces
- Normal Operation Temperature: 70°C for PVC insulation, 90°C for XLPE insulation
- Short Circuit Temperature: PVC insulation: 160°C (≤300mm²), 140°C (>300mm²); XLPE insulation: 250°C
- Installation Temperature: Ambient temperature not less than 0°C
- Minimum Bending Radius: Single core: unarmored 20D, armored 15D; Multi-core: unarmored 15D, armored 12D (D = cable outer diameter)
- Cable Breaking Force: Aluminum core: 40*S (N); Copper core: 70*S (N)
-
AInternational shipping can be rough, but the reinforced wooden drumming used by this supplier ensured the cable arrived in pristine condition without any kinks.
-
SWe’ve been ordering from this factory for three years. The consistency between batches is incredible; the quality of the first shipment matches the hundredth
-
FFully impressed with the rigorous adherence to CE standards. It’s rare to find a manufacturer so meticulous about certification documentation.