70mm2 95mm2 Aluminum Overhead Aerial Bundle Cable ABC Power Transmission Cable
| Range Of Application: | Overhead | Wire Core Material: | Aluminium |
| Sample: | Freely Supplied | Product Time: | 10days |
| Model No: | ABC | Quality: | Top |
| High Light: | 95mm2 Aerial Bundle Cable,Overhead Aerial Bundle Cable,ABC Power Transmission Cable |
||
Overhead insulated cables are composed of copper or aluminum conductors, inner shielding layer, weather-resistant insulating material and outer shielding layer. Aerial insulated cables have not only the power transmission characteristics of power cables, but also the strong mechanical characteristics of overhead cables. Compared with bare wires, overhead insulated cables have many advantages such as small laying span, high reliability, and good anti-aging performance. They are the types of cables that are actively selected for urban power projects.
| Product Name | Aerial Cable |
| Model | JKTRYJ; JK(L)YJ; JK(L)Y; JKLGYJ; JKLGY; JKLYJ/Q; JKLY/Q; JKLGYJ/Q; JKLGY/Q; JKLGYJ / JKV / JKLV / JKLHV / JKY / JKLY / JKLHY / JKYJ / JKIYJ / JKLHYJ / JKTRYJ |
| Section (aluminum/steel) mm² | 10-240mm² 10/2-500/65 (JKLGYJ-10) 25-240 25-120 (JKYJ JKTRYJ) |
| Insulation | Cross-linked polyethylene (XLPE) insulated, covered for weather proofing with polyethylene (PVC), high density polyethylene (HDPE) |
| Conductor | HD Copper Wire, 1350-H19 Aluminum Wire, or ACSR conductors, concentrically stranded |
| Standard | GB/T12527-2008 GB/T1179-2008 GB/T14049-2008 / IEC 60502 / IEC 60227 |
| Type | Name | Nominal Cross-Section Area mm² | Application |
|---|---|---|---|
| JKTRYJ | Soft copper conductor XLPE insulation aerial cable | 10~120 | The transformer leads to connect the line |
| JK(L)YJ | Cu (Al) conductor XLPE insulation Aerial cable | 16~240 | In fixedly laying the cable, The user must keep certain distance between cable and trees. During power transmission, allow the cable with the multifarious contact in tree |
| JK(L)Y | Cu (Al) conductor XLPE insulation Aerial cable | 16~240 | |
| JKLGYJ | Steel-Al conductor XLPE insulation Aerial cable | 25/4~300/40 | |
| JKLGY | Steel-Al conductor HDPE insulation Aerial cable | 25/4~300/40 | |
| JKLYJ/Q | Al conductor light XLPE insulation Aerial cable | 16~240 | In fixedly laying the cable, The user must keep certain distance between cable and trees. During power transmission, the cable can be allowed in contact with trees just for a short time. |
| JKLY/Q | Al conductor light HDPE insulation Aerial cable | 16~240 | |
| JKLGYJ/Q | Steel-Al conductor light XLPE insulation Aerial cable | 16~240 | |
| JKLGY/Q | Steel-Al conductor light HDPE insulation Aerial cable | 16~240 |
| NCS-Area mm² | Conductor DC resistance Ω/km | Insulate resistance MΩ.km | Conductor Min Splitting Source | ||||
|---|---|---|---|---|---|---|---|
| Hard Cu | Cu | Al | 70°C | 90°C | Hard Cu | Al | |
| 10 | 1.906 | 1.83 | 3.08 | 0.0067 | 0.67 | 3471 | 1650 |
| 16 | 1.198 | 1.15 | 1.91 | 0.0065 | 0.65 | 5486 | 2517 |
| 25 | 0.749 | 0.727 | 1.2 | 0.0054 | 0.54 | 8465 | 3762 |
| 35 | 0.54 | 0.524 | 0.868 | 0.0054 | 0.54 | 11731 | 5177 |
| 50 | 0.399 | 0.387 | 0.641 | 0.0046 | 0.46 | 16502 | 7011 |
| 70 | 0.276 | 0.268 | 0.443 | 0.004 | 0.4 | 23461 | 10354 |
| 95 | 0.199 | 0.193 | 0.32 | 0.0039 | 0.39 | 31759 | 13727 |
| 120 | 0.158 | 0.153 | 0.253 | 0.0035 | 0.35 | 39911 | 17339 |
| 150 | 0.128 | / | 0.206 | 0.0035 | 0.35 | 49505 | 21033 |
| 185 | 0.1021 | / | 0.164 | 0.0035 | 0.35 | 61846 | 26732 |
| 240 | 0.0777 | / | 0.125 | 0.0034 | 0.34 | 79823 | 34679 |
| 300 | 0.0619 | / | 0.1 | / | / | 99788 | 43349 |
Overhead insulated cables, overhead wires equipped with an insulating layer and protective sheath, are a new power transmission method between overhead wires and underground cables.
Overhead cables are single-core, and can be divided into hard aluminum wire structure, hard drawn copper wire structure, aluminum alloy wire structure, steel core or aluminum alloy core support structure and self-supporting three-core pattern structure (wire core can be hard aluminum or hard copper wire) and so on.
It has the main characteristics of high power supply reliability, good power supply safety, convenient installation and maintenance, and reasonable economy.
- ASTM B-230, B-231, B-232 and B-399
- ICEA S-61-402 and S-66-524
- ASTM B-230, B-231, B-232 and B-399
- ICEA S-76-474
- ASTM B-230, B-231, B-232 and B-339
- ICEA S-76-474
Quadruplex service drop cable meets or exceeds the following ASTM specifications: B-230 Aluminum Wire, 1350-H19 for electrical Purposes. B-231 Aluminum conductors, Concentric-Lay-Stranded. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR). B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum. Service Drop cable meets or exceeds all applicable requirements of ICEA S-79-474.
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volt or lower at a conductor temperature of 75℃ maximum.
| Nominal cross section | Neutral core | Phase core | Weight (kg/km) | Allowable ampacity (A) | |||||
|---|---|---|---|---|---|---|---|---|---|
| AAC | LBS | AAC | Insulation thickness(mm) | XLPE | PE | ||||
| NO | diameter (mm) | NO | diameter(mm) | ||||||
| 1*6AWG+1*6AWG | 7 | 1.56 | 563 | 1 | 4.11 | 1.14 | 92 | 85 | 70 |
| 1*6AWG+1*6AWG | 7 | 1.56 | 563 | 7 | 1.56 | 1.14 | 94 | 85 | 70 |
| 1*4AWG+1*4AWG | 7 | 1.96 | 881 | 1 | 5.19 | 1.14 | 139 | 115 | 90 |
| 1*4AWG+1*4AWG | 7 | 1.96 | 881 | 7 | 1.96 | 1.14 | 141 | 115 | 90 |
| 1*2AWG+1*2AWG | 7 | 2.47 | 1350 | 7 | 2.47 | 1.14 | 216 | 150 | 120 |
| 1*1/0AWG+1*1/0AWG | 7 | 3.12 | 1990 | 19 | 1.89 | 1.52 | 347 | 205 | 160 |
Concentric strand or compressed 1350-H19 conductor polyethylene or crosslinked polyethylene insulation, concentric strand AAC, ACSR or 6210 alloy neutral messenger.
To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volt or less (phase to phase) at a conductor temperature of 75℃ maximum for polyethylene insulation or 90℃ maximum for crosslinked insulation.
| AWG or kcmil | Bare Neutral Messenger | Phase Conductor | Weight kg/km | Allowable Ampacities(A) | |||||
|---|---|---|---|---|---|---|---|---|---|
| AAC | Rated Strength lbs. | AAC | Insul. Thick. mm | XLPE | PE | ||||
| NO. | Dia.mm | NO. | Dia.mm | ||||||
| 2*6AWG+1*6AWG | 7 | 1.56 | 563 | 1 | 4.11 | 1.14 | 146 | 85 | 70 |
| 2*6AWG+1*6AWG | 7 | 1.56 | 563 | 7 | 1.56 | 1.14 | 150 | 85 | 70 |
| 2*4AWG+1*4AWG | 7 | 1.96 | 881 | 1 | 5.19 | 1.14 | 219 | 115 | 90 |
| 2*4AWG+1*4AWG | 7 | 1.96 | 881 | 7 | 1.96 | 1.14 | 224 | 115 | 90 |
| 2*2AWG+1*2AWG | 7 | 2.47 | 1350 | 7 | 2.47 | 1.14 | 338 | 150 | 120 |
| 2*1/0AWG+1*1/0AWG | 7 | 3.12 | 1990 | 7 | 3.12 | 1.52 | 544 | 205 | 160 |
| 2*1/0AWG+1*1/0AWG | 7 | 3.12 | 1990 | 19 | 1.89 | 1.52 | 545 | 205 | 160 |
| 2*2/0AWG+l*2/0AWG | 7 | 3.5 | 2510 | 7 | 3.5 | 1.52 | 671 | 235 | 185 |
| 2*3/0AWG+l*3/0AWG | 19 | 2.39 | 3310 | 19 | 2.39 | 1.52 | 830 | 275 | 215 |
| 2*4/0AWG+l*4/0AWG | 19 | 3.25 | 4020 | 19 | 3.25 | 1.52 | 1476 | 315 | 245 |
| 2*336.4+1*336.4 | 19 | 3.38 | 6146 | 19 | 3.38 | 2.03 | 1649 | 420 | 325 |
Conductors are concentrically stranded, compressed 1350-H19 aluminum, insulated with either polyethylene or XLPE crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR. One conductor is manufactured with an extruded ridge for phase identification.
Used to supply 3 phase power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75℃ for polyethylene insulated conductors or 90℃ for crosslinked polyethylene (XLPE) insulated conductors.
| AWG or kcmil | Bare Neutral Messenger | Phase Conductor | Weight kg/km | Allowable Ampacities(A) | |||||
|---|---|---|---|---|---|---|---|---|---|
| ACSR | Rated Strength lbs. | AAC | Insul. Thick. mm | XLPE | PE | ||||
| No. | Dia. mm | No. | Dia. mm | ||||||
| 3*6AWG+1*6AWG | 1,6 | 1.68 | 1190 | 1 | 4.11 | 1.14 | 221 | 75 | 60 |
| 3*6AWG+1*6AWG | 1,6 | 1.68 | 1190 | 7 | 1.56 | 1.14 | 227 | 75 | 60 |
| 3*4AWG+1*4AWG | 1,6 | 2.12 | 1860 | 1 | 5.19 | 1.14 | 331 | 100 | 80 |
| 3*4AWG+1*4AWG | 1,6 | 2.12 | 1860 | 7 | 1.96 | 1.14 | 338 | 100 | 80 |
| 3*2AWG+1*2AWG | 1,6 | 2.67 | 2850 | 7 | 2.47 | 1.14 | 511 | 135 | 105 |
| 3*1/0AWG+1*1/0AWG | 1,6 | 3.37 | 4380 | 19 | 1.89 | 1.52 | 824 | 180 | 140 |
| 3*2/0AWG+l*2/0AWG | 1,6 | 3.78 | 5310 | 19 | 2.13 | 1.52 | 1015 | 205 | 160 |
| 3*3/0AWG+l*3/0AWG | 1,6 | 4.25 | 6620 | 19 | 2.39 | 1.52 | 1254 | 235 | 185 |
| 3*4/0AWG+l*4/0AWG | 1,6 | 4.77 | 8350 | 19 | 2.68 | 1.52 | 1554 | 275 | 210 |
| 3*336.4+1*336.4 | 1,18 | 3.47 | 8680 | 19 | 3.38 | 2.03 | 2321 | 370 | 280 |
| 3*336.4+l*4/0AWG | 1,6 | 4.77 | 8350 | 19 | 3.38 | 2.03 | 2221 | 370 | 280 |
-