YnHKGSLY Signal Mining Cable with Tin-plated Copper Wire Screen Non-flammable PVC Sheath 150/250V 300/500V 0.6/1KV
الخصائص الأساسية
مكان المنشأ:
خبي، الصين
الاسم التجاري:
Minfeng
الشهادة:
ISO,CE,IEC,TUV,KEMA
رقم الموديل:
YnHKGSLY
تداول العقارات
الحد الأدنى لكمية الطلب:
100
سعر:
0.1-5
شروط الدفع:
الاعتماد المستندي، تي/تي
القدرة على العرض:
100 كم/أسبوع
تحديد
| Conductor material: | كوبر، فئة 5 متعددة الذين تقطعت بهم السبل. بن-إن 60228 | Keywords: | كابل التعدين |
| Sheath Material: | PVC خاص غير قابل للاشتعال | Hs Code: | 8544492100 |
| Voltagerating: | 150/250 فولت، 300/500 فولت، 0.6/1 كيلو فولت | Temperature: | -40 درجة مئوية إلى 70 درجة مئوية |
وصف المنتج
150/250V 300/500V 0.6/1KV PVC YnHKGSLY Signal Tin-plated Copper Wire Screen Mining Cable
Mining signal cable with copper, multistranded, PVC insulated conductors, individual conductor screening, PVC sheath with increased flame propagation resistance.
Product Specifications
| Rated Voltage | 150/250V 300/500V 0.6/1 kV |
|---|---|
| Size | 9.5-38.2mm |
| Conductor Material | Copper |
| Insulation Material | Special PVC |
| Working Temperature | -40°C to 70°C |
| Jacket | PVC |
| Application | Industrial |
| Type | Low Voltage |
| Model Number | YnHKGSLY |
| Standard | PN-EN 60228 |
Technical Data
- Operating temperature: -40°C to 70°C
- Minimum installation temperature: -5°C
- Operating voltage: 150/250V, 300/500V, 0.6/1 kV
- Test voltage: 1.5 kV for 150/250V, 2.0 kV for 300/500V, 3.5 kV for 0.6/1 kV
- Minimum bending radius: 10 x Ø
Cable Construction
- Conductors: Copper, multi-stranded class 5 according to PN-EN 60228
- Insulation: Special PVC
- Conductor marking: Natural or black with digit print; yellow-green conductor in the outer layer
- Conductor screen: Tin-plated copper wire braid
- Outer sheath: Special, non-flammable PVC preventing flame propagation (tested according to PN-EN 60332-1 and PN-EN 60332-3-24, IEC 60332-3), oxygen index > 29
- Sheath color: Grey for 150/250V, 300/500V; Yellow for 0.6/1 kV
Application
Cables intended for supplying and controlling power control, safety and control systems in strip, open-pit and underground mines, out of areas with the risk of explosion, and in areas with methane explosion hazard class "a", "b" or "c", and in excavation sites categorized as class "A" or "B" coal dust explosion hazard.
Sample cable marking: YnHKGSLY 9x1.5+1.5mm² 0.6/1 kV - 10-conductor cable, nominal power and protective conductor cross section: 1.5 mm², voltage rating: 0.6/1 kV
Product Images
التصنيف العام
5 نجوم
100%
4 نجوم
0
3 نجوم
0
نجمتان
0
نجمة واحدة
0
All Reviews
-
ETheir engineering team was extremely helpful in customizing the shielding for our specific industrial interference requirements.