YnHKGSLY Signal Mining Cable with Tin-plated Copper Wire Screen Non-flammable PVC Sheath 150/250V 300/500V 0.6/1KV
Βασικές Ιδιότητες
Τόπος καταγωγής:
Hebei, Κίνα
Επωνυμία Μάρκας:
Minfeng
Πιστοποίηση:
ISO,CE,IEC,TUV,KEMA
Αριθμός μοντέλου:
YnHKGSLY
Εμπορικά Ακίνητα
Ελάχιστη ποσότητα παραγγελίας:
100
Τιμή:
0.1-5
Όροι πληρωμής:
L/C,T/T
Δυνατότητα Προμήθειας:
100 χιλιόμετρα/εβδομάδα
Προδιαγραφές
| Conductor material: | χάλκινο, πολύκλωνο class 5 ac. PN-EN 60228 | Keywords: | ΑΠΟΤΕΛΕΙΑ ΑΠΟΤΕΛΕΙΑ |
| Sheath Material: | ειδικό, μη εύφλεκτο PVC | Hs Code: | 8544492100 |
| Voltagerating: | 150/250V 300/500V 0,6/1KV | Temperature: | -40°C έως 70°C |
Περιγραφή προϊόντων
150/250V 300/500V 0.6/1KV PVC YnHKGSLY Signal Tin-plated Copper Wire Screen Mining Cable
Mining signal cable with copper, multistranded, PVC insulated conductors, individual conductor screening, PVC sheath with increased flame propagation resistance.
Product Specifications
| Rated Voltage | 150/250V 300/500V 0.6/1 kV |
|---|---|
| Size | 9.5-38.2mm |
| Conductor Material | Copper |
| Insulation Material | Special PVC |
| Working Temperature | -40°C to 70°C |
| Jacket | PVC |
| Application | Industrial |
| Type | Low Voltage |
| Model Number | YnHKGSLY |
| Standard | PN-EN 60228 |
Technical Data
- Operating temperature: -40°C to 70°C
- Minimum installation temperature: -5°C
- Operating voltage: 150/250V, 300/500V, 0.6/1 kV
- Test voltage: 1.5 kV for 150/250V, 2.0 kV for 300/500V, 3.5 kV for 0.6/1 kV
- Minimum bending radius: 10 x Ø
Cable Construction
- Conductors: Copper, multi-stranded class 5 according to PN-EN 60228
- Insulation: Special PVC
- Conductor marking: Natural or black with digit print; yellow-green conductor in the outer layer
- Conductor screen: Tin-plated copper wire braid
- Outer sheath: Special, non-flammable PVC preventing flame propagation (tested according to PN-EN 60332-1 and PN-EN 60332-3-24, IEC 60332-3), oxygen index > 29
- Sheath color: Grey for 150/250V, 300/500V; Yellow for 0.6/1 kV
Application
Cables intended for supplying and controlling power control, safety and control systems in strip, open-pit and underground mines, out of areas with the risk of explosion, and in areas with methane explosion hazard class "a", "b" or "c", and in excavation sites categorized as class "A" or "B" coal dust explosion hazard.
Sample cable marking: YnHKGSLY 9x1.5+1.5mm² 0.6/1 kV - 10-conductor cable, nominal power and protective conductor cross section: 1.5 mm², voltage rating: 0.6/1 kV