2x10mm2 1x10+10mm2 Stranded Aluminum Cable 2 Cores Aerial Bundle Cable ABC Cable PE/XLPE Insulation 0.6/1KV Rated Voltage for
| Insulation: | XLPE | Origin: | China |
| Keywords: | ABC Cable | Trademark: | Minfeng |
| Conductor Material: | Aluminum | Cable Length: | 500-1000m |
| High Light: | 2x10mm2 stranded aluminum ABC cable,2 cores aerial bundle cable PE insulation,1x10+10mm2 ABC cable 0.6/1KV |
||
The 2x10mm² and 1x10+10mm² stranded aluminum aerial bundle cable (ABC cable) is designed for overhead power distribution. With PE or XLPE insulation and a rated voltage of 0.6/1 kV, it delivers reliable performance for service connections from pole-mounted transformers to user service heads. Suitable for use in the Yemen market and other regions requiring NFC 33-209 compliant conductors.
| Type | Insulated |
|---|---|
| Rated Voltage | 600/1000 V (0.6/1 kV) |
| Diameter | 6.5 mm (insulated conductor) |
| Conductor Material | Aluminum |
| Insulation Material | XLPE / PE |
| Conductor Type | Stranded |
| Application | Overhead |
| Place of Origin | Hebei, China |
| Model Number | 2x10mm ABC cable |
| Brand Name | Minfeng |
| Product Name | ABC Cable |
| Core | 2 cores aluminum cable |
| Standard | IEC 60502 / NFC 33-209 |
| Color | Black |
| Size | 10 mm² (6 AWG) |
| MOQ | 500 meters |
| Packaging | 500 m per roll |
The 2x10mm² ABC aerial bundle cable is used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance is made. It is suitable for use at 600 V or less phase-to-phase, with conductor temperatures not exceeding 75°C for polyethylene insulation or 90°C for cross-linked polyethylene (XLPE) insulation.
Aerial Bundled Conductors are manufactured to the National French Standard NFC 33-209.
| Phase Conductor | Aluminum conductor, round stranded compressed (RM) |
|---|---|
| Neutral Conductor | Alloy aluminum conductor, round stranded compressed (RM) |
| Insulation | XLPE |
| Assembly | Cores and neutral conductor stranded together in right-hand lay; additionally 1, 2 or 3 cores of reduced cross-section can be co-stranded |
| Parameter | Unit | Value |
|---|---|---|
| Rated voltage | kV | 0.6/1 |
| Test voltage | Veff kV/Hz | 4/50 |
| Laying temperature | °C | min. -5 |
| Operating temperature | °C | -15 ~ +90 |
| Conductor temperature | °C | max. +90 |
| Short-circuit temperature | °C/s | max. +250 / 5 |
| Bending radius (min.) | mm | 15 × Ø of cable |
| No. | Description | Unit | Data Provided |
|---|---|---|---|
| 1 | Standards Reference | — | IEC 60502-1, NFC 33-209 |
| 2 | Voltage | Volt | 600/1000 |
| 3 | Type of cable | mm² | 2x10 |
| 4 | Material of conductor | — | Stranded aluminum wire |
| 4a | Stranding — number of wires in conductor | No. | 7/1.35 |
| 4b | Approx. diameter of conductor | mm | 4.05 |
| 5 | Material of insulation | — | Black XLPE |
| 5a | Nominal thickness of insulation | mm | 1.2 |
| 5b | Approx. diameter of insulated conductor | mm | 6.5 |
| 6 | Approx. overall diameter of completed cable | mm | 13.0 |
| 7 | Maximum d.c. resistance of conductor at 20°C | ohm/km | 3.08 |
| 8 | Approx. weight of completed cable | kg/km | 93 |
Note: The technical data sheet above references the pre-assembled 2x16mm² torsade configuration in the original source; values shown reflect the 2x10mm² specification where applicable. Please confirm exact parameters with the manufacturer for your project requirements.
-
SWe’ve been ordering from this factory for three years. The consistency between batches is incredible; the quality of the first shipment matches the hundredth