0.6/1kV XLPE Stranded Copper 4x6sqmm 4x10mm2 4x16mm2 Galvanized Steel Wire Armored SWA Power Cable PVC Jacket for Underground
| Amour: | Steel Wire | Range Of Application: | XLPE Insulation |
| Core: | 4 | Marking: | Laser Printing |
| Voltage: | 0.6/1KV | Working Temperature: | 90℃ |
| Cable Standard: | BS 5467, IEC/EN 60502-1, IEC/EN 60228 , Flame Retardant According To IEC/EN 60332-1-2 | Origin: | Hebei, China |
| Cable Color: | Black Or Customized | Jacket: | PVC |
| Model Name: | SWA Armoured Cable | ||
| High Light: | XLPE copper SWA power cable,galvanized steel armored underground cable,PVC jacket 4x6sqmm power cable |
||
Galvanized Steel Wire Armored PVC Jacket Cable for Underground Applications
| Nominal Area (mm²) | Copper Conductor (Ω/km) | Aluminum Conductor (Ω/km) |
|---|---|---|
| 1.5 | 12.1 | - |
| 2.5 | 7.41 | 12.1 |
| 4 | 4.61 | 7.41 |
| 6 | 3.08 | 4.61 |
| 10 | 1.83 | 3.08 |
| 16 | 1.15 | 1.91 |
| 25 | 0.727 | 1.20 |
| 35 | 0.524 | 0.868 |
| 50 | 0.387 | 0.641 |
| 70 | 0.268 | 0.443 |
| 95 | 0.193 | 0.320 |
| 120 | 0.153 | 0.253 |
| 150 | 0.124 | 0.206 |
| 185 | 0.0991 | 0.164 |
| 240 | 0.0754 | 0.125 |
| 300 | 0.0601 | 0.100 |
| 400 | 0.0470 | 0.0778 |
| 500 | 0.0366 | 0.0605 |
| 630 | 0.0283 | 0.0469 |
This 4-core steel wire armoured SWA cable is designed for mains electricity in various applications, including underground laying, power networks, incoming mains to homes, and both external and internal uses.
The cable is suitable for direct burial, with steel wire armouring providing protection from external damage. XLPE insulation offers resistance to fluids, chemicals, and UV radiation, with excellent heat stability.
- BS 5467
- IEC/EN 60502-1
- IEC/EN 60228
- Flame Retardant according to IEC/EN 60332-1-2
- Conductors: Plain circular, compacted or shaped stranded copper or aluminium conductor
- Insulation: XLPE (cross-linked polyethylene) rated at 90°C
- Color Identification: 4 cores: Red, Yellow, Blue, Black (customizable)
- Assembly/Inner Sheath: Insulated conductors laid-up with non-hygroscopic fillers and PVC bedding
- Armour: Galvanized Steel Wires applied helically
- Sheath: Extruded PVC Type ST2 or Type 9
- Voltage: 600/1000V
- Operating Temperature: Maximum 90°C, minimum bending 0°C
- Maximum Short-circuit Temperature: 250°C (max. 5s)
- Minimum Bending Radius: ×20 cable diameter (armoured)
| Type | Specification | Outer Diameter | Insulation Thickness | Steel Wire Diameter | Sheath Thickness | Cable Outer Diameter | Approx. Weight | Ampacity (Air) | Ampacity (Soil) |
|---|---|---|---|---|---|---|---|---|---|
| XLPE/SWA | 4×4 RE | 2.24 | 0.7 | 1.25 | 1.8 | 19.1 | 770/670 | 37/28 | 46/35 |
| XLPE/SWA | 4×6 RE | 2.76 | 0.7 | 1.25 | 1.8 | 20.3 | 916/772 | 47/37 | 56/46 |
| XLPE/SWA | 4×10 CC | 3.8 | 0.7 | 1.6 | 1.8 | 22.3 | 1148/895 | 64/47 | 76/56 |
| XLPE/SWA | 4×16 CC | 4.8 | 0.7 | 1.6 | 1.8 | 24.5 | 1472/1070 | 84/64 | 98/76 |
| XLPE/SWA | 4×25 CC | 6.0 | 0.9 | 1.6 | 1.8 | 27.5 | 1942/1317 | 115/84 | 126/98 |
| XLPE/SWA | 4×35 CC | 7.0 | 0.9 | 1.6 | 1.8 | 29.5 | 2386/1521 | 141/115 | 152/126 |
| XLPE/SWA | 4×50 SM | 8.0 | 1.0 | 2.0 | 1.9 | 32.9 | 3209/2036 | 172/141 | 181/152 |
| XLPE/SWA | 4×70 SM | 9.5 | 1.1 | 2.0 | 2.1 | 36.7 | 4197/2502 | 218/172 | 222/181 |
| XLPE/SWA | 4×95 SM | 11.0 | 1.1 | 2.0 | 2.3 | 40.5 | 5362/3016 | 269/218 | 267/222 |
| XLPE/SWA | 4×120 SM | 12.4 | 1.2 | 2.5 | 2.4 | 45.3 | 6908/3940 | 313/269 | 305/267 |
| XLPE/SWA | 4×150 SM | 13.8 | 1.4 | 2.5 | 2.6 | 50.0 | 8327/4683 | 359/313 | 344/305 |
| XLPE/SWA | 4×185 SM | 15.4 | 1.6 | 2.5 | 2.7 | 54.2 | 10044/5466 | 405/359 | 383/344 |
| XLPE/SWA | 4×240 SM | 17.5 | 1.7 | 2.5 | 2.9 | 60.4 | 12672/6666 | 451/405 | 442/383 |
| XLPE/SWA | 4×300 SM | 19.6 | 1.8 | 2.5 | 3.1 | 65.7 | 15302/7795 | 497/451 | 461/422 |
Note: RE=circular solid, CC=compacted circular stranded, SM=sector shaped stranded
-
SA reliable, world-class manufacturer. If you are looking for high-tension cables that meet international safety standards, look no further.
-
KThe copper purity in these power cables is evident. We’ve seen a measurable improvement in conductivity compared to our previous domestic suppliers.