logo

NA2XY Triple 3-1X70mm2 XLPE Insulated Power Cable 0.6/1KV with Aluminum Conductor and PVC Sheath

Basic Properties
Place of Origin: Hebei, China
Brand Name: Minfeng
Certification: ISO,CE,IEC,TUV,KEMA
Model Number: NA2XY Triple
Trading Properties
Minimum Order Quantity: 100m
Price: 0.1-5
Payment Terms: L/C,T/T
Supply Ability: 100KM/Week
Specifications
Temperature Rating: 90℃ Conductor: Aluminum
Nominal Voltage: 0.6/1KV Model: NA2XY Triple
Sheathed: PVC Sheathed Voltage: 0.6/1KV
High Light:

0.6/1KV XLPE Insulated Power Cable

,

Aluminum Conductor NA2XY Triple Cable

,

PVC Sheathed Tripolar Power Cable

Product Description
NA2XY Triple 3-1X70mm² Power Cable Tripolar Type 0.6/1KV
Product Overview
Tripolar power cable with aluminum conductor, XLPE insulation, and PVC outer sheath. Rated for 600/1000V applications in construction and power transmission.
Type
Insulated
Rated Voltage
600/1000V
Conductor Material
Aluminium
Insulation Material
XLPE
Conductor Type
Stranded
Application
Construction
Core
3-1X70mm²
Package
Wooden
Applications
General use as power cable in low voltage distribution networks, industrial installations, buildings and operating centers. Suitable for fixed installations in indoor areas (trays, ducts), underground ducts or buried direct in ground, in dry or wet locations.
Standards Compliance
National: NTP-IEC 60228; NTP-IEC 60502-1
International: IEC 60228; IEC 60332-1; IEC 60332-3-24 Cat.C; IEC 60502-1; IEC 60684-2; IEC 60754-2; IEC 60811-1-1; IEC 60811-1-2; IEC 60811-1-3; IEC 60811-1-4; IEC 60811-2-1; IEC 60811-3-1; IEC 61034
Cable Construction
  • Conductor: Compact aluminium 1350, class 2
  • Insulation: Cross linked polyethylene XLPE
  • Outer sheath: Polyvinyl chloride PVC
  • Tape: Polyester tape
Colour: Insulation: Natural. Outer sheath: White, black, and red, or white and black.
Technical Characteristics
The cable has excellent electric properties. The cross-linked polyethylene insulation allows a higher power capacity current under any operation conditions, lower dielectric losses, high insulation resistance. The outer sheath has the following characteristics: Fire retardant, low emission dense smoke and halogen free. Sunlight resistance.
  • Rated voltage: 0.6/1kV
  • Test voltage: 3.5kV A.C.
  • Maximum conductor temperature: 90°C
  • Maximum operating temperature: 130°C
  • Short-circuit max. conductor temperature: 250°C
Design Parameters
No. Conductor x Section Min. Wires Insulation Thickness (mm) Sheath Thickness (mm) Outside Diameter (mm) Nominal Weight (kg/km)
3-1x16 6 0.7 1.4 9.0x27.2 318
3-1x25 6 0.9 1.4 10.6x31.8 450
3-1x35 6 0.9 1.4 11.6x34.7 540
3-1x50 6 1.0 1.4 13.1x39.3 720
3-1x70 12 1.1 1.4 15.0x45 960
3-1x95 15 1.1 1.5 16.8x50.4 1200
3-1x120 18 1.2 1.5 18.4x55.2 1500
3-1x150 18 1.4 1.6 20.5x61.6 1800
3-1x185 30 1.6 1.6 22.6x67.8 2190
3-1x240 34 1.7 1.7 25.2x75.6 2790
3-1x300 34 1.8 1.8 27.8x83.5 3420
3-1x400 53 2.0 1.9 31.4x94.3 4500
3-1x500 53 2.2 2.0 34.9x104.7 5400