4-Core Aluminum Conductor XLPE Insulated SWA Steel Wire Armored Power Cable with 16mm 25mm 35mm 50mm Armored Cables
| Armored: | Steel Wire | Sheath: | PVC |
| Voltage rating: | 0.6/1KV | Conductor: | Aluminum |
| Core: | 4 | Temperature rating: | 90°C |
| High Light: | 4-core aluminum conductor power cable,XLPE insulated armored power cable,steel wire armored SWA cable |
||
Available in 16mm, 25mm, 35mm, and 50mm armored cable sizes, this 4-core aluminum power cable features XLPE insulation and steel wire armoring for reliable power distribution applications.
- Conductor Material: Aluminum
- Insulation: XLPE (Cross-Linked Polyethylene)
- Jacket: PVC
- Application: Underground
- Type: Low Voltage
- Rated Voltage: 0.6/1KV
- Standard: IEC60502
- Model Number: 4x25 armored cable
- Brand: Minfeng
- Place of Origin: Hebei
Steel Wire Armoured (SWA) Cable is constructed with a black PVC sheath, XLPE insulation, aluminum conductors, and steel wire armoring. Designed for mains electricity in various applications including underground laying, power networks, and incoming mains to homes for both external and internal use.
This cable is suitable for direct burial, with the steel wire armoring providing additional protection from external damage. The XLPE insulation offers resistance to various fluids and chemicals, excellent heat stability, and UV resistance.
Complies with BS 5467, IEC/EN 60502-1, IEC/EN 60228, and flame retardant requirements according to IEC/EN 60332-1-2.
- Conductors: Plain circular, compacted or shaped stranded aluminum conductor (RE=circular solid, CC=compacted circular stranded, SM=sector shaped stranded)
- Insulation: XLPE (cross-linked polyethylene) rated at 90°C
- Armour: Galvanized Steel Wires applied helically over the bedding
- Sheath: Extruded PVC Type ST2 as per IEC 60502-1 or Type 9 as BS 6346/5467
Cables can be supplied with special flame retardant PVC outer sheath to comply with IEC 60332-3-22, IEC 60332-3-23, and IEC 60332-3-24 standards. Low Smoke Halogen Free (LSHF) materials are also available according to IEC 60502-1, BS 7211, BS 6724, or equivalent standards.
- Voltage: 600/1000V
- Operating Temperature: Maximum 90°C, minimum bending 0°C
- Maximum Short-Circuit Temperature: 250°C (max. 5s)
- Minimum Bending Radius: ×20 cable diameter (armoured)
| Type | Specification | Outer diameter | Nominal thickness of insulation | Diameter of steel wire | Nominal sheath thickness | Approx. Outer diameter of cable | Approx. Weight of cable | Ampacity of cable |
|---|---|---|---|---|---|---|---|---|
| XLPE/SWA | 4×4 RE | 2.24 | 0.7 | 1.25 | 1.8 | 19.1 | 770 | 37 |
| XLPE/SWA | 4×6 RE | 2.76 | 0.7 | 1.25 | 1.8 | 20.3 | 916 | 47 |
| XLPE/SWA | 4×10 CC | 3.8 | 0.7 | 1.6 | 1.8 | 22.3 | 1148 | 64 |
| XLPE/SWA | 4×16 CC | 4.8 | 0.7 | 1.6 | 1.8 | 24.5 | 1472 | 84 |
| XLPE/SWA | 4×25 CC | 6.0 | 0.9 | 1.6 | 1.8 | 27.5 | 1942 | 115 |
| XLPE/SWA | 4×35 CC | 7.0 | 0.9 | 1.6 | 1.8 | 29.5 | 2386 | 141 |
| XLPE/SWA | 4×50 SM | 8.0 | 1.0 | 2.0 | 1.9 | 32.9 | 3209 | 172 |
| XLPE/SWA | 4×70 SM | 9.5 | 1.1 | 2.0 | 2.1 | 36.7 | 4197 | 218 |
| XLPE/SWA | 4×95 SM | 11.0 | 1.1 | 2.0 | 2.3 | 40.5 | 5362 | 269 |
| XLPE/SWA | 4×120 SM | 12.4 | 1.2 | 2.5 | 2.4 | 45.3 | 6908 | 313 |
| XLPE/SWA | 4×150 SM | 13.8 | 1.4 | 2.5 | 2.6 | 50.0 | 8327 | 359 |
| XLPE/SWA | 4×185 SM | 15.4 | 1.6 | 2.5 | 2.7 | 54.2 | 10044 | 405 |
| XLPE/SWA | 4×240 SM | 17.5 | 1.7 | 2.5 | 2.9 | 60.4 | 12672 | 451 |
| XLPE/SWA | 4×300 SM | 19.6 | 1.8 | 2.5 | 3.1 | 65.7 | 15302 | 497 |
-
CWe’ve integrated these fiber optic cables into our latest data center project. The attenuation levels are remarkably low, exceeding our performance benchmarks.