logo

U1000 Aluminum XLPE Steel Tape Armoured ARVFV Cable 3x300+1x120+1x25mm 3x300+2x25mm 3x300+1C+P.E NFC 32-322 IEC 60502

Basic Properties
Place of Origin: Hebei, China
Brand Name: Minfeng
Certification: ISO,CE,IEC,TUV,KEMA
Model Number: ARVFV Cable
Trading Properties
Minimum Order Quantity: 100m
Price: 0.1-5
Payment Terms: L/C,T/T
Supply Ability: 100KM/Week
Specifications
Core Number: Multi Core Cable Mark: Printing Or Embossing
Conductor: Aluminum Operating Temp: 90 Degree
Packing Style: Steel/ Wooden Drum Cable Jacket: PVC
Voltage rating: 0.6/1kV Corporation: Minfeng Group
Product Description

Key attributes


Rated Voltage
1000V
Size
3X300+120+25
Conductor Material
Aluminum
Insulation Material
XLPE
Jacket
PVC
Place of Origin
China
Model Number
U1000 Cable ARVFV
Rated Voltage
1000V
Color
Customer Requirements
Standard
NFC 32-322 IEC 60502 Standard
Certification
IEC CE ISO CCC
MOQ
100
Packing
Wooden Drum
Size
3x300+1x120+1x25mm2 3x300+2x25mm2
Voltage
0.6/1kV
Cable name
ARVFV Cable
Armour type
Steel tape armored

1000 Cable ARVFV DSTA Armour Cable 3x300+1x120+1x25mm2  3x300+2x25mm2  3x300+1C+P.E  NFC 32-322 IEC 60502 Standard


U1000 Aluminum XLPE Steel Tape Armoured ARVFV Cable 3x300+1x120+1x25mm 3x300+2x25mm 3x300+1C+P.E NFC 32-322 IEC 60502U1000 Aluminum XLPE Steel Tape Armoured ARVFV Cable 3x300+1x120+1x25mm 3x300+2x25mm 3x300+1C+P.E NFC 32-322 IEC 60502

1. Product Application.

The main function of XLPE Insulated Power Cable is to transport electricity, which is suitable for use in power distribution networks or fixed installations for industrial equipments operating at rated voltage up to and including 0.6/1, 1.8/3, 3.6/6, 6/10, 8.7/10, 8.7/15, 12/20, 21/35, 26/35kV with alternating current(AC) 50Hz.This product is usually used under a normal used condition, which does not apply to some special conditions, such as overhead, underwater, ship, submarine, nuclear power station, etc.
XLPE insulated flame-retardant power cable, with good performance on preventing fire burning on the circuit, can avoid fire accidents and losses. It is suitable for used in the places where the cable needed to be fixed and installed at high density level, like subway, tunnels and high-rise buildings etc.
XLPE polyethylene insulated low-smoke zero-halogen flame-retardant power cables, a kind of environmental product, has good performance on flame-retardant, corrosion resistance and low-smoke, which is suitable to be laid and fixed in crowded places, such as subway, shopping mall or school etc.

2. Technique Features & Standard.

XLPE polyethylene insulated power cables, this product is manufactured by parasitical cross-linking procedure, the straight-chain polyethylene will be changed as network structure by use this method, which transformed thermoplastic material into thermosetting material. The working temperature is up to 90ºC, which can raise the cable current capacity highly. XLPE polyethylene insulated power cables, the product has good performance on electrical characteristic, heat resistance, chemical resistance, environmental stress cracking resistance and aging resistance, all which make the cable has a long useful life.

GB/12706-2008, IEC60502-1,IEC 60228,IEC60332 BS 5467,IS 1554 , IS 7098 ect.
we can also design and produce for special application requirement.

3. Operating Characteristics.

3.1 U0/U(Um) Rated Voltage of Cable

,0.6/1(1.2) No. of cores : 1 , 2 , 3, 4 , 5, 3+1 , 4+1 ,3+2 Nominal cross-section(mm2): 1.5~630
0.6/1(1.2), 1.8/3(3.6) 3.6/6(7.2), 6/6(7.2)-6/10 (12) 8.7/10(12) 8.7/15(17.5) 12/20(24) 18/30(36) 21/35(40.5) 26/35(40.5) kV
3.2 The rated Temperature of Conductor
a) The long-time operating temperature of conductor should not be higher than 90ºC
b) If the core is in short circuit, short circuit temperature of conductor should not exceed 160ºCnot more than 5sec.
3.3 Ambient Temperature
When installation, the ambient temperature should not be lower than 0ºC, otherwise the cable need be preheated.
3.4 Bending Radius
Bending radius of single core cable is 20(d+D) ±5%
Bending radius of multi-core cable is 15(d+D) ±5%
d: Actual diameter of the conductor (mm)
D: Actual outer diameter of cable sample (mm)

4. Specification of product.


Specification Outer diameter Nominal thickness of insulation Diameter of
steel wire
Nominal sheath thickness Approx. Outer diameter of cable Approx. Weight of cable Ampacity of cable
 Air Soil
CU AL Cu Al Cu Al
mm2 mm mm mm mm mm kg/km kg/km A A A A
4×4 RE 2.24 0.7 1.25 1.8 19.1 770 670 37 28 46 35
4×6 RE 2.76 0.7 1.25 1.8 20.3 916 772 47 37 56 46
4×10 CC 3.8 0.7 1.6 1.8 22.3 1148 895 64 47 76 56
4×16 CC 4.8 0.7 1.6 1.8 24.5 1472 1070 84 64 98 76
4×25 CC 6.0 0.9 1.6 1.8 27.5 1942 1317 115 84 126 98
4×35 CC 7.0 0.9 1.6 1.8 29.5 2386 1521 141 115 152 126
4×50 SM 8.0 1.0 2.0 1.9 32.9 3209 2036 172 141 181 152
4×70 SM 9.5 1.1 2.0 2.1 36.7 4197 2502 218 172 222 181
4×95 SM 11.0 1.1 2.0 2.3 40.5 5362 3016 269 218 267 222
4×120 SM 12.4 1.2 2.5 2.4 45.3 6908 3940 313 269 305 267
4×150 SM 13.8 1.4 2.5 2.6 50.0 8327 4683 359 313 344 305
4×185 SM 15.4 1.6 2.5 2.7 54.2 10044 5466 405 359 383 344
4×240 SM 17.5 1.7 2.5 2.9 60.4 12672 6666 451 405 442 383
4×300 SM 19.6 1.8 2.5 3.1 65.7 15302 7795 497 451 461 422
 Specification Outer diameter Nominal thickness of insulation Diameter of
steel wire
Nominal sheath thickness Approx. Outer diameter of cable Approx. Weight of cable Ampacity of cable
Air Soil
CU AL Cu Al Cu Al
mm2 mm mm mm mm mm kg/km kg/km A A A A
3×4+1×2.5 RE 2.24/1.78 0.7/0.7 1.6 1.8 17.4 649 558 37 28 46 35
3×6+1×4 RE 2.76/2.24 0.7/0.7 1.6 1.8 18.6 769 651 47 37 56 46
3×10+1×6 CC 3.8/2.76 0.7/0.7 1.6 1.8 20.3 989 763 64 47 76 56
3×16+1×10 CC 4.8/3.8 0.7/0.7 1.6 1.8 22.5 1270 906 84 64 98 76
3×25+1×16 CC 6.0/4.8 0.9/0.7 1.6 1.8 27.1 1857 1286 115 84 126 98
3×35+1×16 CC 7.0/4.8 0.9/0.7 1.6 1.8 29.3 2234 1483 141 115 152 126
3×50+1×25 SM 8.0/6.0 1.0/0.9 1.6 1.9 31.9 2828 1778 172 141 181 152
3×70+1×35 SM 9.5/7.0 1.1/0.9 2.0 2.0 36.3 3928 2420 218 172 222 181
3×95+1×50 SM 11.0/8.4 1.1/1.0 2.0 2.2 40.0 4956 2904 269 218 267 222
3×120+1×70 SM 12.4/10.0 1.2/1.1 2.5 2.3 44.4 6408 3760 313 269 305 267
3×150+1×70 SM 13.8/10.0 1.4/1.1 2.5 2.5 48.2 7456 4299 359 313 344 305
3×185+1×95 SM 15.4/11.5 1.6/1.1 2.5 2.6 52.4 9081 5062 405 359 383 344
3×240+1×120 SM 17.5/13.0 1.7/1.2 2.5 2.8 57.9 11292 6045 451 405 442 383
3×300+1×150 SM 19.6/14.5 1.8/1.4 2.5 3.0 63.0 13648 7106 497 451 461 422
Specification Outer diameter Nominal thickness of insulation Diameter of
steel wire
Nominal sheath thickness  Approx. Outer diameter of cable Approx. Weight of cable Ampacity of cable
Air Soil
CU AL Cu Al Cu Al
mm2 mm mm mm mm mm kg/km kg/km A A A A
5×4 RE 2.24 0.7 1.6 1.8 20.2 925 800 37 28 46 35
5×6 RE 2.76 0.7 1.6 1.8 21.6 1098 918 47 37 56 46
5×10 CC 3.8 0.7 1.6 1.8 23.8 1399 1083 64 47 76 56
5×16 CC 4.8 0.7 1.6 1.8 26.3 1791 1289 84 64 98 76
5×25 CC 6.0 0.9 1.6 1.8 33.5 2488 1706 115 84 126 98
5×35 CC 7.0 0.9 2.0 1.9 37.7 3339 2258 141 115 152 126
5×50 SM 8.0 1.0 2.0 2.0 38.2 3932 2468 172 141 181 152
5×70 SM 9.5 1.1 2.0 2.3 41.9 5122 3004 218 172 222 181
5×95 SM 11.0 1.1 2.5 2.4 47.9 7029 4096 269 218 267 222
5×120 SM 12.4 1.2 2.5 2.6 52.2 8487 4778 313 269 305 267
5×150 SM 13.8 1.4 2.5 2.7 55 10016 5460 359 313 344 305
5×185 SM 15.4 1.6 2.5 2.9 60.5 12218 6495 405 359 383 344
5×240 SM 17.5 1.7 2.5 3.1 66.5 15353 7845 451 405 442 383
5×300 SM 19.6 1.8 2.5 3.4 73.7 19419 10034 497 451 461 422



5. Construction.

Conductor shaped:RE=circular solid,CC=compacted circular stranded,SM=sector shaped stranded
Conductors: Plain circular, compacted or shaped stranded copper or aluminium conductor
Insulation: XLPE (cross-linked polyethylene) rated at 90°C
Colour identification
1 Core : Red or Black
2 Cores : Red, Black
3 Cores: Red, Yellow, Blue
4 Cores: Red, Yellow, Blue, Black
5 Cores: Red, Yellow, Blue, Black, Green
Above 5 Cores: Black Cores with White numerals
The above identifying can be changed as order
Assembly /Inner Sheath :Two, Three or Four insulated conductors are laid-up together with non-hygroscopic fillers and the assembly is bedded with an extruded layer of PVC. In case of non-armoured cables, this layer may be omitted
Armour:Aluminum/Galvanized Steel Wires, single core cables shall be Aluminium wire armour, Aluminum/Steel Tapes applied helically over the bedding of multi-core cables as per IEC 60502.
Outer Sheath:Outer sheath shall be of Extruded PVC Type ST2 as per IEC 60502-1 or Type 9 as BS 6346/5467.Special type of PVC sheathing material such as Fire Retardant PVC, Anti-Termite PVC, Anti-Rodent PVC, Sunlight resistant PVC, Oil Resistant PVC are available on special request. Also, special sheathing materials such as LLDPE, MDPE, HDPE, LSZH, and CPE are available on request.


 

Overall Rating
5.0
★★★★★
★★★★★
Based on 50 reviews recently
5 star
100%
4 star
0
3 star
0
2 star
0
1 star
0
All Reviews
  • C
    chang young kim
    South Korea Dec 16.2021
    ★★★★★
    ★★★★★