logo

Rf Feeder Cable 1/2" 1/4" 3/8" 7/8" 1-5/8" 1-1/4" Premium Attenuation Low-Loss Foam-Dielectric Coaxial Cable

Basic Properties
Place of Origin: Hebei, China
Brand Name: Minfeng
Certification: ISO,CE,IEC,TUV,KEMA
Model Number: Rf Feeder Cable
Trading Properties
Minimum Order Quantity: 100m
Price: 0.1-5
Payment Terms: L/C,T/T
Supply Ability: 100KM/Week
Specifications
Conductor material: Copper-Clad Aluminum Wire/Copper Tube Packing Style: Steel/ Wooden Drum
Operating Temp: -40 To 60℃ Trademark: Minfeng Cable Group
Diameter: 1/2" 1/4" 3/8" 7/8" 1-5/8" 1-1/4" Type: Rf Feeder Cable
Product Description

Key attributes


Type
Insulated
Rated Voltage
/
Diameter
1/2" 1/4" 3/8" 7/8" 1-5/8" 1-1/4"
Conductor Material
Copper-Clad Aluminum Wire/Copper Tube
Insulation Material
/
Working Temperature
-40 to 60℃
Conductor Type
Other
Application
Railway, Other, Building
Shape
Round
IP Level
/
Single Wire Size
1/2" 1/4" 3/8" 7/8" 1-5/8" 1-1/4"
Place of Origin
Hebei, China
Model Number
Rf Feeder Cable
Brand Name
Minfeng
Product name
rf feeder cable Rf Feeder Cable
Conductor
Copper-Clad Aluminum Wire/Copper Tube
size
1/2" 1/4" 3/8" 7/8" 1-5/8" 1-1/4"
Color
Black
FEATURES / BENEFITS
* Ultra Low AttenuationThe reduced attenuation of coaxial cable results in extremly efficient signal transfer in your RF system, especially at high frequencies.
* Complete ShieldingThe solid outer conductor of coaxial cable creates a continuous RFI/EMI shield that minimizes system interference.
* Low VSWRSpecial low VSWR versions of coaxial cables contribute to low system noise.
* Outstanding Intermodulation Performance coaxial cable's solid inner and outer conductors virtually eliminate intermods. Intermodulation performance is also confirmed with state-of-the-art equipment at the factory.
* High Power RatingDue to their low attenuation, outstanding heat transfer properties and temperature stabilized dielectric materials, cable provides safe long term operating life at high transmit power levels.
* Wide Range of ApplicationTypical areas of application are: feedlines for broadcast and terrestrial microwave antennas, wireless cellular, PCS and ESMR base stations, cabling of antenna arrays, and radio equipment interconnects
Product Description
Rf Feeder Cable 1/2" 1/4" 3/8" 7/8" 1-5/8" 1-1/4" Premium Attenuation Low-Loss Foam-Dielectric Coaxial Cable

LCF12-50J 1/2" Low-Loss Foam-Dielectric Coaxial Cable

STRUCTURE Size 1/2 Inner Conductor Diameter mm (in) 4.8 (0.189) Inner Conductor Material Copper-Clad Aluminum Wire Dielectric Diameter mm (in) 11.3 (0.445) Dielectric Material Foam Polyethylene Outer Conductor Diameter mm (in) 13.8 (0.543) Outer Conductor Material Corrugated Copper Jacket Diameter mm (in) 15.8 (0.622) Jacket Material Black Polyethylene TESTING AND ENVIRONMENTAL Phase Stabilized Phase stabilized and phase matched cables and accessories are available upon request. Compliance DIN EN ISO 9001:2015 ISO 14001:2015 RoHS 2011/65/EU - China RoHS SJ/T 11364-2006 REACH (EC 1907/2006) Installation Temperature °C(°F) -40 to 60 (-40 to 140) Storage Temperature °C (°F) -70 to 85 (-94 to 185) Operation Temperature °C(°F) -50 to 85 (-58 to 185)
ELECTRICAL SPECIFICATIONS Impedance Ω 50 +/- 1 Maximum Frequency GHz 8.8 Velocity % 87 Capacitance pF/m (pF/ft) 76 (23.2) Inductance uH/m (uH/ft) 0.19 (0.058) Peak Power Rating kW 38 RF Peak Voltage Volts 1950 Jacket Spark Volt RMS 8000 Inner Conductor dc Resistance Ω/1000 m (Ω/1000 ft) 1.62 (0.5) Outer Conductor dc Resistance Ω/1000 m (Ω/1000 ft) 3.55 (1.08) Passive Intermodulation PIM typ. dBc -160 Return Loss (VSWR) Performance Standard 20dB (1.222) / Premium 23/24dB (1.152/1.135) on specified frequencies MECHANICAL SPECIFICATIONS Cable Weight, Nominal kg/m (lb/ft) 0.18 (0.125) Minimum Bending Radius, Single Bend mm (in) 70 (2.756) Minimum Bending Radius, Repeated Bends mm (in) 125 (4.921) Bending Moment Nm (lb-ft) 6.5 (4.79) Tensile Strength N (lb) 1050 (236) Recommended / Maximum Clamp Spacing m (ft) 0.6 / 1 (2 / 3.25)
Rf Feeder Cable 1/2" 1/4" 3/8" 7/8" 1-5/8" 1-1/4" Premium Attenuation Low-Loss Foam-Dielectric Coaxial Cable
LCF14-50J 1/4" Low-Loss Foam-Dielectric Coaxial Cable
STRUCTURE Size 1/4 Inner Conductor Diameter mm (in) 2.4 (0.094) Inner Conductor Material Copper-Clad Aluminum Wire Dielectric Diameter mm (in) 6 (0.236) Dielectric Material Foam Polyethylene Outer Conductor Diameter mm (in) 7.5 (0.295) Outer Conductor Material Corrugated Copper Jacket Diameter mm (in) 10 (0.394) Jacket Material Black Polyethylene
TESTING AND ENVIRONMENTAL Phase Stabilized Phase stabilized and phase matched cables and accessories are available upon request. Compliance DIN EN ISO 9001:2015 ISO 14001:2015 RoHS 2011/65/EU - China RoHS SJ/T 11364-2006 REACH (EC 1907/2006) Installation Temperature °C(°F) -40 to 60 (-40 to 140) Storage Temperature °C (°F) -70 to 85 (-94 to 185) Operation Temperature °C(°F) -50 to 85 (-58 to 185)
ELECTRICAL SPECIFICATIONS Impedance Ω 50 +/- 1.5 Maximum Frequency GHz 15.8 Velocity % 83 Capacitance pF/m (pF/ft) 80 (24) Inductance uH/m (uH/ft) 0.205 (0.063) Peak Power Rating kW 10.9 RF Peak Voltage Volts 1050 Jacket Spark Volt RMS 5000 Inner Conductor dc Resistance Ω/1000 m (Ω/1000 ft) 6.1 (1.86) Outer Conductor dc Resistance Ω/1000 m (Ω/1000 ft) 4.4 (1.34) Passive Intermodulation PIM typ. dBc -160 Return Loss (VSWR) Performance Standard 20dB (1.222) / Premium 23/24dB (1.152/1.135) on specified frequencies MECHANICAL SPECIFICATIONS Cable Weight, Nominal kg/m (lb/ft) 0.095 (0.064) Minimum Bending Radius, Single Bend mm (in) 40 (1.575) Minimum Bending Radius, Repeated Bends mm (in) 85 (3.346) Bending Moment Nm (lb-ft) 1.9 (1.4) Tensile Strength N (lb) 890 (200) Recommended / Maximum Clamp Spacing m (ft) 0.5 / 1 (1.75 / 3.25)
Rf Feeder Cable 1/2" 1/4" 3/8" 7/8" 1-5/8" 1-1/4" Premium Attenuation Low-Loss Foam-Dielectric Coaxial Cable

LCF38-50J 3/8" Low-Loss Foam-Dielectric Coaxial Cable

STRUCTURE Size 3/8 Inner Conductor Diameter mm (in) 3.1 (0.122) Inner Conductor Material Copper-Clad Aluminum Wire Dielectric Diameter mm (in) 7.2 (0.283) Dielectric Material Foam Polyethylene Outer Conductor Diameter mm (in) 9.5 (0.374) Outer Conductor Material Corrugated Copper Jacket Diameter mm (in) 11.2 (0.441) Jacket Material Black Polyethylene TESTING AND ENVIRONMENTAL Phase Stabilized Phase stabilized and phase matched cables and accessories are available upon request. Compliance DIN EN ISO 9001:2015 ISO 14001:2015 RoHS 2011/65/EU - China RoHS SJ/T 11364-2006 REACH (EC 1907/2006) Installation Temperature °C(°F) -40 to 60 (-40 to 140) Storage Temperature °C (°F) -70 to 85 (-94 to 185) Operation Temperature °C(°F) -50 to 85 (-58 to 185)
ELECTRICAL SPECIFICATIONS Impedance Ω 50 +/- 1.5 Maximum Frequency GHz 13.5 Velocity % 88 Capacitance pF/m (pF/ft) 76 (23.2) Inductance uH/m (uH/ft) 0.19 (0.058) Peak Power Rating kW 15.4 RF Peak Voltage Volts 1240 Jacket Spark Volt RMS 5000 Inner Conductor dc Resistance Ω/1000 m (Ω/1000 ft) 3.8 (1.16) Outer Conductor dc Resistance Ω/1000 m (Ω/1000 ft) 2.9 (0.88) Passive Intermodulation PIM typ. dBc -160 Return Loss (VSWR) Performance Standard 20dB (1.222) / Premium 23/24dB (1.152/1.135) on specified frequencies MECHANICAL SPECIFICATIONS Cable Weight, Nominal kg/m (lb/ft) 0.13 (0.087) Minimum Bending Radius, Single Bend mm (in) 50 (2) Minimum Bending Radius, Repeated Bends mm (in) 95 (4) Bending Moment Nm (lb-ft) 1.9 (1.4) Tensile Strength N (lb) 530 (119) Recommended / Maximum Clamp Spacing m (ft) 0.5 / 1 (1.75 / 3.25)
Rf Feeder Cable 1/2" 1/4" 3/8" 7/8" 1-5/8" 1-1/4" Premium Attenuation Low-Loss Foam-Dielectric Coaxial Cable

LCF78-50JA 7/8" Premium Attenuation Low-Loss Foam-Dielectric Coaxial Cable

STRUCTURE Size 7/8 Inner Conductor Diameter mm (in) 9.1 (0.358) Inner Conductor Material Copper Tube Dielectric Diameter mm (in) 21.5 (0.846) Dielectric Material Foam Polyethylene Outer Conductor Diameter mm (in) 25.2 (0.992) Outer Conductor Material Corrugated Copper Jacket Diameter mm (in) 27.8 (1.094) Jacket Material Black Polyethylene TESTING AND ENVIRONMENTAL Phase Stabilized Phase stabilized and phase matched cables and assemblies are available upon request. Compliance DIN EN ISO 9001:2015 ISO 14001:2015 RoHS 2011/65/EU - China RoHS SJ/T 11364-2006 REACH (EC 1907/2006) Installation Temperature °C(°F) -40 to 60 (-40 to 140) Storage Temperature °C (°F) -70 to 85 (-94 to 185) Operation Temperature °C(°F) -50 to 85 (-58 to 185)
ELECTRICAL SPECIFICATIONS Impedance Ω 50 +/- 1 Maximum Frequency GHz 5 Velocity % 88 Capacitance pF/m (pF/ft) 74 (22.5) Inductance uH/m (uH/ft) 0.185 (0.056) Peak Power Rating kW 85 RF Peak Voltage Volts 2920 Jacket Spark Volt RMS 8000 Inner Conductor dc Resistance Ω/1000 m (Ω/1000 ft) 2.04 (0.62) Outer Conductor dc Resistance Ω/1000 m (Ω/1000 ft) 1.55 (0.472) Passive Intermodulation PIM typ. dBc -160 Return Loss (VSWR) Performance Standard 20dB (1.222) / Premium 23/24dB (1.152/1.135) on specified frequencies MECHANICAL SPECIFICATIONS Cable Weight, Nominal kg/m (lb/ft) 0.39 (0.262) Minimum Bending Radius, Single Bend mm (in) 120 (5) Minimum Bending Radius, Repeated Bends mm (in) 250 (10) Bending Moment Nm (lb-ft) 13 (10) Tensile Strength N (lb) 1440 (324) Recommended / Maximum Clamp Spacing m (ft) 0.8 / 1 (2.75 / 3.25)
Rf Feeder Cable 1/2" 1/4" 3/8" 7/8" 1-5/8" 1-1/4" Premium Attenuation Low-Loss Foam-Dielectric Coaxial Cable

LCFS114-50CPR 1-1/4" Premium Attenuation Low-Loss Foam-Dielectric Coaxial Cable

Structure Cable Type Foam-Dielectric, Corrugated Size 1-1/4 Jacket Option Black Inner Conductor Diameter mm (in) 13.1 (0.52) Inner Conductor Material Copper Tube Dielectric Diameter mm (in) 32.7 (1.29) Dielectric Material Foam Polyethylene Outer Conductor Diameter mm (in) 35.9 (1.41) Outer Conductor Material Corrugated Copper Jacket Diameter mm (in) 39 (1.54) Jacket Material Polyethylene, PE, Metalhydroxite Filling Testing and Environmental Fire Performance Flame Retardant, LS0H Installation Temperature °C(°F) -15 to 60 (5 to 140) Storage Temperature °C (°F) -70 to 85 (-94 to 185) Operation Temperature °C(°F) -50 to 85 (-58 to 185)
Electrical Specifications Impedance Ω 50 +/- 1 Maximum Frequency GHz 3.7 Velocity % 89 Capacitance pF/m (pF/ft) 75 (22.9) Inductance uH/m (uH/ft) 0.188 (0.057) Peak Power Rating kW 176 RF Peak Voltage Volts 4200 Jacket Spark Volt RMS 10000 Inner Conductor dc Resistance Ω/1000 m (Ω/1000 ft) 0.83 (0.25) Outer Conductor dc Resistance Ω/1000 m (Ω/1000 ft) 0.73 (0.22) Return Loss (VSWR) Performance Standard (for 40-2700, 3300-3700 MHz) or Premium Min. Return Loss (Max. VSWR) dB (VSWR) Standard 20 (1.222), Premium 24 (1.135)/ 23 (1.152) Phase Stabilized Phase stabilized and phase matched cables and assemblies are available upon request. Temperature & Power Standard Mechanical Specifications Cable Weight, Nominal kg/m (lb/ft) 0.97 (0.65) Minimum Bending Radius, Single Bend mm (in) 200 (8) Minimum Bending Radius, Repeated Bends mm (in) 380 (15) Bending Moment Nm (lb-ft) 43 (32) Tensile Strength N (lb) 2490 (560) Recommended / Maximum Clamp Spacing m (ft) 1 / 1.2 (3.25 / 4)
Rf Feeder Cable 1/2" 1/4" 3/8" 7/8" 1-5/8" 1-1/4" Premium Attenuation Low-Loss Foam-Dielectric Coaxial Cable

LCF158-50CPR 1-5/8" Premium Attenuation Low-Loss Foam-Dielectric Coaxial Cable

Structure Cable Type Foam-Dielectric, Corrugated Size 1-5/8 Jacket Option Black Inner Conductor Diameter mm (in) 17.6 (0.69) Inner Conductor Material Corrugated Copper Tube Dielectric Diameter mm (in) 42.4 (1.67) Dielectric Material Foam Polyethylene Outer Conductor Diameter mm (in) 46.4 (1.83) Outer Conductor Material Corrugated Copper Jacket Diameter mm (in) 50.2 (1.98) Jacket Material Polyethylene, PE, Metalhydroxite Filling Testing and Environmental Fire Performance Flame Retardant, LS0H Installation Temperature °C(°F) -15 to 60 (5 to 140) Storage Temperature °C (°F) -70 to 85 (-94 to 185) Operation Temperature °C(°F) -50 to 85 (-58 to 185)
Electrical Specifications Impedance Ω 50 +/- 1 Maximum Frequency GHz 2.75 Velocity % 90 Capacitance pF/m (pF/ft) 74 (22.5) Inductance uH/m (uH/ft) 0.185 (0.056) Peak Power Rating kW 310 RF Peak Voltage Volts 5600 Jacket Spark Volt RMS 10000 Inner Conductor dc Resistance Ω/1000 m (Ω/1000 ft) 1.3 (0.4) Outer Conductor dc Resistance Ω/1000 m (Ω/1000 ft) 0.47 (0.14) Return Loss (VSWR) Performance Stamdard (for 40-2700 MHz) or Premium Min. Return Loss (Max. VSWR) dB (VSWR) Standard 20 (1.222), Premium 24 (1.135)/ 23 (1.152) Phase Stabilized Phase stabilized and phase matched cables and assemblies are available upon request. Temperature & Power Standard Mechanical Specifications Cable Weight, Nominal kg/m (lb/ft) 1.25 (0.84) Minimum Bending Radius, Single Bend mm (in) 200 (8) Minimum Bending Radius, Repeated Bends mm (in) 500 (20) Bending Moment Nm (lb-ft) 42 (31) Tensile Strength N (lb) 2500 (562) Recommended / Maximum Clamp Spacing m (ft) 1.2 / 1.5 (4 / 5)
Specification
Frequency, MHz
dB per 100m
dB per 100ft
Power, kW
100
2.18
0.66
3.45
200
3.12
0.95
2.41
450
4.77
1.45
1.57
700
6.03
1.83
1.24
800
6.48
1.97
1.16
900
6.91
2.1
1.09
1800
10.09
3.07
0.74
2000
10.7
3.26
0.7
2200
11.28
3.44
0.67
2400
11.84
3.61
0.63
2700
12.66
3.86
0.59
3000
13.43
4.01
0.56
3500
14.67
4.47
0.51
4000
15.84
4.83
0.47
5000
18.03
5.51
0.42
6000
20.07
6.14
0.37
7000
22
6.73
0.34
8800
25,24
7.73
0.3
Overall Rating
5.0
★★★★★
★★★★★
Based on 50 reviews recently
5 star
100%
4 star
0
3 star
0
2 star
0
1 star
0
All Reviews
  • M
    marcos casanova vara
    Peru Aug 24.2024
    ★★★★★
    ★★★★★
    In an industry plagued by shortages, this manufacturer’s ability to maintain a steady lead time is a massive asset to our supply chain.