High Voltage ACSR Bare Conductor 266.8 MCM Aluminium Overhead Line Conductor

Basic Properties
Place of Origin: Hebei, China
Brand Name: Minfeng
Certification: ISO,CE,IEC,TUV,KEMA
Model Number: ACSR
Trading Properties
Minimum Order Quantity: 100
Price: 0.1-5
Payment Terms: L/C,T/T
Supply Ability: 100KM/Week
Specifications
Exoprt Experience: South America, Africa, Middle East Ect Conductor Shape: Circular
Free Sample: Yes Insulating Material: Bare
Cores No: 1-36 Application: Power Transmission
Material Of Conductor: Aluminium
High Light:

ACSR Bare Conductor

,

High Voltage Bare Conductor

,

ACSR Aluminium Overhead Line Conductor

Product Description
ACSR Bison 266.8 MCM ACSR Bare Conductor 100mm² 795 MCM CONDOR and ACSR 954 MCM Rail Conductor
Product Overview
Conductor Material Aluminum
Insulation Material No insulation
Jacket No sheath
Application Overhead
Type High Voltage
Place of Origin Hebei, China
Standard IEC/ASTM/BS/DIN
Export Markets Global market
AAC Application
AAC is used mainly in urban areas where spacing is short and supports are close. All aluminium conductors are made up of one or more strands of aluminium wire depending on the end usage. AAC is also used extensively in coastal regions because it has a high degree of corrosion resistance.
AAC Standards
Minfeng AAC conductors are manufactured in accordance with the following standards:
  • ASTM B230, NTC 360: Aluminum 1350-H19 Wire
  • ASTM B231, NTC 308: Concentric-Lay-Stranded Aluminum 1350 Conductors
  • IEC 228 for sizes in mm²
ACSR Application
ACSR conductors have been widely used in power transmission lines with various voltage levels, because they have such good characteristics as simple structure, convenient insulation and maintenance, low cost, and large transmission capacity. They are also suitable for laying across rivers, valleys, and places where special geographical features exist.
ACSR Standards
  • ASTM B-232
  • BS EN-50182
  • CSAC 61089
  • AS/NZS 3607
  • DIN 48204
  • IEC 61089
  • GB/T 1179
  • JIS 3110
  • ASTM B711
AAAC Application
The conductor is designed to get better strength-to-weight ratio and offer improved electrical properties, excellent sag-tension characteristics, and superior corrosion resistance when compared with ACSR. As compared to a conventional ACSR conductor, the lighter weight, comparable strength & current carrying capacity, lower electrical losses, and superior corrosion resistance have given AAAC wide acceptance in distribution and medium & high voltage transmission lines.
AAAC Standards
All Aluminum-Alloy Conductors (AAAC) can be supplied to meet various International Standards as follows:
  • IEC 61089
  • ASTM B 399
  • BS EN 50182
  • DIN 48201 / 6
High Voltage ACSR Bare Conductor 266.8 MCM Aluminium Overhead Line Conductor 0 High Voltage ACSR Bare Conductor 266.8 MCM Aluminium Overhead Line Conductor 1 High Voltage ACSR Bare Conductor 266.8 MCM Aluminium Overhead Line Conductor 2
Bare Conductor Technical Parameters
Code Word Size (AWG or kcmil) Stranding Individual Wire Diameter (inches) Complete Cable Diameter (inches) Weight Per 1000ft. (lbs.) Rated Strength (lbs.)
Peachbell 6 7 0.0612 0.184 25 563
Rose 4 7 0.0772 0.232 39.2 881
Iris 2 7 0.0974 0.292 62.3 1350
Pansy 1 7 0.1093 0.328 78.5 1640
Pop 1/0 7 0.1228 0.368 99.1 1990
Geranium 1/0 19 0.0745 0.371 99 --
Aster 2/0 7 0.1309 0.416 124.9 2510
Buttercup 2/0 19 0.0837 0.416 125 --
Phlox 3/0 7 0.1548 0.464 157.5 3040
Primrose 3/0 19 0.094 0.467 158 --
Oxlip 4/0 7 0.1739 0.522 198.7 3830
Sunflower 4/0 19 0.1055 0.525 198 --
Code Word Size (AWG or KCMIL) Stranding (Al/Stl) Diameter (inches) Weight Per 1000ft (lbs.)
6Turkey 6/6 6/1 0.198 36.1
Swan 4 6/1 0.25 57.4
Swanate 4 7/1 0.257 67
Sparrow 2 6/1 0.316 91.3
Sparate 2 7/1 0.325 106.7
Robin 1 6/1 0.355 115.2
Raven 1/0 6/1 0.398 145.3
Quail 2/0 6/1 0.447 183.1
Pigeon 3/0 6/1 0.502 230.8
Penguin 4/0 6/1 0.563 291.1
Code Word Size (KCMIL) Stranding Diameter (ins.) Weight Per 1000 Feet (lbs.) Rated Strength (lbs.)
Akron 30.58 7 0.198 28.5 1110
Alton 48.69 7 0.25 45.4 1760
Ames 77.47 7 0.316 72.2 2800
Azusa 123.3 7 0.398 115 4460
Anaheim 155.4 7 0.447 144.9 5390
Amherst 195.7 7 0.502 182.5 6790
Alliance 246.9 7 0.563 230.2 8560
Overall Rating
5.0
★★★★★
★★★★★
Based on 50 reviews recently
5 star
100%
4 star
0
3 star
0
2 star
0
1 star
0
All Reviews
  • M
    marcos casanova vara
    Peru Aug 24.2024
    ★★★★★
    ★★★★★
    In an industry plagued by shortages, this manufacturer’s ability to maintain a steady lead time is a massive asset to our supply chain.
  • C
    chang young kim
    South Korea Dec 16.2021
    ★★★★★
    ★★★★★
    We’ve integrated these fiber optic cables into our latest data center project. The attenuation levels are remarkably low, exceeding our performance benchmarks.
  • E
    Eglis Sirithatthamrong
    Thailand Nov 25.2021
    ★★★★★
    ★★★★★
    Their engineering team was extremely helpful in customizing the shielding for our specific industrial interference requirements.