TUV Certificated DC 1500V Solar PV Cable With EN50618 Standard
| Free Sample: | Avaliable | Rate Voltage: | 1KV AC 1500V DC |
| Insulation: | XLPO | Male End Type: | CEE, CEE/16 3 Prong Schuko Plug |
| Trademark: | Minfeng | Condutor: | Tinned Copper |
| High Light: | DC 1500V Solar PV Cable,Solar PV Cable EN50618 |
||
Single core flexible cables suited for photovoltaic and solar systems with cross-linked polymer insulation and halogen free sheath.
| Conductor Material | Copper |
| Insulation Material | XLPE |
| Application | Construction |
| Type | Low Voltage |
| Voltage | AC 1000V / DC 1500V |
| Cross Section | 1.5mm², 2.5mm², 4.0mm², 6.0mm², 10mm², 16mm² |
| Conductor | Tinned flexible copper wire |
| Standard | EN50618 |
| Certificate | TUV Certificate |
For the cabling between the solar modules and as extension cable between the module strings and the DC/AC inverter. Suitable for gable and flat roof photovoltaic systems, photovoltaic plants and solar parks, flexible or building-integrated PV systems including connecting photovoltaic power supply systems. Can be used indoor & outdoor for flexible and fixed installations with high mechanical strength in extreme weather conditions from -40°C to 120°C maximum. Ozone & UV resistant with full protection against Ultra Violet rays.
- Weather/UV-resistant according to HD 605/A1
- Ozone-resistant according to EN 50396
- Halogen-free and flame-retardant
- Good notch and abrasion resistance
- XLS-R = X-Linked Standard - Reduced Proven electron beam cross-linked quality
- Cold Flexibility
- Long Life about > 25 years
- Suitable to common connector type
- Nominal voltage U0/U: AC 600/1000V - 720/1200V & DC 900/1800V
- Max. permitted DC voltage: 1.8 kV (Conductor/Conductor, non-earthed system)
- Working voltage: According to TÜV 2 PfG 1169 DC 1000V
- Test voltage: AC 6.5 kV for 5 min & DC 15 KV
- Voltage resistance tests according to EN 50395
- Insulation Resistance: 1000 m-Ω/km minimum
- Ambient temperature: -40°C to 90°C (25 year life)
- Conductor temperature: 120°C max.
- Short Circuit temperature: 200°C for 5 sec.
- Thermal Endurance Test: According to EN 60216-2
- High Temperature Pressure Test: According to EN 60811-3-1
- Damp-Heat Test: According to EN 60068-2-78 (1000 hrs. at 90°C with 85% humidity)
- Minimum Bending Radius: 4 to 5 x Outer Diameter
- Dynamic Penetration: According to requirement of Cables for PV systems 2 Pfg 1169/08.2007 Annex F
- Notch Propagation: According to 2 Pfg 1169/08.2007 Annex G
- Tensile Strength: 15 N/mm² for insulation and 12.5 N/mm² for sheathing (EN60811)
- Elongation of Insulation and sheathing: 125% (EN60811)
- Shore Hardness 85 (DIN EN 53505)
- Shrinkage: 2% at 120°C (EN 60811-1-3)
The cables are RoHS (Restriction of certain Hazardous Substances) compliant as per EU Directives 2002/95/EC
- Mineral Oil Resistance: EN 60811-2-1 & VDE 0473-811-2-1
- Ozone Resistance: EN 50396 part 8.1.3 Method B
- Weathering-UV Resistance: HD 605/A1 or DIN 53367
- Ammonia resistant: 30 days in saturated ammonia atmosphere
- Very good resistance to oil and chemicals
- High wear and robust, abrasion resistant
- Acid & Alkaline Resistance: EN 60811-2-1 (Oxalic acid and sodium hydroxide)
- Flame retardant: IEC 60332-1-2 & VDE 0482 Part 332-1-2
- Low smoke emission < 20% (ASTM D-2843, BS EN 50268, VDE 0482 Part 266-2-5)
- Halogen free: EN 50267-2-1/-2, IEC 60754-2
- Acid gas emission not more than 0.5% (IEC 60754-1)
- pH minimum 4.3 (IEC 60754-2)
- Conductivity maximum 10 (IEC 60754-2)
- Toxicity: EN 50305, ITC-index < 3
- Flame Propagation: BS EN 50265, EN50266 (IEC 60332)
- Light Transmission: < 60% (DIN EN 50268-2)
- Corrositivity: DIN EN 50267-2-2
- Ozone resistance: DIN EN 50396 test type B, HD 22.2 test type B
- UV resistance: UL 1581 (Xeno-Test), ISO 4892-2 (Method A) and HD 506/A1-2.4.20
- Absorption of water (gravimetric): DIN VDE 0473-811-1-3, DIN EN 60811-1-3
- For use in solar power applications
- Rated 90℃ for exposed or concealed wiring in wet or dry locations
- Rated for direct burial conduit
- Stranded copper conductors with single layer
- Bare or tinned conductors
- XLPE insulation
- -40°C to +90°C temperature range
- Sunlight resistant
- RoHS compliant
- Direct burial rated
Copper Photovoltaic Wire meets the requirements of:
- UL Subject 4703 for TYPE PV
- UL 44 for TYPE RHW-2
- UL 854 for TYPE USE-2
- 600V / 1000V configurations available upon request
- Cable tray use compatible
-