XLPE Insulated ABC Cable 12.7/22kV Rated Voltage Aluminum Conductor Overhead Power Cable
| Range Of Application: | Overhead | Wire Core Material: | Aluminium |
| Sample: | Freely Supplied | Product Time: | 10days |
| Model No: | ABC | Quality: | Top |
| High Light: | XLPE Insulated ABC Cable,ABC Cable 22kV,Aluminum Conductor Overhead Power Cable |
||
A new type of aerial cable for power transmission, extensively used in overhead power transmission lines. Improves the safety and reliability of electrical networks.
- Rated Voltage: 12.7/22kV
- Available Sizes: 35, 50, 70, 95, 120mm²
- Conductor Material: Aluminum
- Insulation Material: PVC, XLPE, and PE
- Jacket: Bare ABC Cable
- Application: Electric Distribution System
- Type: Low Voltage and Medium Voltage
- Color: Black Anti-UV
- Characteristics: LOSH, Anti-UV
Conductor: Aluminum, Alloy Aluminum
Insulation: XLPE, PE
- 2 x 16 mm²
- 3*25 mm²+54.6 mm²+16 mm²
- 2 x 25 mm²
- 3*35 mm²+54.6 mm²+16 mm²
- 2 x 35 mm²
- 3*50 mm²+54.6 mm²+16 mm²
- 2 x 50 mm²
- 3*70 mm²+54.6 mm²+16 mm²
- 4 x 16 mm²
- 3*70 mm²+70 mm²+16 mm²
- 4 x 25 mm²
- 3*95 mm²+70 mm²+16 mm²
- 4 x 35 mm²
- 3*120 mm²+70 mm²+16 mm²
Standards: IEC60502, IEC61089; NF C33-209; GB 12527-9; ASTM B231, ASTM B232, BS215; DIN48201, DIN48204
Certifications: ISO9001, ISO14001, OASHA8001
We can also manufacture ABC cable according to customer's special requirements.
Used for transmitting electric power overhead, extensively used in rebuilding of urban and forest region electrical networks. Improves the safety and reliance of electrified wire netting. Suitable for voltages of 600V phase-to-phase or less at conductor temperatures not exceeding 75℃ for polyethylene insulated conductors or 90℃ for cross-linked polyethylene (XLPE) insulated conductors.
Concentric strand aluminum wires as phase conductor; AAAC (all aluminum alloy conductors) or ACSR (aluminum conductor steel reinforced) as messenger (Neutral) core; Phase conductor is insulated by XLPE or HDPE or PVC.
Meets or exceeds the following specifications:
- Aluminum Wire, 1350-H19 for Electrical Purposes
- Aluminum Conductors, Concentric-Lay-Stranded
- Aluminum Conductor, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
- Concentric-Lay-Stranded 6201-T81 Conductors
- Compressed Round Stranded Aluminum Conductors Using Single Input Wire
Meets or exceeds all applicable requirements of ANSI/ICEA S-76-474
Service drop cables cover three main types:
- Duplex Service Drop
- Triplex Service Drop
- Quadruplex Service Drop
Basic construction includes:
- 3 power cores consisting of standard aluminum conductors, insulated with XLPE insulation
- One sheath lighting aluminum conductor with XLPE insulation (optional)
- One messenger Al-alloy conductor (bare or covered)
The messenger conductor can be of galvanized steel wire. Purpose of messenger wire:
- Acts as load bearing wire
- Acts as earth or neutral conductor
| SPEC mm² | Conductor Structure | Insulation Material | Insulation Thickness (mm) | Overall Diameter (mm) |
|---|---|---|---|---|
| 1x16+1x16 | 7/1.72 | XLPE | 1.2 | 12.5 |
| 1x25+1x25 | 7/2.15 | XLPE | 1.2 | 14.9 |
| 1x35+1x35 | 7/2.54 | XLPE | 1.4 | 17.5 |
| 1x50+1x50 | 7/2.92 | XLPE | 1.4 | 20.1 |
| 1x70+1x70 | 19/2.15 | XLPE | 1.4 | 23.6 |
| 1x95+1x95 | 19/2.54 | XLPE | 1.6 | 27.6 |
| 2x16+1x16 | 7/1.72 | HDPE | 1.2 | 14.2 |
| 2x25+1x25 | 7/2.15 | HDPE | 1.2 | 16.7 |
| 2x35+1x35 | 7/2.54 | HDPE | 1.4 | 19.7 |
| 2x50+1x50 | 7/2.92 | HDPE | 1.4 | 22.5 |
| 2x70+1x70 | 19/2.15 | HDPE | 1.4 | 26.1 |
| 2x95+1x95 | 19/2.54 | HDPE | 1.6 | 30.5 |
| 3x16+1x16 | 7/1.72 | HDPE | 1.2 | 16.3 |
| 3x25+1x25 | 7/2.15 | HDPE | 1.2 | 19.1 |
| 3x35+1x35 | 7/2.54 | HDPE | 1.4 | 22.5 |
| 3x50+1x50 | 7/2.92 | HDPE | 1.4 | 25.7 |
| 3x70+1x70 | 19/2.15 | HDPE | 1.4 | 29.7 |
| 2x95+1x95 | 19/2.54 | HDPE | 1.6 | 34.6 |
-