0.6/1kV Electrical XLPE Insulated Power Cable PVC Sheathed Power Cable For Power Distribution
| Core Mark: | Number Or Color Strip | Halogen Free: | Available |
| Type: | YJV YJV22 YJV32 | Cores No: | 1-5 |
| Flame Retardant: | Available | Conductor Material: | Copper Or Al-alloy |
| Outer Sheath Color: | Black Or As Per Required | Insulation: | XLPE |
| High Light: | Electrical XLPE Insulated Power Cable,XLPE Insulated Power Cable IEC,0.6/1kV Electrical Power Cable |
||
| Rated Voltage | 0.6/1kV |
| Size | 1.5-500mm² |
| Conductor Material | Copper |
| Insulation Material | XLPE |
| Working Temperature | 90°C |
| Jacket | PVC |
| Application | Construction, Building, Photovoltaic Power, Power Distribution, Power Station |
| Type | Low Voltage, Un-armoured |
| Place of Origin | Hebei, China |
| Model Number | U1000 R2V RO2V |
| Brand Name | Minfeng |
| Cores | 1, 2, 3, 4, 5, 3+1 Cores |
| Standard | IEC 60502/XP C 32-321/NF C 32-321 |
| MOQ | 500 Meters |
U-1000 R2V RO2V Power cable 0.6/1 kV with copper conductors, XLPE insulated and PVC sheathed.
U-1000 R2V/RO2V cables can be used in all low voltage power installations. Multi-conductor cables are adapted to remote control and telecontrol installations. In case of high ambient temperature, use correction coefficient.
These cables can be fixed on cable trays, within conduits or fixed to walls. They also can be buried directly with extra mechanical protection. Cross sections 1.5, 2.5 and 4 mm² have to be of class 2 flexibility, if the cable is connected to equipment subject to vibration.
- Conductors: Copper, class 2 according to EN 60228
- Insulation: XLPE compound
- Bedding: Extruded elastomere or plastomere compound
- Sheath: PVC compound
- Identification of cores HD 308 S2:
- 2x - brown and blue
- 3x - brown, black and blue (S=1.5/2.5 mm²)
- 3x - brown, black and gray (S≥4 mm²)
- 3G - brown, blue and yellow/green
- 4x - brown, black, gray, blue
- 4G - brown, black, gray, yellow/green
- 5G - brown, black, gray, blue, yellow/green
| Standards | NF C 32-321 C32-321/A1; IEC 60502-1 NF EN 60332-1-2; NF C 15-100 |
| Nominal voltage U0/U | 0.6/1 kV |
| Test voltage (50 Hz) | 4 kV |
| Maximum voltage Um | 1.2 kV |
| Maximum operating temperature | +90°C |
-
AThe export team provided real-time tracking and handled all the customs documentation flawlessly. A very smooth procurement experience.
-
IThe custom branding and color-coding on our recent order were executed perfectly. It’s great to work with a team that follows branding guidelines so strictly.
-
ETheir engineering team was extremely helpful in customizing the shielding for our specific industrial interference requirements.