logo

450/750V 4x90mm2 Flame Retardant Rubber Sheathed Flexible Copper Cable for Industrial Applications

Basic Properties
Place of Origin: Hebei, China
Brand Name: Minfeng
Certification: ISO,CE,IEC,TUV,KEMA
Model Number: rubber cable
Trading Properties
Minimum Order Quantity: 100
Price: 0.1-5
Payment Terms: L/C,T/T
Supply Ability: 100KM/Week
Specifications
Core Mark: Number Or Color Strip Halogen Free: Available
Type: YJV YJV22 YJV32 Cores No: 1-5
Flame Retardant: Available Conductor Material: Copper Or Al-alloy
Outer Sheath Color: Black Or As Per Required Insulation: XLPE
High Light:

450V rubber sheathed copper cable

,

750V flexible electrical cable

,

4x90mm2 H07RN power cable

Product Description
450 750v 4x90mm² H07rn Rubber Sheathed Copper Flexible Cable
General Rubber Sheathed Flexible Cable
Standard: GB 5013-1997; Flame retardant (VDE 0482, EN 50265-2-1 and IEC 60332-1)
Insulation: Nitrile-Butadiene-PVC or Rubber Material or EPR, EPDM
Sheath: Nitrile-Butadiene-PVC or Rubber Material or CSP, CPE
Rated Voltage (U0/U): 300/500V; 450/750V
Conductor: Flexible Bare annealed copper wire or Tinned Copper wire
Color: Brown, gray, black, orange, red or yellow-blue, yellow-green
No. of Core: 1, 2, 3, 4, 5, 3+1
Nominal Sectional Area (mm²): 0.3~0.5, 0.75~6, 1.5~6, 1.5~400, 2, 3, 4, 5, 1~95, 1~150, 1~25, 1.5~150
Max. Permissible Operating Temperature: 60℃
Ambient Temperature of Installation: YC type: -40℃; YCW type: >-15℃
Cable Bending Radius: Not less than 5 times the outer diameter of the cable
Application: The product will be applied to drive devices, household electric instruments, all kinds of portable electrical equipment and electromotive tools at AC rated voltage U/U up to and including 450/750V
Cable Types and Specifications
Name Model Usage Feature
Light weight rubber cable YQ, YQW Household appliances, small electric equipment Soft, light and good bending performance; YQW has weather resistance and certain oil resistance
Medium-sized rubber cable YZ, YZW Industry, widely used in agricultural electrification YZW has weather resistance and certain oil resistance
Heavy rubber cable YC, YCW Used in port machinery, searchlights, large-scale water conservancy irrigation and drainage stations Has good versatility, complete series specifications, good performance and stability; YCW has weather resistance and certain oil resistance
Waterproof rubber cable JHS, JHSB Diving motor Good bending performance, can withstand frequent movement
450/750V 4x90mm2 Flame Retardant Rubber Sheathed Flexible Copper Cable for Industrial Applications 0 450/750V 4x90mm2 Flame Retardant Rubber Sheathed Flexible Copper Cable for Industrial Applications 1
Technical Specifications
Nominal section area (mm²) No./diameter of stranding (mm) Nominal sheath thickness (mm) Overall diameter (mm) Max. conductor resistance at 20℃ (Ω/km)
Min. Max Without tinned With tinned
10 322/0.20 1.8 7.5 9.7 1.91 1.95
16 513/0.20 2 9.2 11.5 1.16 1.19
25 798/0.20 2 10.5 13 0.758 0.78
35 1121/0.20 2 11.5 14.5 0.536 0.552
50 1596/0.20 2.2 13.5 17 0.379 0.39
70 2214/0.20 2.4 15 19.5 0.268 0.276
95 2297/0.20 2.6 17 22 0.198 0.204
120 1702/0.30 2.8 19 24 0.161 0.164
150 2135/0.30 3 21 27 0.129 0.132
185 1443/0.40 3.2 22 29 0.106 0.108
240 1908/0.40 3.8 25 35 0.0801 0.0817
Additional Size Specifications
Size Strands No. Insulation thickness
0.5mm² 16/0.2mm 0.6mm
0.75mm² 24/0.20mm 0.6mm
1.0mm² 32/0.20mm 0.6mm
1.5mm² 48/0.20mm 0.7mm
2.5mm² 49/0.25mm 0.8mm
4mm² 56/0.30mm 0.8mm
6mm² 84/0.30mm 0.8mm
10mm² 84/0.39mm 1.0mm
16mm² 133/0.39mm 1.0mm
Attention: We can provide more information than above data, if needed. The above are just some examples.
450/750V 4x90mm2 Flame Retardant Rubber Sheathed Flexible Copper Cable for Industrial Applications 2 450/750V 4x90mm2 Flame Retardant Rubber Sheathed Flexible Copper Cable for Industrial Applications 3
Welding Cable
Core Operating Temperature: No more than 65°C
Type: YH (Natural rubber sheathed for Welding Cable), YHF (Chloroprene Rubber or Other Synthetic sheathed Welding Cable)
Application: This product suitable for welding machines with voltage to the ground not more than DC 200V and pulsating current value of 400V
Welding Cable Technical Parameters
Nominal section area (mm²) No./diameter of stranding (mm) Nominal sheath thickness (mm) Overall diameter (mm) Max. conductor resistance at 20℃ (Ω/km) Reference Weight
Min. Max Without tinned With tinned YH YHF
10 322/0.20 1.8 7.5 9.7 1.91 1.95 146 153.51
16 513/0.20 2 9.2 11.5 1.16 1.19 218.9 230.44
25 798/0.20 2 10.5 13 0.758 0.78 316.6 331.15
35 1121/0.20 2 11.5 14.5 0.536 0.552 426 439.87
50 1596/0.20 2.2 13.5 17 0.379 0.39 592.47 610.55
70 2214/0.20 2.4 15 19.5 0.268 0.276 790 817.52
95 2297/0.20 2.6 17 22 0.198 0.204 1066.17 1102.97
120 1702/0.30 2.8 19 24 0.161 0.164 1348.25 1392.55
150 2135/0.30 3 21 27 0.129 0.132 1678.5 1698.72
185 1443/0.40 3.2 22 29 0.106 0.108 1983.8 2020.74
240 1908/0.40 3.8 25 35 0.0801 0.0817 / /
450/750V 4x90mm2 Flame Retardant Rubber Sheathed Flexible Copper Cable for Industrial Applications 4 450/750V 4x90mm2 Flame Retardant Rubber Sheathed Flexible Copper Cable for Industrial Applications 5
Mining Cable
Power Frequency Rated Voltage U/U: 0.38/0.66kV, 0.66/1.14kV, 1.9/3.3kV
Max. Permissible Operating Temperature: 65℃ for 0.38/0.66kV; 0.66/1.14kV and 90°C for 1.9/3.3kV
Min. Permissible Operating Ambient Temperature: -35℃
Bending Radius of Cable: Shall not be 6 times less than cable OD
Application: Used for source connection for coal cutter and analogous equipment at rated voltage up to and including 1.9/3.3kV
Mining Cable Types
Type Name Application
UC / MC Rubber sheathed flexible cable for mines cable for coal-cutting mining 0.38/0.66kV Driller connection under the mine shaft
UCP / MCP Screened Rubber-jacketed flexible cable for coal-cutting machine 0.38/0.66kV, 0.66/1.14kV, 1.9/3.3kV Driller connection under the mine shaft
UY / MY Rubber sheathed, movable and flexible cable for mines 0.38/0.66kV Connecting various coal cutters and similar equipment under the mine shaft
UYP / MYP Screened, Rubber sheathed, movable and flexible cable for mines 0.38/0.66kV, 0.66/1.14kV Connecting various coal cutters and similar equipment under the mine shaft
UYQ / MYQ Rubber sheathed light-duty flexible cables for mines 0.3/0.5kV Connecting various coal cutters and similar equipment under the mine shaft
UZ / MZ Electric drill Rubber cables for mines 0.3/0.5kV Power connection of various movable coal cutters under the mine shaft
UZP / MZP Electric drill shielded Rubber cables for mines 0.3/0.5kV Power connection of various movable coal cutters under the mine shaft
450/750V 4x90mm2 Flame Retardant Rubber Sheathed Flexible Copper Cable for Industrial Applications 6 450/750V 4x90mm2 Flame Retardant Rubber Sheathed Flexible Copper Cable for Industrial Applications 7
Waterproof Rubber Sheathed Cable
Model: JHS; JHSB
Rated Voltage: 450/750V; 300/500V and below diving equipment
No. of Core: 1, 3, 4, 3+1
Nominal Sectional Area (mm²): 1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70
Long-term Allowable Operating Temperature: No more than 65°C (No more than 85°C for submersible pump power transmission)
Features
  • Good electrical insulation performance under long-term water immersion and large water pressure
  • Excellent bending performance and can withstand frequent movement
  • High-density rubber selected with waterproof function
Application: Waterproof rubber sheathed cable for power transmission on diving equipment with AC voltage of 500V and below. Suitable for processing equipment such as submersible pumps, coal mines, underwater operations, underwater landscape lights, etc.
450/750V 4x90mm2 Flame Retardant Rubber Sheathed Flexible Copper Cable for Industrial Applications 8 450/750V 4x90mm2 Flame Retardant Rubber Sheathed Flexible Copper Cable for Industrial Applications 9
Silicone Rubber Cable
Executive Standard: GB12666-90 for flame retardant and fire resistance test
AC Rated Voltage: U0/U 0.6/1KV; U0/U 450/750V (Silicone Rubber Control Cable)
Maximum Working Temperature: 180℃
Minimum Ambient Temperature: Silicone rubber sheath: fixed laying -60℃, non-fixed laying -20℃
Cable Installation and Laying Temperature: Not lower than -25℃ (Not lower than -20℃ for Silicone Rubber Control Cable)
Allowable Bending Radius: Minimum cable is 10 times the outer diameter of the cable; Unarmoured cable minimum 6 times the outer diameter of the cable (Silicone Rubber Control Cable)
Features
Heat-resistant radiation, cold resistance, high temperature resistance, voltage resistance, acid and alkali resistance and corrosive gas, waterproof, etc.
Advantages
  • Good thermal stability and stable electrical performance in high temperature, high and low temperature, high cold and corrosive environments
  • Soft structure, convenient laying, outstanding anti-aging performance and long service life
Application
  • Used for power transmission lines for fixed laying or connecting cables for mobile electrical appliances with AC rated voltage of 0.6/1KV and below
  • Silicone rubber control cable is suitable for connecting wire or signal transmission of electrical instruments for mobile or fixed laying with AC rated voltage of 450/750V and below
  • Widely used in metallurgy, electric power, petrochemical, electronics, automobile manufacturing and other industries
Silicone Rubber Cable Models
Silicone Rubber Power Cable Silicone Rubber Control Cable
Model Name Model Name
YGC Silicone rubber insulated sheathed power cable KGG Silicone Rubber Insulated and Sheathed Control Cables
YGCR Silicone rubber insulated sheathed mobile power flexible cable KGGR Silicone Rubber Insulated and Sheathed Control Flexible Cable
YGCP Silicone rubber insulated sheathed copper braided shielded power cable KGGP Silicone rubber insulated and sheathed copper wire braided shielded control cable
YGC22 Silicone rubber insulated sheathed steel tape armored power cable KGGRP Silicone rubber insulated and sheathed copper wire braided shielded control flexible cable
JGG Silicone Rubber Insulation Sheath Installation Wire KGGRP1 Silicone rubber insulated and sheathed tinned braided shielded control flexible cable
JGGR Silicone rubber insulating sheath mobile installation cord KFG Fluoroplastic insulated and silicone rubber sheathed control cable
JGGP Silicone rubber insulated sheathed copper braided shielded installation wire
JHXG Silicone rubber insulated motor lead wire
Note: ZR is added before the model of flame retardant silicone rubber cable, and the copper wire in the conductor core can be tinned
450/750V 4x90mm2 Flame Retardant Rubber Sheathed Flexible Copper Cable for Industrial Applications 10 450/750V 4x90mm2 Flame Retardant Rubber Sheathed Flexible Copper Cable for Industrial Applications 11 450/750V 4x90mm2 Flame Retardant Rubber Sheathed Flexible Copper Cable for Industrial Applications 12
Overall Rating
5.0
★★★★★
★★★★★
Based on 50 reviews recently
5 star
100%
4 star
0
3 star
0
2 star
0
1 star
0
All Reviews
  • S
    Savvon Maksymchuk
    Ukraine Nov 10.2023
    ★★★★★
    ★★★★★
    We’ve been ordering from this factory for three years. The consistency between batches is incredible; the quality of the first shipment matches the hundredth
  • I
    Ima Ima
    Pakistan Apr 15.2022
    ★★★★★
    ★★★★★
    The custom branding and color-coding on our recent order were executed perfectly. It’s great to work with a team that follows branding guidelines so strictly.
  • E
    Eglis Sirithatthamrong
    Thailand Nov 25.2021
    ★★★★★
    ★★★★★
    Their engineering team was extremely helpful in customizing the shielding for our specific industrial interference requirements.