Overhead ACSR 477 KCMIL/MCM Bare Conductor With High Tensile Strength ASTM-B232
| Core Mark: | Number Or Color Strip | Halogen Free: | Available |
| Type: | YJV YJV22 YJV32 | Cores No: | 1-5 |
| Flame Retardant: | Available | Conductor Material: | Copper Or Al-alloy |
| Outer Sheath Color: | Black Or As Per Required | Insulation: | XLPE |
| High Light: | KCMIL Bare Conductor,Bare Conductor ASTM-B232,477 MCM Bare Conductor |
||
Producing and providing products according to Chinese standard GB/T3954-2001, and consulting and following the American standard ASTM B233:1997 and German DIN standard EN 17152:1997.
Note: When the mechanical function and electrical function of products are qualified, the component of chemical elements may not be the total checking date.
| Name of Element | Si | Fe | Cu | V+Ti+Mn+Cr | Other | Al |
|---|---|---|---|---|---|---|
| Percentage % | ≤0.11 | 0.25 | 0.01 | 0.02 | 0.03 | ≥99.61 |
- Should be neat and well-distributed in dimension on surface of aluminum rod
- Aluminum rod surface should be clean and free from flaws, wrinkles, wrong round, crackle, mess kink and other shortcomings that affect usage
- Permissible: slightly mechanical rub speck, pit, losing leather or fing border
Conductor (AAC and ACSR) have been widely used in power transmission lines with various voltage levels because they have such good characteristics as simple structure, convenient installation and maintenance, low cost, and large transmission capacity. They are also suitable for laying across rivers, valleys, and places with special geographical features.
- High tensile strength
- Better sag properties
- Economic design
- Best suited for transmission lines with long spans
- Ambient temperature: Above -20°C
- Working temperature: Not exceed 80°C
- Laying bending radius: Not less than 30 times the cable's outer diameter
- ASTM-B232 Standard specification for Concentric-Lay-Stranded Aluminum 1350 conductors
- BS215-2 Aluminium conductors steel-reinforced, for overhead power transmission
- DIN48204 Steel reinforced aluminum stranded conductors
- IEC209 Aluminum stranded conductor steel reinforced
- Customized type available
- Good electrical conductivity
- Sufficient mechanical strength
- High tensile strength
- Tower distance can be enlarged
- No power loss
- High current carrying capacity
- High fatigue strength
- More corrosion resistant
- Conductor: AL1350 pure aluminum
- Steel core: G1A or G2A steel wire
- Zinc coating steel wire
- Aluminum stranded wire: consists of 7, 19, 37, 91, 127 concentric strands
- Aluminum alloy: heat-treated magnesium silicate high-strength 6201T81 aluminum alloy
| Code Number | Calculated Area mm² | Stranding and Wire Diameter | Overall Diameter mm | Linear Mass Kg/km | Calculated Breaking load daN | Max. D.C. Resistance at 20°C Ω/km |
|---|---|---|---|---|---|---|
| 16 | 15.89 | 7/1.70 | 5.1 | 44 | 290 | 1.8018 |
| 25 | 24.25 | 7/2.10 | 6.3 | 67 | 425 | 1.1808 |
| 35 | 34.36 | 7/2.50 | 7.5 | 94 | 585 | 1.8332 |
| 50 | 49.48 | 7/3.00 | 9 | 135 | 810 | 0.5786 |
| 50 | 48.36 | 19/1.80 | 9 | 133 | 860 | 0.595 |
| 70 | 65.82 | 19/2.10 | 10.5 | 181 | 1150 | 0.4371 |
| 95 | 95.27 | 15/2.50 | 12.5 | 256 | 1595 | 0.3084 |
| 120 | 117 | 19/2.80 | 14 | 322 | 1910 | 0.2459 |
| 150 | 147.1 | 37/2.25 | 15.2 | 406 | 2570 | 0.196 |
| 185 | 181.6 | 37/2.50 | 17.5 | 501 | 3105 | 0.1587 |
| 240 | 242.54 | 61/2.25 | 20.2 | 670 | 4015 | 0.1191 |
| 300 | 299.43 | 61/2.50 | 22.5 | 827 | 4850 | 0.0965 |
| 400 | 400.14 | 61/2.89 | 26 | 1105 | 6190 | 0.07221 |
| 500 | 499.83 | 61/3.23 | 29.1 | 1381 | 7600 | 0.05781 |
| 625 | 626.2 | 91/2.96 | 32.6 | 1733 | 9690 | 0.04625 |
| 800 | 802.1 | 91/3.35 | 36.8 | 2219 | 12055 | 0.03611 |
| 1000 | 999.71 | 91/3.74 | 41.1 | 2766 | 14845 | 0.02897 |
-