26/45(52) kV XLPE Insulated Power Cable with Aluminium Conductor and PE Outer Sheath for Industrial Use

기본 특성
원산지: 중국 허베이
브랜드 이름: Minfeng
인증: ISO,CE,IEC,TUV,KEMA
모델 번호: AXLJ-TTCL TSLF
부동산 거래
최소 주문 수량: 100m
가격: 0.1-5
지불 조건: 신용장, 티/티
공급 능력: 주당 100km
명세서
Insulation: XLPE 절연 Sample: 무료
Cable Type: XLPE 절연 전원 케이블 Max operating temperature: 90°C
Voltage rating: 26/45(52)kV Cable Jacket: 체육
Standard compliance: IEC 60840 Application: 산업용
Model: AXLJ-TTCL TSLF
제품 설명
AXLJ-TTCL TSLF 26/45(52) KV Cable Aluminium Conductor XLPE Insulation PE Outer Sheath
Product Overview
AXLJ-TTCL TSLF Medium Voltage Cable - Industrial Power Cable
AXLJ-TTCL TSLF 26/45(52) KV Cable Aluminium Conductor XLPE Insulation PE Outer Sheath
Rated Voltage 26/45(52) kV
Size 240-800mm²
Conductor Material Aluminum
Insulation Material XLPE
Working Temperature 90°C
Jacket PE
Application Industrial
Type Medium Voltage
Place of Origin Hebei, China
Model Number AXLJ-TTCL TSLF
Brand Name Minfeng
Standard IEC 60840
Application & Description
Power cable with round, stranded and compacted aluminium conductor. Cable is radially and longitudinally water-sealed. The screen is made up of circular copper wires and aluminium laminate. The aluminium laminate is included in screen cross-section. The outer sheath has a conductive layer that greatly extends the possibilities to do a sheath testing before, during and after installation. For fixed outdoor installations, suitable for ploughing down.
Cable Construction
Cable shape Round
Conductor Stranded, round, compacted copper acc. to IEC 60228 class 2, longitudinally water sealed
Insulation XLPE, nom thickness 9,0 mm
Conductor screen Semiconducting copolymer compound
Insulation screen Semiconducting copolymer compound
Longitudinal water tightness Semiconducting water blocking tape
Shielding Annealed copper wires in contact with aluminum tape
Radial water blocking Aluminium-PE laminate, bonded to sheath
Ripcord Aramid
Outer sheath Black PE
Semi-conducting layer in outer sheath Yes (facilitates sheath testing)
Temperature Specifications
  • Max operating temperature: 90°C
  • Max short circuit temperature: 250°C
  • Min temperature at installation: -20°C (below 0°C special precautions are recommended)
Technical Specification
AXLJ-TTCL TSLF 26/45(52) KV Cable Aluminium Conductor XLPE Insulation PE Outer Sheath
AXLJ-TTCL TSLF Cable Technical Specifications and Dimensions