26/45(52) kV XLPE Insulated Power Cable with Aluminium Conductor and PE Outer Sheath for Industrial Use
基本プロパティ
原産地:
河北省、中国
ブランド名:
Minfeng
認定:
ISO,CE,IEC,TUV,KEMA
モデル番号:
AXLJ-TTCL TSLF
取引物件
最低注文数量:
100メートル
価格:
0.1-5
支払い条件:
LC、T/T
補給能力:
100km/週
仕様
| Insulation: | XLPE絶縁 | Sample: | 無料 |
| Cable Type: | XLPE絶縁電源ケーブル | Max operating temperature: | 90 °C |
| Voltage rating: | 26/45(52)kV | Cable Jacket: | PE |
| Standard compliance: | IEC 60840 | Application: | 産業用 |
| Model: | AXLJ-TTCL TSLF |
製品の説明
AXLJ-TTCL TSLF 26/45(52) KV Cable Aluminium Conductor XLPE Insulation PE Outer Sheath
Product Overview
AXLJ-TTCL TSLF 26/45(52) KV Cable Aluminium Conductor XLPE Insulation PE Outer Sheath
Rated Voltage
26/45(52) kV
Size
240-800mm²
Conductor Material
Aluminum
Insulation Material
XLPE
Working Temperature
90°C
Jacket
PE
Application
Industrial
Type
Medium Voltage
Place of Origin
Hebei, China
Model Number
AXLJ-TTCL TSLF
Brand Name
Minfeng
Standard
IEC 60840
Application & Description
Power cable with round, stranded and compacted aluminium conductor. Cable is radially and longitudinally water-sealed. The screen is made up of circular copper wires and aluminium laminate. The aluminium laminate is included in screen cross-section. The outer sheath has a conductive layer that greatly extends the possibilities to do a sheath testing before, during and after installation. For fixed outdoor installations, suitable for ploughing down.
Cable Construction
| Cable shape | Round |
| Conductor | Stranded, round, compacted copper acc. to IEC 60228 class 2, longitudinally water sealed |
| Insulation | XLPE, nom thickness 9,0 mm |
| Conductor screen | Semiconducting copolymer compound |
| Insulation screen | Semiconducting copolymer compound |
| Longitudinal water tightness | Semiconducting water blocking tape |
| Shielding | Annealed copper wires in contact with aluminum tape |
| Radial water blocking | Aluminium-PE laminate, bonded to sheath |
| Ripcord | Aramid |
| Outer sheath | Black PE |
| Semi-conducting layer in outer sheath | Yes (facilitates sheath testing) |
Temperature Specifications
- Max operating temperature: 90°C
- Max short circuit temperature: 250°C
- Min temperature at installation: -20°C (below 0°C special precautions are recommended)
Technical Specification
AXLJ-TTCL TSLF 26/45(52) KV Cable Aluminium Conductor XLPE Insulation PE Outer Sheath
総格付け
最高
100%
4つ星
0
3つ星
0
2つ星
0
星1つ
0
All Reviews
-
CWe’ve integrated these fiber optic cables into our latest data center project. The attenuation levels are remarkably low, exceeding our performance benchmarks.