logo

Kabel NA2XY IEC 60502-1 AL/XLPE/PVC 1.8/3 (3.6) kV 0.6/1kV AL/XLPE/MDPE 1.8/3kV AL/XLPE/MDPE Aluminium Conductor

Properti Dasar
Tempat Asal: Hebei, Tiongkok
Nama merek: Minfeng
Sertifikasi: ISO,CE,IEC,TUV,KEMA
Nomor Model: Kabel NA2XY AL
Properti Perdagangan
Jumlah Pesanan Minimum: 100m
Harga: 0.1-5
Ketentuan Pembayaran: L/C,T/T
Kemampuan Pasokan: 100 km/minggu
Spesifikasi
Sheath Material: PVC//MDPE Color: Hitam
Conductor: Aluminium Sample: Bebas
Model Type: Kabel NA2XY AL Voltage: 0,6/1kv 1,8/3 (3,6)kV 1,8/3kV
Deskripsi Produk

Atribut utama


Nilai Tegangan
0,6/1kv, 1,8/3,6kv
Ukuran
16-1000mm2
Bahan Konduktor
Aluminium
Bahan Isolasi
XLPE
Suhu Kerja
-35°C hingga +90°C
Jaket
PVC//MDPE
Tingkat IP
/
Aplikasi
Industri
Nilai Saat Ini
/
Jenis
Tegangan Rendah
Tempat Asal
Hebei, Tiongkok
Nomor Model
Kabel NA2XY AL
Nama Merek
Minfeng
Nama Produk
Kabel NA2XY IEC 60502-1 AL
Standar
IEC 60502-1, IEC 60228
Konduktor
Aluminium
Isolasi
XLPE
Tegangan nominal
0,6/1kv 1,8/3 (3,6)kV 1,8/3kV
Sarung
PVC//MDPE
Deskripsi Produk
Kabel NA2XY IEC 60502-1 AL/XLPE/PVC 1.8/3 (3.6) kV 0.6/1kV AL/XLPE/MDPE 1.8/3kV AL/XLPE/MDPE Aluminium Conductor

Kabel NA2XY IEC 60502-1 AL/XLPE/PVC 1.8/3 (3.6)kV 0.6/1kV AL/XLPE/MDPE 1.8/3kV AL/XLPE/MDPE Konduktor Aluminium
APLIKASIKabel daya Tegangan Rendah dan kabel tetap bantu untuk suplai energi listrik. Cocok untuk pemasangan eksternal termasuk kondisi basah dan terendam (AD8). Cocok untuk pemakaman langsung.KARAKTERISTIKPeringkat Tegangan AC: 1,8/3 (3,6)kV DC: 2,7/5,4 kV AC: 0,6/1 (1,2)kV DC: 0,9/1,8kV Kisaran Suhu Suhu Pengoperasian Konduktor Maksimum: +90ºC Suhu Konduktor Maksimum Selama SC: +250°C Radius Bending Minimum 6 x Diameter Keseluruhan Inti tunggal: 15 x Diameter Keseluruhan Multiinti: 12 x Diameter KeseluruhanKONSTRUKSIKonduktor Kelas 2 Terdampar Aluminium Polos Insulasi Konduktor Kompak Melingkar XLPE (Polietilen Tautan Silang) Selubung MDPE (Polietilen Kepadatan Menengah) PVC (Polivinil Klorida)STANDARIEC 60502-1, IEC 60228, tahan UV ISO 4892 Bebas halogen hingga IEC 60754 Tahan air hingga AD8
Spesifikasi
Kabel NA2XY IEC 60502-1 AL/XLPE/PVC 1,8/3 (3,6)kV
TIDAK. DARI INTI
SILANG NOMINAL
WILAYAH BAGIAN mm2
NOMINAL LUAR
DIAMETERmm
BERAT NOMINAL
kg/km
1
16
10.9
140
1
25
12
180
1
35
13.1
215
1
50
14.4
265
1
70
16.2
350
1
95
17.7
430
1
120
19.3
530
1
150
21.5
635
1
185
22.6
750
1
240
25.2
935
1
300
27.5
1125
1
400
30.4
1410
1
500
34.3
1775
1
630
38.4
2280
1
800
43.8
2945
1
1000
50.7
3710
Kabel NA2X2Y 1.8/3kV IEC 60502-1 AL/XLPE/MDPE
TIDAK. DARI INTI
SILANG NOMINAL
AREA BAGIAN
mm2
INSULASI NOMINAL
KETEBALAN mm
sarung nominal
KETEBALAN
mm
NOMINAL LUAR
DIAMETER
mm
NOMINAL
BERAT
kg/km
1
16
2
1.4
11.1
122
1
25
2
1.4
12.2
156
1
35
2
1.4
13.3
193
1
50
2
1.4
14.6
238
1
70
2
1.5
16.2
314
1
95
2
1.5
17.7
389
1
120
2
1.6
19.3
480
1
150
2
1.6
21.5
578
1
185
2
1.7
22.6
686
1
240
2
1.8
25.2
863
1
300
2
1.8
27.6
1053
1
400
2
1.9
30.3
1316
1
500
2.2
2
33.9
1659
1
630
2.4
2.2
38.4
2146
Kabel NA2X2Y 0,6/1kV IEC 60502-1 AL/XLPE/MDPE
TIDAK. DARI
INTI
SILANG NOMINAL
AREA BAGIAN
mm2
INSULASI NOMINAL
KETEBALAN
mm
KETEBALAN SELURUH NOMINAL
mm
NOMINAL KESELURUHAN
DIAMETER
mm
NOMINAL
BERAT
kg/km
1
16
0,7
1.4
8.5
85
1
25
0,9
1.4
10
120
1
35
0,9
1.4
11.1
155
1
50
1.0
1.4
12.6
200
1
70
1.1
1.4
14.4
275
1
95
1.1
1.5
16.1
350
1
120
1.2
1.5
17.7
440
1
150
1.4
1.6
20.3
545
1
185
1.6
1.6
21.6
655
1
240
1.7
1.7
24.4
835
1
300
1.8
1.8
27.2
1040
1
400
2.0
1.9
30.3
1320
1
500
2.2
2
33.9
1660
1
630
2.4
2.2
38.6
2160
1
800
2.6
2.3
44
2800
1
1000
2.8
2.4
49.2
3445
2
70
1.1
1.8
27.5
760
2
95
1.1
2
30.9
975
2
120
1.2
2.1
34.1
1215
2
150
1.4
2.2
39.5
1555
2
185
1.6
2.3
42.3
1860
2
240
1.7
2.5
47.9
2380
2
300
1.8
2.7
53.5
2970
2
400
2
2.9
59.7
3760
3
70
1.1
1.9
25.9
855
3
95
1.1
2
29.2
1090
3
120
1.2
2.1
32.4
1375
3
150
1.4
2.3
35.5
1690
3
185
1.6
2.4
39.5
2085
3
240
1.7
2.6
44.6
2650
3
300
1.8
2.8
49.5
3255
3
400
2
3.1
56.7
4290
4
70
1.1
2
30.2
1090
4
95
1.1
2.1
32.7
1390
4
120
1.2
2.3
36.8
1775
4
150
1.4
2.4
41.3
2190
4
185
1.6
2.6
46.3
2725
4
240
1.7
2.8
52.1
3460
4
300
1.8
3
57.7
4275
4
400
2
3.3
66.1
5660