NSSHOEU Rubber Cable with EPR Rubber Insulation 0.6/1kV Voltage Rating and Tinned Copper Conductor for Mining Industry
Grundlegende Eigenschaften
Herkunftsort:
Hebei, China
Markenbezeichnung:
Minfeng
Zertifizierung:
ISO,CE,IEC,TUV,KEMA
Modellnummer:
Gummikabel
Immobilienhandel
Mindestbestellmenge:
100
Preis:
0.1-5
Zahlungsbedingungen:
L/C, T/T
Lieferfähigkeit:
100 km/Woche
Spezifikationen
| Insulation: | EPR-Gummi | Voltage: | 0,6/1kV |
| Corporation: | Minfeng-Gruppe | Minimum Order: | 100 m |
| Application: | Industriemaschinen, Elektrowerkzeuge, Geräte | Origin: | Hebei, China |
| Conductor: | Kupfer | Free Sample: | Verfügbar |
| Standardscompliance: | VDE 0250 Teil 812 | Sheathmaterial: | Gummi |
Produkt-Beschreibung
0.6/1kV NSSHOEU NSSHOEU-O NSSHOEU-J Tinned Copper EPR CPE 4X16mm Mining Industry Rubber Cable
Heavy duty flexible rubber cable designed for mobile equipment and machines under high mechanical loads in dry, damp, and outdoor environments, including explosion hazard areas in mining, quarries, and building sites.
Product Specifications
Rated Voltage
0.6/1 kV
Conductor Material
Tinned Copper
Insulation Material
EPR Rubber
Sheath Material
CPE Rubber
Working Temperature
-40°C to 90°C
Max Short Circuit Temperature
250°C
Conductor Size Range
1.5-800mm²
Standards
VDE 0250 Part 812
Sample Availability
Available
Minimum Order Quantity
500m
Warranty
1 Year
Applications
Connection of mobile equipment and machines under very high mechanical loads in dry and damp areas, outdoors and in explosion hazard areas, particularly in mining and industry, quarries and building sites.
Design Features
- Conductor: Copper, tinned, finely stranded (class 5) in accordance with DIN VDE 0295/IEC 60228
- Insulation: EPR, Compound type: 3GI3 in accordance with DIN VDE 0207
- Inner sheath: EPR, Compound type: GM1B in accordance with DIN VDE 0207 (not for single-core cables)
- Outer sheath: Rubber compound, synthetic elastomer compound e.g. CPE, Compound: 5GM5 in accordance with DIN VDE 0207
- Color: Yellow
Thermal Parameters
- Rated voltage: 0.6/1 kV (600/1000V)
- Max. permissible operating voltage AC: 0.7/1.2 kV
- Max. permissible operating voltage DC: 0.9/1.8 kV
- AC test voltage: 3 kV
- Duration of AC test voltage: 5 min
- Max. permissible temperature at conductor: 90°C
- Max. short circuit temperature of the conductor: 250°C
- Max. permissible water temperature: 40°C (for higher temperatures a life time reduction is expected)
Product Images
Technical Specifications
NSSHOEU-O Specifications
| Number of Cores × Cross Section | Minimum Overall Diameter (mm) | Maximum Overall Diameter (mm) | Nominal Weight (kg/km) |
|---|---|---|---|
| 1×16 | 11 | 13.5 | 260 |
| 1×25 | 13 | 16 | 390 |
| 1×35 | 14 | 17 | 500 |
| 1×50 | 16 | 19 | 680 |
| 1×70 | 18 | 21 | 900 |
| 1×95 | 20 | 24 | 1150 |
| 1×120 | 23 | 27 | 1440 |
| 1×150 | 24 | 28 | 1750 |
| 1×185 | 28 | 31 | 2300 |
| 1×240 | 32 | 36 | 3000 |
| 2×1.5 | 11 | 14 | 210 |
| 3×2.5 | 13 | 16 | 300 |
NSSHOEU-J Specifications
| Number of Cores × Cross Section | Minimum Overall Diameter (mm) | Maximum Overall Diameter (mm) | Nominal Weight (kg/km) |
|---|---|---|---|
| 3×1.5 | 12 | 15 | 240 |
| 3×70/35 | 46 | 51 | 4450 |
| 3×95/50 | 54 | 59 | 5870 |
| 3×120/70 | 59 | 64 | 7340 |
| 4×1.5 | 13 | 16 | 280 |
| 4×2.5 | 15 | 18 | 400 |
| 4×4 | 17 | 20 | 510 |
| 4×6 | 18 | 21 | 630 |
| 4×10 | 22 | 26 | 950 |
| 4×16 | 28 | 32 | 1430 |
| 4×25 | 33 | 37 | 2100 |
| 4×35 | 36 | 40 | 2650 |
| 4×50 | 42 | 47 | 3660 |
| 5×1.5 | 13 | 16 | 320 |
| 5×2.5 | 16 | 19 | 470 |
| 5×4 | 18 | 21 | 600 |
| 5×6 | 20 | 24 | 780 |
| 5×10 | 24 | 28 | 1130 |
| 5×16 | 29 | 34 | 1720 |
| 5×25 | 35 | 39 | 2470 |
| 6×2.5 | 13 | 16 | 300 |
| 7×1.5 | 16 | 19 | 470 |
| 7×2.5 | 18 | 21 | 600 |
| 10×1.5 | 19 | 22 | 570 |
| 10×2.5 | 21 | 25 | 790 |
| 12×2.5 | 22 | 26 | 860 |
| 18×2.5 | 28 | 32 | 1240 |