0.6/1kV Offshore Cable with Halogen Free EPR Insulation and Galvanized Steel Wire Braid Armour for Marine Applications

Temel Özellikler
Menşe Yeri: Hebei, Çin
Marka Adı: Minfeng
Sertifikasyon: ISO,CE,IEC,TUV,KEMA
Model Numarası: TCu/MGT/EPR
Ticaret Mülkleri
Minimum Sipariş Miktarı: 100m
Fiyat: 0.1-5
Ödeme Koşulları: L/C,T/T
Tedarik Yeteneği: 100km/hafta
Özellikler
Voltage Rate: 0.6/1kv Conductor: Kalaylı Bakır
Sheath Material: Halojen içermeyen ısıya dayanıklı Type: 0,6/1kV TCu/MGT/EPR/ZH/GSWB/ZH SW4 Açık Deniz Kablosu
Packing: ahşap davul, çelik-ahşap davul Insulation: Halojensiz EPR
Ürün Tanımı
0.6/1kV TCu/MGT/EPR/ZH/GSWB/ZH SW4 Offshore Cable 150/250V TCu/MGT/EPR/IS/CS/ZH/GSWB/ZH Offshore Instrument Control Cable
Product Overview

Fire resistant cables for fixed wiring in ships and on mobile and fixed offshore units.

Rated Voltage 0.6/1KV, 150/250V
Size Range 1.5-250mm²
Conductor Material Tinned Copper
Insulation Material Halogen Free EPR
Working Temperature -20°C to +70°C
Jacket Halogen Free Heat Resistant
Application Industrial
Type Low Voltage
Standards & Certifications
  • BS 7917, IEC/EN 60331-21
  • Flame Retardant according to IEC/EN 60332-3-22, IEC/EN 60332-1-2
  • Halogen Free according to: IEC/EN 60754-1/2
TCu/MGT/EPR/ZH/GSWB/ZH 0.6/1kV SW4 Cable
TCu/MGT/EPR/ZH/GSWB/ZH 0.6/1kV SW4 Offshore Cable construction diagram
Characteristics
  • Voltage Rating (Uo/U): 0.6/1kV
  • Temperature Rating: -40°C to +90°C
  • Minimum Bending Radius: Up to 25mm²: 4 x overall diameter; 25mm² and above: 6 x overall diameter
Construction
  • Conductor: 1.5mm²: Class 5 flexible tinned copper conductor; 2.5mm²: Class 2 stranded tinned copper conductor
  • Separator: Mica glass tape
  • Insulation: Halogen free EPR (Ethylene Propylene Rubber) Type GP4
  • Bedding: Halogen free elastomer EPR (Ethylene Propylene Rubber) Type SB 1
  • Armour: GSWB (Galvanized Steel Wire Braid)
  • Sheath: Halogen free heat resistant, oil resisting and flame retardant elastomer compound Type SW4
TCu/MGT/EPR/IS/ZH/GSWB/ZH 150/250V Cable
TCu/MGT/EPR/IS/ZH/GSWB/ZH 150/250V Cable construction diagram
Characteristics
  • Voltage Rating Uo/U: 150/250V
  • Test Voltage: 1.5kV
  • Temperature Rating: -40°C to +90°C
  • Minimum Bending Radius: 10 x overall diameter
Construction
  • Conductor: 0.75mm² to 1.5mm²: Class 5 flexible tinned copper conductor; 2.5mm² and above: Class 2 stranded tinned copper conductor
  • Separator: Mica glass tape
  • Insulation: Halogen free EPR (Ethylene Propylene Rubber)
  • Screen: Individual aluminium polyester tape
  • Bedding: Halogen free elastomer EPR (Ethylene Propylene Rubber)
  • Armour: GSWB (Galvanized Steel Wire Braid)
  • Sheath: Halogen free heat resistant, oil resisting and flame retardant elastomer compound
TCu/MGT/EPR/CS/ZH/GSWB/ZH 150/250V Cable
TCu/MGT/EPR/CS/ZH/GSWB/ZH 150/250V Cable construction diagram
Characteristics
  • Voltage Rating Uo/U: 150/250V
  • Temperature Rating: -40°C to +90°C
  • Minimum Bending Radius: 6 x overall diameter
Construction
  • Conductor: Class 5 flexible tinned copper conductor
  • Separator: Mica glass tape
  • Insulation: Halogen free EPR (Ethylene Propylene Rubber)
  • Drain Wire: Tinned copper
  • Screen: Collective aluminium polyester tape
  • Bedding: Halogen free elastomer EPR (Ethylene Propylene Rubber)
  • Armour: GSWB (Galvanized Steel Wire Braid)
  • Sheath: Halogen free heat resistant, oil resisting and flame retardant elastomer compound
Additional Specifications
Offshore cable technical specifications diagram Offshore cable installation guidelines Offshore cable performance characteristics
Genel derecelendirme
5.0
★★★★★
★★★★★
Son 50 incelemeye göre
5 YILDIZ
100%
4 yıldız
0
3 Yıldız
0
2 yıldız
0
1 yıldız
0
All Reviews
  • G
    Grev lithium
    India Apr 26.2024
    ★★★★★
    ★★★★★
    The LSZH (Low Smoke Zero Halogen) properties of these cables are exactly as advertised. They performed exceptionally well during our fire safety compliance audit.
  • I
    IBRAHIM CALVA
    Equatorial Guinea Mar 8.2020
    ★★★★★
    ★★★★★
    Our field technicians have specifically requested this brand because the cable is easy to strip and pull through conduits, saving us significant man-hours on-site.