logo

0.6/1kV Offshore Cable with Halogen Free EPR Insulation and Galvanized Steel Wire Braid Armour for Marine Applications

Propiedades básicas
Lugar de origen: Hebei, China
Nombre de la Marca: Minfeng
Certificación: ISO,CE,IEC,TUV,KEMA
Número de modelo: Cable costa afuera TCu/MGT/EPR/ZH/GSWB/ZH SW4
Propiedades comerciales
Cantidad mínima de pedido: 100m
Precio: 0.1-5
Condiciones de pago: LC, T/T
Capacidad de suministro: 100 km/semana
Presupuesto
Insulation: EPR libre de halógenos Rated Voltage: 0.6/1KV
Sample: Disponible Cable Type: Cable costa afuera
Standard Compliance: BS 7917, IEC/EN 60331-21 Sheath material: Sección 4
Cable Mark: impresión o estampado de tinta
Descripción de producto
0.6/1kV TCu/MGT/EPR/ZH/GSWB/ZH SW4 Offshore Cable 150/250V TCu/MGT/EPR/IS/CS/ZH/GSWB/ZH Offshore Instrument Control Cable
Product Overview

Fire resistant cables for fixed wiring in ships and on mobile and fixed offshore units. Compliant with international standards for marine and offshore applications.

Key Specifications
Rated Voltage 0.6/1kV, 150/250V
Conductor Size 1.5-250mm²
Conductor Material Tinned Copper
Insulation Material Halogen Free EPR
Working Temperature -20°C to +70°C
Jacket Halogen Free Heat Resistant
Application Industrial - Marine & Offshore
Standards BS 7917, IEC/EN 60331-21
TCu/MGT/EPR/ZH/GSWB/ZH 0.6/1kV SW4 Cable
TCu/MGT/EPR/ZH/GSWB/ZH 0.6/1kV SW4 Offshore Cable construction diagram
Characteristics
Voltage Rating (Uo/U): 0.6/1kV
Temperature Rating: -40°C to +90°C
Minimum Bending Radius: Up to 25mm²: 4 x overall diameter; 25mm² and above: 6 x overall diameter
Construction
  • Conductor: 1.5mm²: Class 5 flexible tinned copper conductor; 2.5mm²: Class 2 stranded tinned copper conductor
  • Separator: Mica glass tape
  • Insulation: Halogen free EPR (Ethylene Propylene Rubber) Type GP4
  • Bedding: Halogen free elastomer EPR (Ethylene Propylene Rubber) Type SB 1
  • Armour: GSWB (Galvanized Steel Wire Braid)
  • Sheath: Halogen free heat resistant, oil resisting and flame retardant elastomer compound Type SW4
TCu/MGT/EPR/IS/ZH/GSWB/ZH 150/250V Cable
TCu/MGT/EPR/IS/ZH/GSWB/ZH 150/250V Cable construction diagram
Characteristics
Voltage Rating (Uo/U): 150/250V
Test Voltage: 1.5kV
Temperature Rating: -40°C to +90°C
Minimum Bending Radius: 10 x overall diameter
Construction
  • Conductor: 0.75mm² to 1.5mm²: Class 5 flexible tinned copper conductor; 2.5mm² and above: Class 2 stranded tinned copper conductor
  • Separator: Mica glass tape
  • Insulation: Halogen free EPR (Ethylene Propylene Rubber)
  • Screen: Individual aluminium polyester tape
  • Bedding: Halogen free elastomer EPR (Ethylene Propylene Rubber)
  • Armour: GSWB (Galvanized Steel Wire Braid)
  • Sheath: Halogen free heat resistant, oil resisting and flame retardant elastomer compound
TCu/MGT/EPR/CS/ZH/GSWB/ZH 150/250V Cable
TCu/MGT/EPR/CS/ZH/GSWB/ZH 150/250V Cable construction diagram
Characteristics
Voltage Rating (Uo/U): 150/250V
Temperature Rating: -40°C to +90°C
Minimum Bending Radius: 6 x overall diameter
Construction
  • Conductor: Class 5 flexible tinned copper conductor
  • Separator: Mica glass tape
  • Insulation: Halogen free EPR (Ethylene Propylene Rubber)
  • Drain Wire: Tinned copper
  • Screen: Collective aluminium polyester tape
  • Bedding: Halogen free elastomer EPR (Ethylene Propylene Rubber)
  • Armour: GSWB (Galvanized Steel Wire Braid)
  • Sheath: Halogen free heat resistant, oil resisting and flame retardant elastomer compound
Additional Specifications
Offshore cable technical specifications diagram Offshore cable installation guidelines Offshore cable application examples
Compliance Standards
  • BS 7917
  • IEC/EN 60331-21
  • Flame Retardant according to IEC/EN 60332-3-22, IEC/EN 60332-1-2
  • Halogen Free according to: IEC/EN 60754-1/2
Calificación general
5.0
★★★★★
★★★★★
Basado en 50 reseñas recientes
de cinco estrellas
100%
4 estrellas
0
3 estrellas
0
2 estrellas
0
1 estrella
0
All Reviews
  • G
    Grev lithium
    India Apr 26.2024
    ★★★★★
    ★★★★★
    The LSZH (Low Smoke Zero Halogen) properties of these cables are exactly as advertised. They performed exceptionally well during our fire safety compliance audit.
  • I
    IBRAHIM CALVA
    Equatorial Guinea Mar 8.2020
    ★★★★★
    ★★★★★