Kabel ACSR Konduktor Aluminium Telanjang Tegangan Rendah Untuk Aplikasi Udara
| Exoprt Experience: | Amerika Selatan, Afrika, Timur Tengah dll | Conductor Shape: | Bundar |
| Free Sample: | Ya | Insulating Material: | Telanjang |
| Cores No: | 1-36 | Application: | Transmisi daya |
| Material Of Conductor: | Aluminium | ||
| High Light: | Konduktor Aluminium Telanjang,Konduktor Telanjang Di Atas,Konduktor Kabel ACSR |
||
| Bahan Konduktor | Kabel ACSR |
|---|---|
| Bahan Isolasi | Tidak ada bahan isolasi |
| Selubung | Tidak ada selubung |
| Aplikasi | Udara |
| Tipe | Tegangan Rendah |
| Tempat Asal | Hebei, Tiongkok |
| Nomor Model | OEM |
| Nama Merek | Minfeng |
| Nama Produk | Konduktor Aluminium |
| Nomor Model | ACSR AAC AAAC |
| Konduktor | Konduktor Aluminium |
| Warna | Putih Perak |
| Standar | IEC 61089, DIN 48204, ASTM B232, BS215 |
| Sertifikat | ISO |
| Bahan | Aluminium |
| Selubung | Tanpa |
| Tipe | Kabel Telanjang |
| Kata Kunci | KONDUKTOR ALUMIN BAJA TERTANGGUH |
AAC terutama digunakan di daerah perkotaan di mana jaraknya pendek dan penyangganya berdekatan. Kelas AA untuk konduktor telanjang yang digunakan pada saluran udara. Konduktor Kelas A harus dilapisi dengan bahan tahan cuaca dan untuk konduktor telanjang di mana fleksibilitas yang lebih besar diperlukan.
Konduktor AAC AOGULI diproduksi sesuai dengan standar berikut:
- ASTM B230, NTC 360: Kawat Aluminium 1350-H19
- ASTM B231, NTC 308: Konduktor Aluminium 1350 Lilitan Konsentris
- IEC 228 untuk ukuran dalam mm²
| Nama Kode | Luas Total | Lilitan dan diameter kawat | Perkiraan Diameter Luar | Massa Linear | Beban Putus Nominal | Resistansi Maksimum pada 20℃ |
|---|---|---|---|---|---|---|
| Peachbell | 6 | 7/1.554 | 4.67 | 37 | 249 | 2.1692 |
| Rose | 4 | 7/1.961 | 5.89 | 58 | 396 | 1.3624 |
| Iris | 2 | 7/2.474 | 7.42 | 93 | 597 | 0.8577 |
| Pansy | 1 | 7/2.776 | 8.33 | 117 | 732 | 0.6801 |
| Pop | 1/0 | 7/3.119 | 9.36 | 147 | 873 | 0.5390 |
| Aster | 2/0 | 7/3.503 | 10.51 | 186 | 1100 | 0.4276 |
| Phlox | 3/0 | 7/3.932 | 11.80 | 234 | 1347 | 0.3390 |
| Oxlip | 4/0 | 7/4.417 | 13.26 | 296 | 1698 | 0.2688 |
| Valerian | 250 | 19/2.913 | 14.57 | 349 | 2062 | 0.2275 |
| Sneezewort | 250 | 7/4.80 | 14.40 | 349 | 2007 | 0.2275 |
| Laurel | 266.8 | 19/3.01 | 15.05 | 373 | 2200 | 0.2133 |
| Daisy | 266.8 | 7/4.96 | 14.90 | 373 | 2141 | 0.2133 |
| Peony | 300 | 19/3.193 | 15.97 | 419 | 2403 | 0.1896 |
| Tulip | 336.4 | 19/3.381 | 16.91 | 470 | 2695 | 0.1691 |
| Daffodil | 350 | 19/3.447 | 17.24 | 489 | 2804 | 0.1625 |
| Canna | 397.5 | 19/3.673 | 18.36 | 555 | 3184 | 0.1431 |
| Goldentuft | 450 | 19/3.909 | 19.55 | 629 | 3499 | 0.1264 |
Konduktor ACSR telah banyak digunakan pada saluran transmisi daya dengan berbagai tingkat tegangan, karena memiliki karakteristik yang baik seperti struktur sederhana, isolasi dan perawatan yang nyaman, biaya rendah, kapasitas transmisi besar. Dan juga cocok untuk penempatan di seberang sungai, lembah, dan tempat-tempat dengan fitur geografis khusus.
- ASTM B-232
- BS EN-50182
- CSAC 61089
- AS/NZS 3607
- DIN 48204
- IEC 61089
- GB/T 1179
- ASTM B711
| Luas | Lilitan dan diameter kawat | Diameter luar | Massa Linear | Beban putus nominal |
|---|---|---|---|---|
| 16/2.5 | 6/1.80 + 1/1.80 | 5.40 | 62 | 595 |
| 25/4.0 | 6/2.25 + 1/2.5 | 6.80 | 97 | 920 |
| 35/6.0 | 6/2.70 + 1/2.70 | 8.10 | 140 | 1265 |
| 44/32.0 | 14/2.00 + 7/2.40 | 11.20 | 372 | 4500 |
| 50/8.0 | 6/3.20 + 1/3.20 | 9.60 | 196 | 1710 |
| 50/30 | 12/2.33 + 7/2.33 | 11.70 | 378 | 4380 |
| 70/12 | 26/1.85 + 7/1.44 | 11.70 | 284 | 2680 |
| 95/15 | 26/2.15 + 7/1.67 | 13.60 | 383 | 3575 |
| 95/55 | 12/3.20 + 7/3.20 | 16.00 | 712 | 7935 |
| 105/75 | 14/3.10 + 9/2.25 | 17.50 | 891 | 10845 |
| 120/20 | 26/2.44 + 7/1.90 | 15.50 | 494 | 4565 |
| 120/70 | 12/3.60 + 7/3.60 | 18.00 | 90 | 10000 |
| 125/30 | 30/2.33 + 7/2.33 | 16.30 | 591 | 5760 |
| 150/25 | 26/2.70 + 7/2.10 | 17.10 | 605 | 5525 |
| 170/40 | 30/2.70 + 7/2.70 | 18.90 | 794 | 7675 |
| 185/30 | 26/3.00 + 7/2.33 | 19.00 | 746 | 6620 |
| 210/35 | 26/3.20 + 7/2.49 | 20.30 | 850 | 7490 |
| 210/50 | 30/3.00 + 7/3.00 | 21.00 | 981 | 9390 |
| 230/30 | 24/3.50 + 7/2.33 | 21.00 | 877 | 7310 |
| 240/40 | 26/3.45 + 7/2.68 | 21.90 | 987 | 8640 |
| 265/35 | 24/3.74 + 7/2.49 | 22.40 | 1002 | 8305 |
| 300/50 | 26/3.86 + 7/3.00 | 24.50 | 1236 | 10700 |
| 305/40 | 54/2.68 + 7/2.68 | 24.10 | 1160 | 9940 |
| 340/30 | 48/3.00 + 7/2.33 | 25.00 | 1180 | 9290 |
Konduktor ini dirancang untuk mendapatkan rasio kekuatan terhadap berat yang lebih baik dan menawarkan sifat listrik yang ditingkatkan, karakteristik sag-tension yang lebih baik, dan ketahanan korosi yang unggul jika dibandingkan dengan ACSR.
Konduktor Paduan Aluminium Semua (AAAC) dapat dipasok untuk memenuhi berbagai Standar Internasional sebagai berikut:
- IEC 61089
- ASTM B 399
- BS EN 50182
- DIN 48201 / 6
| Ukuran konduktor mm² | Luas paduan mm² | Jumlah kawat | Diameter kawat mm | Diameter luar konduktor mm | Massa linear kg/km | Kekuatan tarik terukur daN | Resistansi maksimum D.C. pada 20℃ Ω/km |
|---|---|---|---|---|---|---|---|
| 16 | 15.89 | 7 | 1.70 | 5.10 | 43 | 444 | 2.0910 |
| 25 | 24.25 | 7 | 2.10 | 6.30 | 66 | 677 | 1.3703 |
| 35 | 34.36 | 7 | 2.50 | 7.50 | 94 | 960 | 0.9669 |
| 50 | 49.48 | 7 | 3.00 | 9.00 | 135 | 1382 | 0.6714 |
| 50 | 48.35 | 19 | 1.80 | 9.00 | 133 | 1350 | 0.6905 |
| 70 | 65.81 | 19 | 2.10 | 10.50 | 181 | 1838 | 0.5073 |
| 95 | 93.27 | 19 | 2.50 | 12.50 | 256 | 2605 | 0.3579 |
| 120 | 116.99 | 19 | 2.80 | 14.00 | 322 | 3268 | 0.2854 |
| 150 | 147.11 | 37 | 2.25 | 15.80 | 406 | 4109 | 0.2274 |
| 185 | 181.62 | 37 | 2.50 | 17.50 | 500 | 5073 | 0.1842 |
| 240 | 242.54 | 61 | 2.25 | 20.30 | 670 | 6774 | 0.1383 |
| 300 | 299.43 | 61 | 2.50 | 22.50 | 827 | 8363 | 0.1120 |
| 400 | 400.14 | 61 | 2.89 | 26.00 | 1104 | 11176 | 0.0838 |
| 500 | 499.63 | 61 | 3.23 | 29.10 | 1379 | 13960 | 0.0671 |
| 625 | 626.2 | 91 | 2.96 | 32.60 | 1732 | 17490 | 0.0540 |
| 800 | 802.09 | 91 | 3.35 | 36.90 | 2218 | 22402 | 0.0418 |
| 1000 | 999.71 | 91 | 3.74 | 41.10 | 2767 | 27922 | 0.0335 |
-