Kabel ACSR Konduktor Aluminium Telanjang Tegangan Rendah Untuk Aplikasi Udara
| Exoprt Experience: | Amerika Selatan, Afrika, Timur Tengah dll | Conductor Shape: | Bundar |
| Free Sample: | Ya | Insulating Material: | Telanjang |
| Cores No: | 1-36 | Application: | Transmisi daya |
| Material Of Conductor: | Aluminium | ||
| High Light: | Konduktor Aluminium Telanjang,Konduktor Telanjang Di Atas,Konduktor Kabel ACSR |
||
| Bahan Konduktor | Kabel ACSR |
|---|---|
| Bahan Isolasi | Tidak ada bahan isolasi |
| Jaket | Tidak ada sarung |
| Aplikasi | Atas |
| Jenis | Tegangan Rendah |
| Tempat Asal | Hebei, Tiongkok |
| Nomor Model | OEM |
| Nama Merek | Minfeng |
| Nama Produk | Konduktor Aluminium |
| Nomor Model | ACSR AAC AAAC |
| Konduktor | Konduktor Aluminium |
| Warna | Perak putih |
| Standar | IEC 61089, DIN 48204, ASTM B232, BS215 |
| Sertifikat | ISO |
| Bahan | Aluminium |
| Jaket | Tanpa |
| Jenis | Kabel Telanjang |
| Kata kunci | BAJA Konduktor Aluminium DIPERKUAT |
AAC digunakan terutama di daerah perkotaan yang jaraknya pendek dan tumpuannya dekat. Kelas AA untuk konduktor telanjang yang digunakan pada saluran udara. Konduktor Kelas A harus dilapisi dengan bahan tahan cuaca dan untuk konduktor telanjang yang memerlukan fleksibilitas lebih besar.
Konduktor AOGULI AAC diproduksi sesuai dengan standar berikut:
- ASTM B230, NTC 360: Kawat Aluminium 1350-H19
- ASTM B231, NTC 308: Konduktor Aluminium 1350 Konsentris-Lay-Stranded
- IEC 228 untuk ukuran dalam mm²
| Nama Kode | Luas Total | Stranding dan diameter kawat | Perkiraan Diameter Keseluruhan | Massa Linier | Beban putus nominal | Resistansi Maksimum pada 20℃ |
|---|---|---|---|---|---|---|
| lonceng persik | 6 | 7/1.554 | 4.67 | 37 | 249 | 2.1692 |
| Mawar | 4 | 7/1.961 | 5.89 | 58 | 396 | 1.3624 |
| Iris | 2 | 7/2.474 | 7.42 | 93 | 597 | 0,8577 |
| Banci | 1 | 7/2.776 | 8.33 | 117 | 732 | 0,6801 |
| Pop | 1/0 | 7/3.119 | 9.36 | 147 | 873 | 0,5390 |
| Aster | 2/0 | 7/3.503 | 10.51 | 186 | 1100 | 0,4276 |
| Phlox | 3/0 | 7/3.932 | 11.80 | 234 | 1347 | 0,3390 |
| bibir sapi | 4/0 | 7/4.417 | 13.26 | 296 | 1698 | 0,2688 |
| Valerian | 250 | 19/2.913 | 14.57 | 349 | 2062 | 0,2275 |
| lumut bersin | 250 | 7/4.80 | 14.40 | 349 | 2007 | 0,2275 |
| Pohon salam | 266.8 | 19/3.01 | 15.05 | 373 | 2200 | 0,2133 |
| bunga aster | 266.8 | 7/4.96 | 14.90 | 373 | 2141 | 0,2133 |
| peoni | 300 | 19/3.193 | 15.97 | 419 | 2403 | 0,1896 |
| Bunga tulp | 336.4 | 19/3.381 | 16.91 | 470 | 2695 | 0,1691 |
| Bakung | 350 | 19/3.447 | 17.24 | 489 | 2804 | 0,1625 |
| ganja | 397,5 | 19/3.673 | 18.36 | 555 | 3184 | 0,1431 |
| tumpuan emas | 450 | 19/3.909 | 19.55 | 629 | 3499 | 0,1264 |
Konduktor ACSR telah banyak digunakan pada saluran transmisi tenaga listrik dengan berbagai level tegangan, karena memiliki karakteristik yang baik seperti struktur sederhana, isolasi dan perawatan yang mudah, serta kapasitas transmisi besar yang berbiaya rendah. Dan mereka juga cocok untuk diletakkan di seberang lembah sungai dan tempat-tempat di mana terdapat fitur geografis khusus.
- ASTM B-232
- BS EN-50182
- CSAC 61089
- AS/NZS 3607
- DIN 48204
- IEC 61089
- GB/T 1179
- ASTM B711
| Daerah | Berdiri dan diameter kawat | Diameter keseluruhan | Massa Linier | Beban putus nominal |
|---|---|---|---|---|
| 16/2.5 | 6/1,80 + 1/1,80 | 5.40 | 62 | 595 |
| 25/4.0 | 6/2.25 + 1/2.5 | 6.80 | 97 | 920 |
| 35/6.0 | 6/2.70 + 1/2.70 | 8.10 | 140 | 1265 |
| 44/32.0 | 14/2.00 + 7/2.40 | 11.20 | 372 | 4500 |
| 50/8.0 | 6/3.20 + 1/3.20 | 9.60 | 196 | 1710 |
| 50/30 | 12/2.33 + 7/2.33 | 11.70 | 378 | 4380 |
| 70/12 | 26/1.85 + 7/1.44 | 11.70 | 284 | 2680 |
| 95/15 | 26/2.15 + 7/1.67 | 13.60 | 383 | 3575 |
| 95/55 | 12/3.20 + 7/3.20 | 16.00 | 712 | 7935 |
| 105/75 | 14/3.10 + 9/2.25 | 17.50 | 891 | 10845 |
| 120/20 | 26/2.44 + 7/1.90 | 15.50 | 494 | 4565 |
| 120/70 | 12/3.60 + 7/3.60 | 18.00 | 90 | 10.000 |
| 125/30 | 30/2.33 + 7/2.33 | 16.30 | 591 | 5760 |
| 150/25 | 26/2.70 + 7/2.10 | 17.10 | 605 | 5525 |
| 170/40 | 30/2.70 + 7/2.70 | 18.90 | 794 | 7675 |
| 185/30 | 26/3.00 + 7/2.33 | 19.00 | 746 | 6620 |
| 210/35 | 26/3.20 + 7/2.49 | 20.30 | 850 | 7490 |
| 210/50 | 30/3.00 + 7/3.00 | 21.00 | 981 | 9390 |
| 230/30 | 24/3.50 + 7/2.33 | 21.00 | 877 | 7310 |
| 240/40 | 26/3.45 + 7/2.68 | 21.90 | 987 | 8640 |
| 265/35 | 24/3.74 + 7/2.49 | 22.40 | 1002 | 8305 |
| 300/50 | 26/3.86 + 7/3.00 | 24.50 | 1236 | 10700 |
| 305/40 | 54/2.68 + 7/2.68 | 24.10 | 1160 | 9940 |
| 340/30 | 48/3.00 + 7/2.33 | 25.00 | 1180 | 9290 |
Konduktor dirancang untuk mendapatkan rasio kekuatan terhadap berat yang lebih baik dan menawarkan sifat listrik yang lebih baik, karakteristik tegangan sag yang sangat baik, dan ketahanan korosi yang unggul jika dibandingkan dengan ACSR.
Semua Konduktor Paduan Aluminium (AAAC) dapat disuplai untuk memenuhi berbagai Standar Internasional sebagai berikut:
- IEC 61089
- ASTM B 399
- BS EN 50182
- DIN 48201/6
| Ukuran konduktor mm² | Luas paduan mm² | Jumlah kabel | Diameter kawat mm | Diameter keseluruhan konduktor mm | Massa linier kg/km | Nilai kekuatan tarik daN | Resistansi maksimum DC pada 20℃ Ω/km |
|---|---|---|---|---|---|---|---|
| 16 | 15.89 | 7 | 1.70 | 5.10 | 43 | 444 | 2.0910 |
| 25 | 24.25 | 7 | 2.10 | 6.30 | 66 | 677 | 1.3703 |
| 35 | 34.36 | 7 | 2.50 | 7.50 | 94 | 960 | 0,9669 |
| 50 | 49.48 | 7 | 3.00 | 9.00 | 135 | 1382 | 0,6714 |
| 50 | 48.35 | 19 | 1.80 | 9.00 | 133 | 1350 | 0,6905 |
| 70 | 65.81 | 19 | 2.10 | 10.50 | 181 | 1838 | 0,5073 |
| 95 | 93.27 | 19 | 2.50 | 12.50 | 256 | 2605 | 0,3579 |
| 120 | 116,99 | 19 | 2.80 | 14.00 | 322 | 3268 | 0,2854 |
| 150 | 147.11 | 37 | 2.25 | 15.80 | 406 | 4109 | 0,2274 |
| 185 | 181.62 | 37 | 2.50 | 17.50 | 500 | 5073 | 0,1842 |
| 240 | 242.54 | 61 | 2.25 | 20.30 | 670 | 6774 | 0,1383 |
| 300 | 299.43 | 61 | 2.50 | 22.50 | 827 | 8363 | 0,1120 |
| 400 | 400.14 | 61 | 2.89 | 26.00 | 1104 | 11176 | 0,0838 |
| 500 | 499.63 | 61 | 3.23 | 29.10 | 1379 | 13960 | 0,0671 |
| 625 | 626.2 | 91 | 2.96 | 32.60 | 1732 | 17490 | 0,0540 |
| 800 | 802.09 | 91 | 3.35 | 36.90 | 2218 | 22402 | 0,0418 |
| 1000 | 999.71 | 91 | 3.74 | 41.10 | 2767 | 27922 | 0,0335 |






-